Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost Effectiveness
The lack of systems to disseminate information on the knowledge and technological characteristics of energy conservations, energy productions and energy usage in the construction industry has led to a publication of Malaysia Standard: Code of Practice on Energy Efficiency and Use of Renewable Energ...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2011
|
Subjects: | |
Online Access: | http://eprints.usm.my/42255/1/NURUL_AKMAM_NAAMANDADIN.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-usm-ep.42255 |
---|---|
record_format |
uketd_dc |
spelling |
my-usm-ep.422552019-04-12T05:26:33Z Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost Effectiveness 2011-06 Naamandadin, Nurul Akmam TH1-9745 Building construction The lack of systems to disseminate information on the knowledge and technological characteristics of energy conservations, energy productions and energy usage in the construction industry has led to a publication of Malaysia Standard: Code of Practice on Energy Efficiency and Use of Renewable Energy for Non-Residential Buildings (MS 1525:2007). This study was carried out with reference to the architectural and passive design strategy stated in MS 1525:2007. The assessments to the site planning and orientation, facade design, ventilation, strategic landscaping and future consideration of renewable energy were made on three selected energy efficient office buildings which are Securities Commission Building,Mesiniaga Tower and LEO Building. 2011-06 Thesis http://eprints.usm.my/42255/ http://eprints.usm.my/42255/1/NURUL_AKMAM_NAAMANDADIN.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Perumahan, Bangunan & Perancangan |
institution |
Universiti Sains Malaysia |
collection |
USM Institutional Repository |
language |
English |
topic |
TH1-9745 Building construction |
spellingShingle |
TH1-9745 Building construction Naamandadin, Nurul Akmam Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost Effectiveness |
description |
The lack of systems to disseminate information on the knowledge and technological characteristics of energy conservations, energy productions and energy usage in the
construction industry has led to a publication of Malaysia Standard: Code of Practice on Energy Efficiency and Use of Renewable Energy for Non-Residential Buildings
(MS 1525:2007). This study was carried out with reference to the architectural and passive design strategy stated in MS 1525:2007. The assessments to the site planning
and orientation, facade design, ventilation, strategic landscaping and future consideration of renewable energy were made on three selected energy efficient office buildings which are Securities Commission Building,Mesiniaga Tower and LEO Building. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Naamandadin, Nurul Akmam |
author_facet |
Naamandadin, Nurul Akmam |
author_sort |
Naamandadin, Nurul Akmam |
title |
Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost
Effectiveness
|
title_short |
Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost
Effectiveness
|
title_full |
Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost
Effectiveness
|
title_fullStr |
Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost
Effectiveness
|
title_full_unstemmed |
Evaluation Of Three Energy EfficientOffice Buildings On Architectural AndPassive Design Strategy Towards Cost
Effectiveness
|
title_sort |
evaluation of three energy efficientoffice buildings on architectural andpassive design strategy towards cost
effectiveness |
granting_institution |
Universiti Sains Malaysia |
granting_department |
Pusat Pengajian Perumahan, Bangunan & Perancangan |
publishDate |
2011 |
url |
http://eprints.usm.my/42255/1/NURUL_AKMAM_NAAMANDADIN.pdf |
_version_ |
1747821045337817088 |