Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings

The excessive usage of air-conditioning to cool internal room in a building for human thermal comfort is harming our planet due to their hazardous refrigerants and the high energy consumption nature of these cooling systems. Hence replacement of these systems with the Peltier Cooling Device (P...

Full description

Saved in:
Bibliographic Details
Main Author: Seifi, Molood
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.usm.my/45151/1/Molood%20Seifi24.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.45151
record_format uketd_dc
spelling my-usm-ep.451512019-08-01T08:53:25Z Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings 2013-07 Seifi, Molood TH1-9745 Building construction The excessive usage of air-conditioning to cool internal room in a building for human thermal comfort is harming our planet due to their hazardous refrigerants and the high energy consumption nature of these cooling systems. Hence replacement of these systems with the Peltier Cooling Device (PCDs) which are more environmental friendly is highly encouraged. However, the application of PCDs in Buildings has remained minimal as they have limited cooling capacities that reduces the ability of the device in generating cooling effect and causing temperature reduction in enclosed spaces. Thus the present study seeks to improve the temperature reduction by the Peltier Cooling Device through an appropriate application strategy so that they can be used for reducing the temperature of buildings internal spaces. The data analysis of physical experiments revealed that there is a temperature reduction improvement of 0.75-0.78 °C by each PCD operating on the internal room when the overall building temperature is dropped by 5 °C in the application strategy two (AS2). Hence this strategy is the appropriate one to enhance the ability of the device in reducing the temperature reduction of the internal room. Moreover the Malaysian thermal comfort (MTC) for each cubic meter of the building internal spaces could be fulfilled with one to five modules of PCDs in normal room temperature up to 32 ° C; while the MTC can be achieved for internal spaces of higher temperature range 33 ° C – 37 ° C when the overall room temperature is dropped by 5 ° C with the assistance of any type of cooling system, likewise the application strategy two. 2013-07 Thesis http://eprints.usm.my/45151/ http://eprints.usm.my/45151/1/Molood%20Seifi24.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Perumahan, Banggunan & Perancangan
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic TH1-9745 Building construction
spellingShingle TH1-9745 Building construction
Seifi, Molood
Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
description The excessive usage of air-conditioning to cool internal room in a building for human thermal comfort is harming our planet due to their hazardous refrigerants and the high energy consumption nature of these cooling systems. Hence replacement of these systems with the Peltier Cooling Device (PCDs) which are more environmental friendly is highly encouraged. However, the application of PCDs in Buildings has remained minimal as they have limited cooling capacities that reduces the ability of the device in generating cooling effect and causing temperature reduction in enclosed spaces. Thus the present study seeks to improve the temperature reduction by the Peltier Cooling Device through an appropriate application strategy so that they can be used for reducing the temperature of buildings internal spaces. The data analysis of physical experiments revealed that there is a temperature reduction improvement of 0.75-0.78 °C by each PCD operating on the internal room when the overall building temperature is dropped by 5 °C in the application strategy two (AS2). Hence this strategy is the appropriate one to enhance the ability of the device in reducing the temperature reduction of the internal room. Moreover the Malaysian thermal comfort (MTC) for each cubic meter of the building internal spaces could be fulfilled with one to five modules of PCDs in normal room temperature up to 32 ° C; while the MTC can be achieved for internal spaces of higher temperature range 33 ° C – 37 ° C when the overall room temperature is dropped by 5 ° C with the assistance of any type of cooling system, likewise the application strategy two.
format Thesis
qualification_level Master's degree
author Seifi, Molood
author_facet Seifi, Molood
author_sort Seifi, Molood
title Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_short Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_full Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_fullStr Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_full_unstemmed Effectiveness Of Peltier Cooling Device In Reducing The Air Temperature Of Rooms In Buildings
title_sort effectiveness of peltier cooling device in reducing the air temperature of rooms in buildings
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Perumahan, Banggunan & Perancangan
publishDate 2013
url http://eprints.usm.my/45151/1/Molood%20Seifi24.pdf
_version_ 1747821459783286784