Development Of Wireless Sensor Network For Monitoring Indoor Air Quality

It is an undeniable fact that air quality is vital in our daily lives. The contributing indoor air pollution at the workplace or in our residential areas has caught the attention of scientists and generally, the public in recent years. It is interesting to find that the studies done came up with...

全面介绍

Saved in:
书目详细资料
主要作者: Idris, Mohaiyedin
格式: Thesis
语言:English
出版: 2010
主题:
在线阅读:http://eprints.usm.my/41658/1/MOHAIYEDIN_IDRIS_HJ.pdf
标签: 添加标签
没有标签, 成为第一个标记此记录!
id my-usm-ep.41658
record_format uketd_dc
spelling my-usm-ep.416582019-04-12T05:26:46Z Development Of Wireless Sensor Network For Monitoring Indoor Air Quality 2010-10 Idris, Mohaiyedin TK Electrical Engineering. Electronics. Nuclear Engineering It is an undeniable fact that air quality is vital in our daily lives. The contributing indoor air pollution at the workplace or in our residential areas has caught the attention of scientists and generally, the public in recent years. It is interesting to find that the studies done came up with the discovery that the indoor air pollution contributes higher degree of air contaminants compared to the level of air pollution outdoor. This is probably explained by the fact that people tend to spend 90 % of their time indoor and the rest on outdoor activities. Unpolluted air furnishes us with good, comfortable, and healthy lifestyles which may lead to a productive working environment and at the same time, contribute to a better peace of mind. The approach of wireless sensor network is applied in order to detect and monitor the indoor air pollution. The air quality parameters such as air temperature, percentage of relative humidity, and air contaminants are carried out in this research. LM35DZ temperature sensor and A0545 humidity sensor are employed to measure air temperature and relative humidity in percentage. Based on these two measurements, dew point is obtained to measure the level of air temperature required to produce 100 % relative humidity. The TGS2600 semiconductor gas sensor is employed to detect air contaminants of carbon monoxide with 0.0188 mean square error. In this research, six nodes and a data handler are developed. Each sensor node consists of PIC16F877 microcontroller device with three sensors (temperature, humidity and gas sensors) and SRWF-508 transceiver module. All the sensor nodes are connected to the data handler through the star network to monitor air quality. 2010-10 Thesis http://eprints.usm.my/41658/ http://eprints.usm.my/41658/1/MOHAIYEDIN_IDRIS_HJ.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Kejuruteraan Elektrik & Elektronik
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic TK Electrical Engineering
Electronics
Nuclear Engineering
spellingShingle TK Electrical Engineering
Electronics
Nuclear Engineering
Idris, Mohaiyedin
Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
description It is an undeniable fact that air quality is vital in our daily lives. The contributing indoor air pollution at the workplace or in our residential areas has caught the attention of scientists and generally, the public in recent years. It is interesting to find that the studies done came up with the discovery that the indoor air pollution contributes higher degree of air contaminants compared to the level of air pollution outdoor. This is probably explained by the fact that people tend to spend 90 % of their time indoor and the rest on outdoor activities. Unpolluted air furnishes us with good, comfortable, and healthy lifestyles which may lead to a productive working environment and at the same time, contribute to a better peace of mind. The approach of wireless sensor network is applied in order to detect and monitor the indoor air pollution. The air quality parameters such as air temperature, percentage of relative humidity, and air contaminants are carried out in this research. LM35DZ temperature sensor and A0545 humidity sensor are employed to measure air temperature and relative humidity in percentage. Based on these two measurements, dew point is obtained to measure the level of air temperature required to produce 100 % relative humidity. The TGS2600 semiconductor gas sensor is employed to detect air contaminants of carbon monoxide with 0.0188 mean square error. In this research, six nodes and a data handler are developed. Each sensor node consists of PIC16F877 microcontroller device with three sensors (temperature, humidity and gas sensors) and SRWF-508 transceiver module. All the sensor nodes are connected to the data handler through the star network to monitor air quality.
format Thesis
qualification_level Master's degree
author Idris, Mohaiyedin
author_facet Idris, Mohaiyedin
author_sort Idris, Mohaiyedin
title Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_short Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_full Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_fullStr Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_full_unstemmed Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_sort development of wireless sensor network for monitoring indoor air quality
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Kejuruteraan Elektrik & Elektronik
publishDate 2010
url http://eprints.usm.my/41658/1/MOHAIYEDIN_IDRIS_HJ.pdf
_version_ 1747820951202955264