Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children

Background: Rapid establishment of children body weight is crucial for resuscitation as it enables calculation of drug doses, amount of fluid to be administered, and amount of energy to be applied. Actual weight is impractical to measure in a critically ill child. This study aims to compare the...

Full description

Saved in:
Bibliographic Details
Main Author: Wil, Fairuz Ramadanu Che
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.usm.my/45876/1/Dr.%20Fairuz%20Ramadanu%20Che%20Wil-24%20pages.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.45876
record_format uketd_dc
spelling my-usm-ep.458762020-01-13T04:43:42Z Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children 2018 Wil, Fairuz Ramadanu Che RJ Pediatrics Background: Rapid establishment of children body weight is crucial for resuscitation as it enables calculation of drug doses, amount of fluid to be administered, and amount of energy to be applied. Actual weight is impractical to measure in a critically ill child. This study aims to compare the accuracy of Advanced Paediatric Life Support (APLS) formula, APLS normal range table and the Broselow Paediatric Tape. Methods: Participant were selected from children from one to five point nine years old attending the Accident and Emergency department and Paediatric follow up clinic in Hospital University Sains Malaysia, Kelantan, and Paediatric and general clinics in Institut Perubatan dan Pergigian Termaju, Penang. Demographic characteristics were obtained. Weight and height of each child were measured using a calibrated scale and measuring tape. Estimated weights were later determined by using the APLS formula, the APLS table and the Broselow tape. The primary outcome was the accuracy within 10% of the measured weight. Results: The number of children included in this study were 464. There were 239(51.5%) boys and 225(48.5%) girls. All three methods overestimated the weight of the children with the APLS formula overestimating 64.9%, the APLS table 61.4% and the Broselow tape62% of them. However, the Broselow tape is the most accurate tool with 33% of the estimation within 10% of the actual weight, followed by the APLS table (29.5%) and the APLS formula (26.5%). The Broselow tape overestimated the weight with a mean difference of 14.79%(95% limits of agreement 47.1 to -17.5), the APLS table with 15.32%(95% limits of agreement 54.8 to -24.2) and the APLS formula with 17.48%(95% limits of agreement 59.4 to -24.4). Conclusions: The three methods consistently overestimated the weight. The Broselow tape appeared to be the most accurate out of them. The more recent APLS group recommendation, APLS table is more accurate than the APLS formula. 2018 Thesis http://eprints.usm.my/45876/ http://eprints.usm.my/45876/1/Dr.%20Fairuz%20Ramadanu%20Che%20Wil-24%20pages.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Perubatan
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic RJ Pediatrics
spellingShingle RJ Pediatrics
Wil, Fairuz Ramadanu Che
Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children
description Background: Rapid establishment of children body weight is crucial for resuscitation as it enables calculation of drug doses, amount of fluid to be administered, and amount of energy to be applied. Actual weight is impractical to measure in a critically ill child. This study aims to compare the accuracy of Advanced Paediatric Life Support (APLS) formula, APLS normal range table and the Broselow Paediatric Tape. Methods: Participant were selected from children from one to five point nine years old attending the Accident and Emergency department and Paediatric follow up clinic in Hospital University Sains Malaysia, Kelantan, and Paediatric and general clinics in Institut Perubatan dan Pergigian Termaju, Penang. Demographic characteristics were obtained. Weight and height of each child were measured using a calibrated scale and measuring tape. Estimated weights were later determined by using the APLS formula, the APLS table and the Broselow tape. The primary outcome was the accuracy within 10% of the measured weight. Results: The number of children included in this study were 464. There were 239(51.5%) boys and 225(48.5%) girls. All three methods overestimated the weight of the children with the APLS formula overestimating 64.9%, the APLS table 61.4% and the Broselow tape62% of them. However, the Broselow tape is the most accurate tool with 33% of the estimation within 10% of the actual weight, followed by the APLS table (29.5%) and the APLS formula (26.5%). The Broselow tape overestimated the weight with a mean difference of 14.79%(95% limits of agreement 47.1 to -17.5), the APLS table with 15.32%(95% limits of agreement 54.8 to -24.2) and the APLS formula with 17.48%(95% limits of agreement 59.4 to -24.4). Conclusions: The three methods consistently overestimated the weight. The Broselow tape appeared to be the most accurate out of them. The more recent APLS group recommendation, APLS table is more accurate than the APLS formula.
format Thesis
qualification_level Master's degree
author Wil, Fairuz Ramadanu Che
author_facet Wil, Fairuz Ramadanu Che
author_sort Wil, Fairuz Ramadanu Che
title Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children
title_short Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children
title_full Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children
title_fullStr Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children
title_full_unstemmed Accuracy of the APLS formula, the APLS normal range method and the broselow paediatric tape in estimating the body weight of Malaysian children
title_sort accuracy of the apls formula, the apls normal range method and the broselow paediatric tape in estimating the body weight of malaysian children
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Perubatan
publishDate 2018
url http://eprints.usm.my/45876/1/Dr.%20Fairuz%20Ramadanu%20Che%20Wil-24%20pages.pdf
_version_ 1747821583282470912