Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer
Following successful precision and timing accuracy phases, the next step is a comprehensive evaluation of the web application versus the Microsoft Excel template. Testing with clinical data ensures robustness. Documentation and training for medical physicists are essential. Implementation will start...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2024
|
Subjects: | |
Online Access: | http://eprints.usm.my/61333/1/Haziq%20Asyraaf%20Shafizan-E.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-usm-ep.61333 |
---|---|
record_format |
uketd_dc |
spelling |
my-usm-ep.613332024-11-14T02:14:27Z Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer 2024-07 Shafizan, Haziq Asyraaf R Medicine RC254-282 Neoplasms. Tumors. Oncology (including Cancer) RC870-923 Diseases of the genitourinary system. Urology Following successful precision and timing accuracy phases, the next step is a comprehensive evaluation of the web application versus the Microsoft Excel template. Testing with clinical data ensures robustness. Documentation and training for medical physicists are essential. Implementation will start with a pilot group, followed by full-scale deployment. Evaluation of BED and EQD2 values reveals minimal deviations, indicating high comparability. For target tissue, BED deviation is 0.048% and EQD2 is 0.008%. The bladder shows a BED deviation of 0.055% and EQD2 of 0.073%. The rectum has a BED deviation of 0.014% and EQD2 of 0.029%. For the sigmoid, the BED deviation is 0.035% and EQD2 is 0.142%. All deviations are within the 3% tolerance limit. The web application completes the full treatment in 138.69 seconds, compared to 202.67 seconds for Excel, with a TER of 1.46. For the first additional patient, the web application takes 96.84 seconds, while Excel takes 107.11 seconds, giving a TER of 1.11. For the second additional patient, the web application takes 94.77 seconds versus 78.66 seconds for Excel, with a TER of 0.83. Despite occasional exceptions, the web application is generally more time-efficient and reliable. 2024-07 Thesis http://eprints.usm.my/61333/ http://eprints.usm.my/61333/1/Haziq%20Asyraaf%20Shafizan-E.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Kesihatan |
institution |
Universiti Sains Malaysia |
collection |
USM Institutional Repository |
language |
English |
topic |
R Medicine R Medicine R Medicine |
spellingShingle |
R Medicine R Medicine R Medicine Shafizan, Haziq Asyraaf Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer |
description |
Following successful precision and timing accuracy phases, the next step is a comprehensive evaluation of the web application versus the Microsoft Excel template. Testing with clinical data ensures robustness. Documentation and training for medical physicists are essential. Implementation will start with a pilot group, followed by full-scale deployment. Evaluation of BED and EQD2 values reveals minimal deviations, indicating high comparability. For target tissue, BED deviation is 0.048% and EQD2 is 0.008%. The bladder shows a BED deviation of 0.055% and EQD2 of 0.073%. The rectum has a BED deviation of 0.014% and EQD2 of 0.029%. For the sigmoid, the BED deviation is 0.035% and EQD2 is 0.142%. All deviations are within the 3% tolerance limit. The web application completes the full treatment in 138.69 seconds, compared to 202.67 seconds for Excel, with a TER of 1.46. For the first additional patient, the web application takes 96.84 seconds, while Excel takes 107.11 seconds, giving a TER of 1.11. For the second additional patient, the web application takes 94.77 seconds versus 78.66 seconds for Excel, with a TER of 0.83. Despite occasional exceptions, the web application is generally more time-efficient and reliable. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Shafizan, Haziq Asyraaf |
author_facet |
Shafizan, Haziq Asyraaf |
author_sort |
Shafizan, Haziq Asyraaf |
title |
Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer |
title_short |
Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer |
title_full |
Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer |
title_fullStr |
Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer |
title_full_unstemmed |
Evaluation of high-dose rate (HDR) radiobiologic dose-equivalent web tool for cervical cancer |
title_sort |
evaluation of high-dose rate (hdr) radiobiologic dose-equivalent web tool for cervical cancer |
granting_institution |
Universiti Sains Malaysia |
granting_department |
Pusat Pengajian Sains Kesihatan |
publishDate |
2024 |
url |
http://eprints.usm.my/61333/1/Haziq%20Asyraaf%20Shafizan-E.pdf |
_version_ |
1818647397763383296 |