Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies
X-ray fluorescence (XRF), which is a standard elemental analysis technique, was investigated for the purpose of measuring elements in vivo. An XRF system comprising of an excitation source, sample and a detection system in a 90° geometry was developed and optimized by simulations using the Monte Car...
محفوظ في:
المؤلف الرئيسي: | |
---|---|
التنسيق: | أطروحة |
اللغة: | English |
منشور في: |
2009
|
الموضوعات: | |
الوصول للمادة أونلاين: | http://eprints.usm.my/42829/1/WAN_SALWANI_JAAFAR.pdf |
الوسوم: |
إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
|
id |
my-usm-ep.42829 |
---|---|
record_format |
uketd_dc |
spelling |
my-usm-ep.428292019-04-12T05:27:00Z Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies 2009-06 Jaafar, Wan Salwani QC1 Physics (General) X-ray fluorescence (XRF), which is a standard elemental analysis technique, was investigated for the purpose of measuring elements in vivo. An XRF system comprising of an excitation source, sample and a detection system in a 90° geometry was developed and optimized by simulations using the Monte Carlo code, Monte Carlo N-Particle version 5 (MCNP5). For optimal use, the grazing angle of the sample is at 15° and the source-to-sample distance (SSD) and sample-to-detector distance (SDD) were at minimum values. For experimental verification, a physical system almost similar to the simulated system was set up at the Biophysics Laboratory, School of Physics, USM 2009-06 Thesis http://eprints.usm.my/42829/ http://eprints.usm.my/42829/1/WAN_SALWANI_JAAFAR.pdf application/pdf en public phd doctoral Universiti Sains Malaysia Pusat Pengajian Sains Fizik |
institution |
Universiti Sains Malaysia |
collection |
USM Institutional Repository |
language |
English |
topic |
QC1 Physics (General) |
spellingShingle |
QC1 Physics (General) Jaafar, Wan Salwani Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies |
description |
X-ray fluorescence (XRF), which is a standard elemental analysis technique, was investigated for the purpose of measuring elements in vivo. An XRF system comprising of an excitation source, sample and a detection system in a 90° geometry was developed and optimized by simulations using the Monte Carlo code, Monte Carlo N-Particle version 5 (MCNP5). For optimal use, the grazing angle of the sample is at 15° and the source-to-sample distance (SSD) and sample-to-detector distance (SDD) were at minimum values. For experimental verification, a physical system almost similar to the simulated system was set up at the Biophysics Laboratory, School of Physics, USM |
format |
Thesis |
qualification_name |
Doctor of Philosophy (PhD.) |
qualification_level |
Doctorate |
author |
Jaafar, Wan Salwani |
author_facet |
Jaafar, Wan Salwani |
author_sort |
Jaafar, Wan Salwani |
title |
Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies |
title_short |
Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies |
title_full |
Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies |
title_fullStr |
Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies |
title_full_unstemmed |
Development And Assessment Of An X-Ray Fluorescence System For In Vivo Studies |
title_sort |
development and assessment of an x-ray fluorescence system for in vivo studies |
granting_institution |
Universiti Sains Malaysia |
granting_department |
Pusat Pengajian Sains Fizik |
publishDate |
2009 |
url |
http://eprints.usm.my/42829/1/WAN_SALWANI_JAAFAR.pdf |
_version_ |
1747821109731917824 |