Centralized Database System For Automated Hearing Screening

Centralized database software enables simultaneous updates from multiple queries containing data from different machines. It enables the data to be stored safely in a centralized location. Based on the related research work on PC based Automated Hearing Screening kit which store the test results in...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Saad, Hamid
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/16214/1/Centralized%20Database%20System%20For%20Automated%20Hearing%20Screening%2024%20Pages.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utem-ep.16214
record_format uketd_dc
spelling my-utem-ep.162142016-04-12T03:48:21Z Centralized Database System For Automated Hearing Screening 2014 Mohd Saad, Hamid Q Science (General) QA76 Computer software Centralized database software enables simultaneous updates from multiple queries containing data from different machines. It enables the data to be stored safely in a centralized location. Based on the related research work on PC based Automated Hearing Screening kit which store the test results in local storage, it may have problem to perform the data collection from different location of test centers. The main objective of this project is to extend the capabilities of the kit into centralized database architecture for easy access of the test results from multiple test centers locations. The proposed methods used in this project involved database structure design through user requirements analysis, defining data type for each entities and modeling the database using entity relationship diagram (ERD). Web application interface has been proposed in this project as a method to extract the test results from the database. The PC based Automated Hearing Screening kit also has been redesigned in term of user interface and the functionality to submit the data to the centralized database has been added. As part of the project results, the SQL injection test has been performed on web application interface and the web application successfully passed the test by sanitizing user input in the web application. An End User test has been conducted at Audiology & Speech Sciences Clinic, Universiti Kebangsaan Malaysia with 9 participants involved. All participants passed the hearing screening test for the left and right ear except for 1 participant unable to conduct right ear test due to the detected ambient noise level in the test room beyond the permissible level. As the conclusion the objective of this project has been fulfilled and the capabilities of original PC based Automated Hearing Screening kit has been successfully extended based on the results presented in this report. 2014 Thesis http://eprints.utem.edu.my/id/eprint/16214/ http://eprints.utem.edu.my/id/eprint/16214/1/Centralized%20Database%20System%20For%20Automated%20Hearing%20Screening%2024%20Pages.pdf text en public http://library.utem.edu.my:8000/elmu/index.jsp?module=webopac-d&action=fullDisplayRetriever.jsp&szMaterialNo=0000091050 masters Universiti Teknikal Malaysia Melaka Faculty Of Engineering Technology
institution Universiti Teknikal Malaysia Melaka
collection UTeM Repository
language English
topic Q Science (General)
QA76 Computer software
spellingShingle Q Science (General)
QA76 Computer software
Mohd Saad, Hamid
Centralized Database System For Automated Hearing Screening
description Centralized database software enables simultaneous updates from multiple queries containing data from different machines. It enables the data to be stored safely in a centralized location. Based on the related research work on PC based Automated Hearing Screening kit which store the test results in local storage, it may have problem to perform the data collection from different location of test centers. The main objective of this project is to extend the capabilities of the kit into centralized database architecture for easy access of the test results from multiple test centers locations. The proposed methods used in this project involved database structure design through user requirements analysis, defining data type for each entities and modeling the database using entity relationship diagram (ERD). Web application interface has been proposed in this project as a method to extract the test results from the database. The PC based Automated Hearing Screening kit also has been redesigned in term of user interface and the functionality to submit the data to the centralized database has been added. As part of the project results, the SQL injection test has been performed on web application interface and the web application successfully passed the test by sanitizing user input in the web application. An End User test has been conducted at Audiology & Speech Sciences Clinic, Universiti Kebangsaan Malaysia with 9 participants involved. All participants passed the hearing screening test for the left and right ear except for 1 participant unable to conduct right ear test due to the detected ambient noise level in the test room beyond the permissible level. As the conclusion the objective of this project has been fulfilled and the capabilities of original PC based Automated Hearing Screening kit has been successfully extended based on the results presented in this report.
format Thesis
qualification_level Master's degree
author Mohd Saad, Hamid
author_facet Mohd Saad, Hamid
author_sort Mohd Saad, Hamid
title Centralized Database System For Automated Hearing Screening
title_short Centralized Database System For Automated Hearing Screening
title_full Centralized Database System For Automated Hearing Screening
title_fullStr Centralized Database System For Automated Hearing Screening
title_full_unstemmed Centralized Database System For Automated Hearing Screening
title_sort centralized database system for automated hearing screening
granting_institution Universiti Teknikal Malaysia Melaka
granting_department Faculty Of Engineering Technology
publishDate 2014
url http://eprints.utem.edu.my/id/eprint/16214/1/Centralized%20Database%20System%20For%20Automated%20Hearing%20Screening%2024%20Pages.pdf
_version_ 1747833886950293504