Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection

Everyday inventions of microelectronics and micro-devices are advancing towards converting the Microchip Capillary Electrophoresis (MCE) devices into a true Micro Total Analysis System (μTAS) or Lab-On-a-Chip (LOC) microsystem that can perform the whole analytical procedures in-situ. Electrochemical...

Full description

Saved in:
Bibliographic Details
Main Author: Ghanim, Motasem H H
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.usm.my/43838/1/Motasem%20H%20H%20Ghanim24.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.43838
record_format uketd_dc
spelling my-usm-ep.438382019-04-12T05:26:10Z Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection 2013-08 Ghanim, Motasem H H TK1-9971 Electrical engineering. Electronics. Nuclear engineering Everyday inventions of microelectronics and micro-devices are advancing towards converting the Microchip Capillary Electrophoresis (MCE) devices into a true Micro Total Analysis System (μTAS) or Lab-On-a-Chip (LOC) microsystem that can perform the whole analytical procedures in-situ. Electrochemical detection (ECD) is one of the best means for designing a LOC or μTAS systems especially for separation and detection of electroactive analytes, as in biomedical and in vitro diagnostics. The most widely targeted electroactive analytes is nucleic acid. DNA genotyping or fingerprinting has been recognized as one of the most important applications of these micro devices. DNA fingerprinting is normally used in electrophoretic applications of analytical chemistry such as DNA sequencing and detection, identification of pathogenic microorganism like microbe fungus, and disease diagnostics. However, there are some major obstacles in realizing miniaturized and mass-producible MCE systems, such as high manufacturing cost, and the bulky power supply unit which make the whole system none-portable. In this project, a low cost as well as low electric field MCE utilizing an amperometric detection scheme was designed and fabricated for DNA sequencing and detection. The device was fabricated from a glass/polydimethylsiloxane (PDMS) hybrid engraved microchannel with platinum electrodes sputtered onto a glass substrate. It has been established that, the use of Agarose gel as separation material could reduce the electric field to as low as 12 V/cm; this has not been achieved previously. 2013-08 Thesis http://eprints.usm.my/43838/ http://eprints.usm.my/43838/1/Motasem%20H%20H%20Ghanim24.pdf application/pdf en public phd doctoral Universiti Sains Malaysia Pusat Pengajian Kejuruteraan Elektrik & Elektronik
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic TK1-9971 Electrical engineering
Electronics
Nuclear engineering
spellingShingle TK1-9971 Electrical engineering
Electronics
Nuclear engineering
Ghanim, Motasem H H
Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection
description Everyday inventions of microelectronics and micro-devices are advancing towards converting the Microchip Capillary Electrophoresis (MCE) devices into a true Micro Total Analysis System (μTAS) or Lab-On-a-Chip (LOC) microsystem that can perform the whole analytical procedures in-situ. Electrochemical detection (ECD) is one of the best means for designing a LOC or μTAS systems especially for separation and detection of electroactive analytes, as in biomedical and in vitro diagnostics. The most widely targeted electroactive analytes is nucleic acid. DNA genotyping or fingerprinting has been recognized as one of the most important applications of these micro devices. DNA fingerprinting is normally used in electrophoretic applications of analytical chemistry such as DNA sequencing and detection, identification of pathogenic microorganism like microbe fungus, and disease diagnostics. However, there are some major obstacles in realizing miniaturized and mass-producible MCE systems, such as high manufacturing cost, and the bulky power supply unit which make the whole system none-portable. In this project, a low cost as well as low electric field MCE utilizing an amperometric detection scheme was designed and fabricated for DNA sequencing and detection. The device was fabricated from a glass/polydimethylsiloxane (PDMS) hybrid engraved microchannel with platinum electrodes sputtered onto a glass substrate. It has been established that, the use of Agarose gel as separation material could reduce the electric field to as low as 12 V/cm; this has not been achieved previously.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Ghanim, Motasem H H
author_facet Ghanim, Motasem H H
author_sort Ghanim, Motasem H H
title Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection
title_short Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection
title_full Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection
title_fullStr Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection
title_full_unstemmed Development Of A Low Electric Field Dna Electrophoresis Microchip Featuring Amperometric Detection
title_sort development of a low electric field dna electrophoresis microchip featuring amperometric detection
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Kejuruteraan Elektrik & Elektronik
publishDate 2013
url http://eprints.usm.my/43838/1/Motasem%20H%20H%20Ghanim24.pdf
_version_ 1747821288112521216