Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan

Ambulance response time is the key performance for ambulances services. The objective of this study is to determine the factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia. This was a cross sectional study conducted in Emergency Department Hospital Univer...

Full description

Saved in:
Bibliographic Details
Main Author: Di, Teo Sin
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.usm.my/56400/1/Dr.%20Teo%20Sin%20Di-24%20pages.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.56400
record_format uketd_dc
spelling my-usm-ep.564002023-01-18T08:16:07Z Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan 2018 Di, Teo Sin R Medicine Ambulance response time is the key performance for ambulances services. The objective of this study is to determine the factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia. This was a cross sectional study conducted in Emergency Department Hospital Universiti Sains Malaysia between January 2016 to January 2017. A total of 300 samples had been collected by ambulance paramedic using validated ambulance form ‘Borang Sela Masa Tindak Balas Ambulans’. All ambulance forms with missing data were excluded in this study. Of 300 cases of emergency ambulance call cases, there were 254 cases (84.7%) of delayed ambulance response time. Current ambulance response time is 14 minutes with interquartile range of 5 minutes. Factors which showed significant association delayed ambulance response time include distance, location type and ambulance mechanism. The odd of delayed ambulance response time by every increase in distance unit was 1.59 (95% CI, 1.37 to 1.85). For location type, the odd of delayed ambulance response time for public location as compared to road was 0.13 (95% CI, 0.04 to 0.45). For ambulance mechanism, the odd of delayed ambulance response time for beacon type as compared to siren type was 0.22 (95% CI, 0.01 to 0.69). Distance, location type and ambulance mechanism showed significant association with delayed ambulance response time. Further intervention should be derived to improve current ambulance response time. 2018 Thesis http://eprints.usm.my/56400/ http://eprints.usm.my/56400/1/Dr.%20Teo%20Sin%20Di-24%20pages.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Perubatan
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic R Medicine
spellingShingle R Medicine
Di, Teo Sin
Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan
description Ambulance response time is the key performance for ambulances services. The objective of this study is to determine the factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia. This was a cross sectional study conducted in Emergency Department Hospital Universiti Sains Malaysia between January 2016 to January 2017. A total of 300 samples had been collected by ambulance paramedic using validated ambulance form ‘Borang Sela Masa Tindak Balas Ambulans’. All ambulance forms with missing data were excluded in this study. Of 300 cases of emergency ambulance call cases, there were 254 cases (84.7%) of delayed ambulance response time. Current ambulance response time is 14 minutes with interquartile range of 5 minutes. Factors which showed significant association delayed ambulance response time include distance, location type and ambulance mechanism. The odd of delayed ambulance response time by every increase in distance unit was 1.59 (95% CI, 1.37 to 1.85). For location type, the odd of delayed ambulance response time for public location as compared to road was 0.13 (95% CI, 0.04 to 0.45). For ambulance mechanism, the odd of delayed ambulance response time for beacon type as compared to siren type was 0.22 (95% CI, 0.01 to 0.69). Distance, location type and ambulance mechanism showed significant association with delayed ambulance response time. Further intervention should be derived to improve current ambulance response time.
format Thesis
qualification_level Master's degree
author Di, Teo Sin
author_facet Di, Teo Sin
author_sort Di, Teo Sin
title Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan
title_short Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan
title_full Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan
title_fullStr Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan
title_full_unstemmed Factors associated with delayed ambulance response time in Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan
title_sort factors associated with delayed ambulance response time in hospital universiti sains malaysia, kubang kerian, kelantan
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Perubatan
publishDate 2018
url http://eprints.usm.my/56400/1/Dr.%20Teo%20Sin%20Di-24%20pages.pdf
_version_ 1776101162798284800