Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment

Nasopharynx cancer (NPC)’s tumour volume located at the head and neck which nearby with bundles of organ at risk (OAR). Therefore, it is important to have radiotherapy dose verification prior to the treatment. This is to make sure adequate dose delivered to tumour volume whereas protect well to orga...

Full description

Saved in:
Bibliographic Details
Main Author: Eng, Kae Yann
Format: Thesis
Language:English
Published: 2017
Subjects:
Online Access:http://eprints.usm.my/47521/1/ENG%20KAE%20YANN.pdf%20cut.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.47521
record_format uketd_dc
spelling my-usm-ep.475212020-10-22T03:03:09Z Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment 2017-10 Eng, Kae Yann QC1 Physics (General) Nasopharynx cancer (NPC)’s tumour volume located at the head and neck which nearby with bundles of organ at risk (OAR). Therefore, it is important to have radiotherapy dose verification prior to the treatment. This is to make sure adequate dose delivered to tumour volume whereas protect well to organ at risk. Dosimetry response of both Metal Oxide Semiconductor Field Effect Transistor (MOSFET) and Radiochromic EBT2 film were characterised before the dose verification of radiotherapy treatment was conducted. The characterisation of Radiochromic EBT2 film was ruled out from the tests which contributed combined standard uncertainty 5.05%. Tests are film reproducibility (0.25%), film darkening effect (0.25%), field size dependence (4.98%), and angular dependence (2.01%). Seven experiments were undergone to contribute 3.48% combined standard uncertainty for MOSFET. The experiments are MOSFET reproducibility (1.36%), fading effect (2.00%), perturbation (2.58%), linearity (2.88%), field size dependence (2.90%), angular dependence (3.36%), SSD dependence (2.59%). After the characterisation of Radiochromic EBT2 film and MOSFET, treatment plan dose verification was conducted in vitro. It showed a trend that measured doses higher than calculated doses by Treatment Planning System (TPS). TPS doses verified both dosimeters doses within 10% variation. Thus, both Radiochromic EBT2 film and MOSFET were suitable to be used as radiotherapy 2017-10 Thesis http://eprints.usm.my/47521/ http://eprints.usm.my/47521/1/ENG%20KAE%20YANN.pdf%20cut.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Fizik (School of Physics)
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic QC1 Physics (General)
spellingShingle QC1 Physics (General)
Eng, Kae Yann
Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment
description Nasopharynx cancer (NPC)’s tumour volume located at the head and neck which nearby with bundles of organ at risk (OAR). Therefore, it is important to have radiotherapy dose verification prior to the treatment. This is to make sure adequate dose delivered to tumour volume whereas protect well to organ at risk. Dosimetry response of both Metal Oxide Semiconductor Field Effect Transistor (MOSFET) and Radiochromic EBT2 film were characterised before the dose verification of radiotherapy treatment was conducted. The characterisation of Radiochromic EBT2 film was ruled out from the tests which contributed combined standard uncertainty 5.05%. Tests are film reproducibility (0.25%), film darkening effect (0.25%), field size dependence (4.98%), and angular dependence (2.01%). Seven experiments were undergone to contribute 3.48% combined standard uncertainty for MOSFET. The experiments are MOSFET reproducibility (1.36%), fading effect (2.00%), perturbation (2.58%), linearity (2.88%), field size dependence (2.90%), angular dependence (3.36%), SSD dependence (2.59%). After the characterisation of Radiochromic EBT2 film and MOSFET, treatment plan dose verification was conducted in vitro. It showed a trend that measured doses higher than calculated doses by Treatment Planning System (TPS). TPS doses verified both dosimeters doses within 10% variation. Thus, both Radiochromic EBT2 film and MOSFET were suitable to be used as radiotherapy
format Thesis
qualification_level Master's degree
author Eng, Kae Yann
author_facet Eng, Kae Yann
author_sort Eng, Kae Yann
title Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment
title_short Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment
title_full Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment
title_fullStr Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment
title_full_unstemmed Feasibility Of Using Ebt2 Radiochromic Film And Mosfet For Radiotherapy Dose Measurement In Nasopharynx Cancer Treatment
title_sort feasibility of using ebt2 radiochromic film and mosfet for radiotherapy dose measurement in nasopharynx cancer treatment
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Fizik (School of Physics)
publishDate 2017
url http://eprints.usm.my/47521/1/ENG%20KAE%20YANN.pdf%20cut.pdf
_version_ 1747821795066511360