A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients

The objective of this study is to determine relationship ofVascular Pedicle Width (VPW), Central Venous Pressure (CVP), Positive End Expiratory Pressure (PEEP) and Peak Inspiratory Pressure (PIP) in adult ventilated patients using single supine chest radiograph. This was prospective, randomized s...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Fahmi, Lukman
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:http://eprints.usm.my/52260/1/DR.%20MOHD%20FAHMI%20BIN%20LUKMAN%20-%2024%20pages.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.52260
record_format uketd_dc
spelling my-usm-ep.522602022-04-11T04:15:40Z A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients 2008 Mohd Fahmi, Lukman R Medicine (General) The objective of this study is to determine relationship ofVascular Pedicle Width (VPW), Central Venous Pressure (CVP), Positive End Expiratory Pressure (PEEP) and Peak Inspiratory Pressure (PIP) in adult ventilated patients using single supine chest radiograph. This was prospective, randomized study and had been approved by the Research and Ethics Committee, School Of Medical Sciences, Universiti Sains Malaysia. One-hundred and forty adult ventilated patients in Intensive Care Unit (ICU) and Neuroscience Intensive Care Unit of Hospital Universiti Sains Malaysia (HUSM) involved, from May 2006 until December 2006. CVP, PEEP and PIP was taken within 1 hour after chest radiograph taken. VPW was measured on digitalized chest radiograph by Radiology Researcher at separate occasion without clinical data related to patient's condition. There was a significant linear relationship between CVP and VPW (p<0.001, CI 0.48- 0.97 mmHg), with those who had CVP of 10 mmHg will have VPW wider for 7 .3mm. There was also significant linear relationship between PEEP and VPW {p<0.05, CI 0.00-0.97 cmH20) with those who had PEEP of 10 em H20 have VPW wider for 4.9mm. However, there was no significant linear relationship between PIP and VPW. There was no interaction between independent variables. From these three variables, CVP has a strongest correlation with VPW, which indicate it's usefulness in ICU. PEEP and PIP, served as ventilator parameters, have weaker relationship with VPW which makes implementation of VPW in ventilated patient regardless of ventilator setting become valuable. 2008 Thesis http://eprints.usm.my/52260/ http://eprints.usm.my/52260/1/DR.%20MOHD%20FAHMI%20BIN%20LUKMAN%20-%2024%20pages.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Perubatan
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Mohd Fahmi, Lukman
A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients
description The objective of this study is to determine relationship ofVascular Pedicle Width (VPW), Central Venous Pressure (CVP), Positive End Expiratory Pressure (PEEP) and Peak Inspiratory Pressure (PIP) in adult ventilated patients using single supine chest radiograph. This was prospective, randomized study and had been approved by the Research and Ethics Committee, School Of Medical Sciences, Universiti Sains Malaysia. One-hundred and forty adult ventilated patients in Intensive Care Unit (ICU) and Neuroscience Intensive Care Unit of Hospital Universiti Sains Malaysia (HUSM) involved, from May 2006 until December 2006. CVP, PEEP and PIP was taken within 1 hour after chest radiograph taken. VPW was measured on digitalized chest radiograph by Radiology Researcher at separate occasion without clinical data related to patient's condition. There was a significant linear relationship between CVP and VPW (p<0.001, CI 0.48- 0.97 mmHg), with those who had CVP of 10 mmHg will have VPW wider for 7 .3mm. There was also significant linear relationship between PEEP and VPW {p<0.05, CI 0.00-0.97 cmH20) with those who had PEEP of 10 em H20 have VPW wider for 4.9mm. However, there was no significant linear relationship between PIP and VPW. There was no interaction between independent variables. From these three variables, CVP has a strongest correlation with VPW, which indicate it's usefulness in ICU. PEEP and PIP, served as ventilator parameters, have weaker relationship with VPW which makes implementation of VPW in ventilated patient regardless of ventilator setting become valuable.
format Thesis
qualification_level Master's degree
author Mohd Fahmi, Lukman
author_facet Mohd Fahmi, Lukman
author_sort Mohd Fahmi, Lukman
title A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients
title_short A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients
title_full A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients
title_fullStr A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients
title_full_unstemmed A prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients
title_sort prospective study of relationship of vascular pedicle width and central venous pressure with ventilator parameters in ventilated patients
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Perubatan
publishDate 2008
url http://eprints.usm.my/52260/1/DR.%20MOHD%20FAHMI%20BIN%20LUKMAN%20-%2024%20pages.pdf
_version_ 1747822154689282048