Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM

Four grid-connected solar Photovoltaic (PV) systems were installed at Universiti Teknikal Malaysia Melaka (UTeM), namely Thin-Film (TF), Heterojunction with intrinsic thin layer (HIT), Poly crystalline, and Mono crystalline with the total capacity of 24 kWp since October 2013. Hence, it is important...

Full description

Saved in:
Bibliographic Details
Main Author: Mohammed, Hayder Salah
Format: Thesis
Language:English
English
Published: 2017
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/20519/1/Performance%20And%20Degradation%20Evaluation%20Of%20Grid-Connected%20Photovoltaic%20Systems%20At%20UTeM.pdf
http://eprints.utem.edu.my/id/eprint/20519/2/Performance%20and%20degradation%20evaluation%20of%20grid-connected%20photovoltaic%20systems%20at%20UTeM.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utem-ep.20519
record_format uketd_dc
institution Universiti Teknikal Malaysia Melaka
collection UTeM Repository
language English
English
advisor Gan, Chin Kim

topic T Technology (General)
T Technology (General)
spellingShingle T Technology (General)
T Technology (General)
Mohammed, Hayder Salah
Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM
description Four grid-connected solar Photovoltaic (PV) systems were installed at Universiti Teknikal Malaysia Melaka (UTeM), namely Thin-Film (TF), Heterojunction with intrinsic thin layer (HIT), Poly crystalline, and Mono crystalline with the total capacity of 24 kWp since October 2013. Hence, it is important to evaluate the performance and the degradation of UTeM’s PV systems. In this regard, this research aims to evaluate the performance and the degradation of three of the four grid- connected PV systems located at UTeM, Melaka. The analysis presented in this study consists of the data recorded at 5 – minute intervals between January 2014 and December 2015. Meteorological parameters such as solar radiation and ambient temperature, module temperature, and solar generation were obtained from research laboratory of solar PV systems, smart grids, UTeM. The annual performance of the PV systems had been evaluated in terms of capacity factor, availability factor, reference yield, array yield, final yield, performance ratio, system losses, and array capture losses. The annual degradation rates of the PV systems were calculated using Power-Irradiance (P-G) technique. The average performance ratio of Thin-Film PV system for 2014 was 93.6% and 89.2% in 2015, while the average performance ratio of HIT PV system in 2014 was 85% and 82.3% in 2015, and the average performance ratio of Mono crystalline PV system in 2014 was 81.3% and 78.7% in 2015. The average degradation rates for two years of operation of Thin-Film, HIT, and Mono crystalline PV systems were 5.32%, 5.1%, and 3.65%, respectively. This study provides the insight for the system installer and investor in relation to the performance and degradation of various types of PV module technologies installed under Malaysia environment.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Mohammed, Hayder Salah
author_facet Mohammed, Hayder Salah
author_sort Mohammed, Hayder Salah
title Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM
title_short Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM
title_full Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM
title_fullStr Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM
title_full_unstemmed Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM
title_sort performance and degradation evaluation of grid-connected photovoltaic systems at utem
granting_institution Universiti Teknikal Malaysia Melaka
granting_department Faculty Of Electrical Engineering
publishDate 2017
url http://eprints.utem.edu.my/id/eprint/20519/1/Performance%20And%20Degradation%20Evaluation%20Of%20Grid-Connected%20Photovoltaic%20Systems%20At%20UTeM.pdf
http://eprints.utem.edu.my/id/eprint/20519/2/Performance%20and%20degradation%20evaluation%20of%20grid-connected%20photovoltaic%20systems%20at%20UTeM.pdf
_version_ 1747833973295284224
spelling my-utem-ep.205192022-05-17T11:19:51Z Performance and degradation evaluation of grid-connected photovoltaic systems at UTeM 2017 Mohammed, Hayder Salah T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Four grid-connected solar Photovoltaic (PV) systems were installed at Universiti Teknikal Malaysia Melaka (UTeM), namely Thin-Film (TF), Heterojunction with intrinsic thin layer (HIT), Poly crystalline, and Mono crystalline with the total capacity of 24 kWp since October 2013. Hence, it is important to evaluate the performance and the degradation of UTeM’s PV systems. In this regard, this research aims to evaluate the performance and the degradation of three of the four grid- connected PV systems located at UTeM, Melaka. The analysis presented in this study consists of the data recorded at 5 – minute intervals between January 2014 and December 2015. Meteorological parameters such as solar radiation and ambient temperature, module temperature, and solar generation were obtained from research laboratory of solar PV systems, smart grids, UTeM. The annual performance of the PV systems had been evaluated in terms of capacity factor, availability factor, reference yield, array yield, final yield, performance ratio, system losses, and array capture losses. The annual degradation rates of the PV systems were calculated using Power-Irradiance (P-G) technique. The average performance ratio of Thin-Film PV system for 2014 was 93.6% and 89.2% in 2015, while the average performance ratio of HIT PV system in 2014 was 85% and 82.3% in 2015, and the average performance ratio of Mono crystalline PV system in 2014 was 81.3% and 78.7% in 2015. The average degradation rates for two years of operation of Thin-Film, HIT, and Mono crystalline PV systems were 5.32%, 5.1%, and 3.65%, respectively. This study provides the insight for the system installer and investor in relation to the performance and degradation of various types of PV module technologies installed under Malaysia environment. 2017 Thesis http://eprints.utem.edu.my/id/eprint/20519/ http://eprints.utem.edu.my/id/eprint/20519/1/Performance%20And%20Degradation%20Evaluation%20Of%20Grid-Connected%20Photovoltaic%20Systems%20At%20UTeM.pdf text en public http://eprints.utem.edu.my/id/eprint/20519/2/Performance%20and%20degradation%20evaluation%20of%20grid-connected%20photovoltaic%20systems%20at%20UTeM.pdf text en validuser https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=105988 mphil masters Universiti Teknikal Malaysia Melaka Faculty Of Electrical Engineering Gan, Chin Kim 1. A. De Miguel, J. Bilbao, J.R.S. Cazorro, C., 2002. PERFORMANCE ANALYSIS OF AGRID-CONNECTED PV SYSTEM IN A RURAL SITE INTHE NORTHWEST OF SPAIN. 2. Adhikari, S., Kumar, S. & Siripuekpong, P., 2003. Performance of Household Grid-ConnectedPV System in Thailand. Progress in Photovoltaics: Research and Applications, 11(8), pp.557–564. 3. Affandi, R., Gan, C.K. & Ghani, M.R.A., 2014. Performance Comparison for Parabolic DishConcentrating Solar Power in High Level DNI Locations with George Town, Malaysia.Applied Mechanics and Materials, 699, pp.570–576. 4. Akhmad, K. et al., 2014. Outdoor performance of amorphous silicon and polycrystallinesilicon PV modules. Solar Energy Materials and Solar Cells, 46(3), pp.209–218. 5. Alonso García, M.C. & Balenzategui, J.L., 2004. Estimation of photovoltaic module yearlytemperature and performance based on Nominal Operation Cell Temperature calculations. 6. Amin, N., Lung, C.W. & Sopian, K., 2015. A practical field study of various solar cells ontheir performance in Malaysia. Renewable Energy, 34(8), pp.1939–1946. 7. von Appen, J. et al., 2013. Time in the Sun: The Challenge of High PV Penetration in theGerman Electric Grid. IEEE Power & Energy Magazine, (February), pp.55–64.114 8. Attari, K., Elyaakoubi, A. & Asselman, A., 2016. Performance analysis and investigation of agrid-connected photovoltaic installation in Morocco. Energy Reports, 2(December 2015),pp.261–266. 9. Ayompe, L.M. et al., 2011. Measured performance of a 1.72 kW rooftop grid connectedphotovoltaic system in Ireland. Energy Conversion and Management, 52(2), pp.816–825. 10. Bakos, G.C. & Soursos, M., 2006. Technical feasibility and economic viability of a gridconnected PV installation for low cost electricity production. Energy and Buildings, 34(7),pp.753–758. 11. Bernal-Agustín, J.L. & Dufo-López, R., 2006a. Economical and environmental analysis ofgrid connected photovoltaic systems in Spain. Renewable Energy, 31(8), pp.1107–1128. 12. Bernal-Agustín, J.L. & Dufo-López, R., 2006b. Economical and environmental analysis ofgrid connected photovoltaic systems in Spain. Renewable Energy, 31(8), pp.1107–1128. 13. Bharathkumar, M. & Byregowda, H. V, 2014. Performance Evaluation of 5MW GridConnected Solar Photovoltaic Power Plant Established in Karnataka. International Journal ofInnovative Research in Science, Engineering and Technology, 3(6), pp.13862–13868. 14. Billinton, R. & Allan, R.N., 1992. Reliability evaluation of engineering systems- Concepts andtechniques(Book). New York: Plenum Press, 1992.115 15. Blanch, M. & No, D.O., 2009. International Standard 16. .British Standard, 1998. IEC 61724:1998. Photovoltaic system performance monitoring —Guidelines for measurement , data exchange and analysis. , p.20. 17. Burlingame, Q. et al., 2017. Outdoor operation of small-molecule organic photovoltaics.Organic Electronics, 41, pp.274–279. 18. Chen, W., 2012. Renewable Energy Status in Malaysia. , (December), pp.1–41. 19. Cherfa, F. et al., 2015. Performance analysis of the mini-grid connected photovoltaic system atAlgiers. Energy Procedia, 83, pp.226–236. 20. Chicca, M., Wohlgemuth, J. & TamizhMani, G., 2016. Comparative study of 28 and 18 yearsfield aged Siemens-Arco M55 modules in temperate and hot-dry climates. In 2016 IEEE 43rdPhotovoltaic Specialists Conference (PVSC). IEEE, pp. 1686–1691. 21. Chokmaviroj, SomchaiWattanapong Rakwichian, N.K., 2006. Techno-Economic Analysis of500 kW p Photovoltaic Grid Connected System at Mae Hong Son Province. , pp.1–6. 22. Chouder, a & Silvestre, S., 2010. Fault Detection and Automatic Supervision Methodologyfor Pv Systems. 25th European Photovoltaic Solar Energy Conference and Exhibition,(September), pp.4534–4536.116 23. Department, M.M., 2014. Annual Report 2014.pdf. , p.45. 24. Deutsche Gesellschaft fur Sonnenenergie., 2008. Planning and installing photovoltaicsystems : a guide for installers, architects, and engineers, Earthscan. 25. DOE, U.S., 2008. Renewable Energy Data Book. , (July). 26. Duffie, J. a., Beckman, W. a. & Worek, W.M., 2013. Solar Engineering of Thermal Processes,4nd ed.. 27. El-Sebaii, A.A. et al., 2010. Global, direct and diffuse solar radiation on horizontal and tiltedsurfaces in Jeddah, Saudi Arabia. Applied Energy, 87(2), pp.568–576. 28. Elminir, H.K., Benda, V. & Tousek, J., 2001. Effects of solar irradiation conditions on theoutdoor performance of photovoltaic modules. Journal of ELECTRICAL ENGINEERING,52(5–6), pp.125–133. 29. Enerdata, 2014. World Power consumption | Electricity consumption | Enerdata. 30. European Commission, 2005. A Vision for Photovoltaic Technology. 31. European Photovoltaic Industry Association, 2011. Solar photovoltaic electricity empoweringthe world. Solar Generation 6, p.100.117 32. Ghani, A.A.A. et al., 2016. Performance of a 1.2 kWp thin-film free-standing grid-connectedphotovoltaic system at SIRIM berhad. Proceedings - 2015 6th IEEE Control and SystemGraduate Research Colloquium, ICSGRC 2015, pp.76–81. 33. Goel, S. & Sharma, R., 2017. Performance evaluation of stand alone, grid connected andhybrid renewable energy systems for rural application: A comparative review. Renewable andSustainable Energy Reviews, 78, pp.1378–1389. 34. Gong, X. & Kulkarni, M., 2005. Design optimization of a large scale rooftop photovoltaicsystem. Solar Energy, 78(3), pp.362–374. 35. Guide, I., SUNNY BOY 2000HF-US / 2500HF-US / 3000HF-US. 36. Hegedus, S.S. & Luque, A., 2003. Handbook of photovoltaic science and engineering. 37. Huang, H.S. et al., 2011. Performance and Availability Analyses of PV Generation Systems inTaiwan. , 5(1), pp.524–528. 38. Hussin, M.Z. et al., 2010. An evaluation data of solar irradiation and dry bulb temperature atSubang under Malaysian climate. Proceedings - ICSGRC 2010: 2010 IEEE Control andSystem Graduate Research Colloquium, pp.55–60. 39. Hussin, M.Z., Omar, A.M., et al., 2013. Performance of Grid-Connected Photovoltaic Systemin Equatorial Rainforest Fully Humid Climate of Malaysia. International Journal of Applied118Power Engineering (IJAPE), 2(3), pp.105–114. 40. Hussin, M.Z., Shaari, S. & Omar, A.M., 2013. Field performance of grid-connectedphotovoltaic system using amorphous silicon modules. , 8(2). 41. IEA, 2009. Trends in photovoltaic applications. Survey Report of Selected IEA Countriesbetween 1992 and 2008. International Energy Agency. 42. IEA-PVPS, 2014. Trends 2014 in photovoltaic applications. 43. Ineichen, P., 2011. Five satellite products deriving beam and global irradiance validation ondata from 23 ground stations. University of Geneva, (February). 44. Janet L. Sawin, K.M.S., 2017. Renewables 2017: global status report 2017. 45. Jones, A.D. & Underwood, C.P., 2001. A thermal model for photovoltaic systems. SolarEnergy, 70(4), pp.349–359. 46. Jordan, D., Wohlgemuth, J. & Kurtz, S., 2012. Technology and Climate Trends in PV ModuleDegradation 27 th European PV Solar Energy Conference - presentation. Pvsec 27. 47. Jordan, D.C. & Kurtz, S.R., 2013. Photovoltaic degradation rates - An Analytical Review.Progress in Photovoltaics: Research and Applications, 21(1), pp.12–29.119 48. Jumien, N.A., Hussin, M.Z. & Omar, A.M., 2015. performance of a 2.8 kwp MonocrystallineFree-Standing Grid-Connected Photovoltaic System at SIRIM Berhad. , pp.93–97. 49. Kaplani, E. & E., 2012. Detection of Degradation Effects in Field-Aged c-Si Solar Cellsthrough IR Thermography and Digital Image Processing. International Journal ofPhotoenergy, 2012, pp.1–11. 50. Kiefer, K. et al., 2010. A Degradation Analysis of PV Power Plants. Proceedings of 25thEuropean Photovoltaic Solar Energy Conference, (September 2015), pp.5032–5037. 51. Komoni, V., Gebremedhin, A. & Ibrahimi, N., PERFORMANCE EVALUATION OF GRID. ,pp.1–7. 52. Köntges, M. et al., 2014. Review of Failures of Photovoltaic Modules. 53. Kumi, E.N. & Brew-Hammond, A., 2013. Design and Analysis of a 1MW Grid-ConnectedSolar PV System in Ghana. Inovations, (78), pp.301–321. 54. Kymakis, E., Kalykakis, S. & Papazoglou, T.M., 2009a. Performance analysis of a gridconnected photovoltaic park on the island of Crete. Energy Conversion and Management,50(3), pp.433–438. 55. Kymakis, E., Kalykakis, S. & Papazoglou, T.M., 2009b. Performance analysis of a gridconnected photovoltaic park on the island of Crete. Energy Conversion and Management,12050(3), pp.433–438. 56. Larrivee, J., 2013. An analysis of degradation rates of PV power plants at the system level[M.Sc Thesis]. , (April), p.48. 57. Leader, W. et al., 2011. Catalogue of common failures and improper practices on PVinstallations and maintenance. European Photovoltaic Industry Association. 58. Less, S. & To, T., 2014. PROCEDURE FOR THE TESTING AND COMMISSIONING OFGRID- CONNECTED PHOTOVOLTAIC SYSTEMS IN MALAYSIA PART 1 - SYSTEMSLESS THAN OR EQUAL TO 12 kWp SUSTAINABLE ENERGY DEVELOPMENTAUTHORITY ( SEDA ). 59. de Lima, L.C., de Araújo Ferreira, L. & de Lima Morais, F.H.B., 2017. Performance analysisof a grid connected photovoltaic system in northeastern Brazil. Energy for SustainableDevelopment, 37, pp.79–85. 60. Magee, S., 2010. Solar photovoltaic design for residential, commercial and utility systems,The author. 61. Makrides, G. et al., 2013. Energy yield prediction errors and uncertainties of differentphotovoltaic models. Progress in Photovoltaics: Research and Applications, 21(4), pp.500–516.121 62. Makrides, G. et al., 2009. Temperature behaviour of different photovoltaic systems installed inCyprus and Germany. Solar Energy Materials and Solar Cells, 93(6–7), pp.1095–1099 63. Malik, A.Q. & Damit, S.J.B.H., 2007. Outdoor testing of single crystal silicon solar cells. 64. Manukumar, D.M., Ganesha, T. & Math, M.C., 2015. Performance and Evolution of GridConnected To 5MW Solar Photovoltaic Plant in Shivanasamudra. , 3(1), pp.123–128. 65. Marion, B. et al., 2005. Performance parameters for grid-connected PV systems. PhotovoltaicSpecialists Conference, 2005. Conference Record of the Thirty-first IEEE, 31(February),pp.1601–1606. 66. Markvart, T., 2000. Solar electricity, Wiley. 67. Maruyama, E. et al., 2006. Sanyo’s Challenges to the Development of High-efficiency HITSolar Cells and the Expansion of HIT Business. In 2006 IEEE 4th World Conference onPhotovoltaic Energy Conference. IEEE, pp. 1455–1460. 68. Meyer, E.L. & Van Dyk, E.E., 2004. Assessing the reliability and degradation of photovoltaicmodule performance parameters. IEEE Transactions on Reliability, 53(1), pp.83–92. 69. Micheli, D. et al., 2014. Analysis of the outdoor performance and efficiency of two gridconnected photovoltaic systems in northern Italy. Energy Conversion and Management, 80,pp.436–445.122 70. Miller, A. & Lumby, B., 2012. Utility Scale Solar Power Plants. A Guide for developers andinvestors. International Finance Corporation, p.2004. 71. Milosavljević, D.D., Pavlović, T.M. & Piršl, D.S., 2015. Performance analysis of A gridconnected solar PV plant in Niš, republic of Serbia. Renewable and Sustainable EnergyReviews, 44, pp.423–435. 72. Mondol, J.D., Yohanis, Y., et al., 2006. Long term performance analysis of a grid connectedphotovoltaic system in Northern Ireland. Energy Conversion and Management, 47(18),pp.2925–2947. 73. Mondol, J.D., Yohanis, Y.G. & Norton, B., 2006. Optimal sizing of array and inverter forgrid-connected photovoltaic systems. Solar Energy, 80(12), pp.1517–1539. 74. Müllejans, H. et al., 2011. Changes in spectral response with temperature and irradianceintensity. Thin Solid Films, 451, pp.145–151. 75. Muneer, T. (Tariq) et al., 2004. Solar radiation and daylight models : (with software availablefrom companion web site), Elsevier Butterworth Heinemann. 76. Nelson, J., 2003. The physics of solar cells, Imperial College Press. 77. Notton, G., Lazarov, V. & Stoyanov, L., 2010. Optimal sizing of a grid-connected PV systemfor various PV module technologies and inclinations, inverter efficiency characteristics and123locations. 78. Okello, D., Van Dyk, E.E. & Vorster, F.J., 2015. Analysis of measured and simulatedperformance data of a 3.2 kWp grid-connected PV system in Port Elizabeth, South Africa.Energy Conversion and Management, 100, pp.10–15. 79. Osterwald, C.R., 1986. Translation of device performance measurements to referenceconditions. Solar Cells,18,3-4,Pages 269-279, 80401, pp.269–279. 80. Padmavathi, K. & Daniel, S.A., 2013a. Performance analysis of a 3MWp grid connected solarphotovoltaic power plant in India. Energy for Sustainable Development, 17(6), pp.615–625. 81. Padmavathi, K. & Daniel, S.A., 2013b. Performance analysis of a 3MWp grid connected solarphotovoltaic power plant in India. Energy for Sustainable Development, 17(6), pp.615–625. 82. Pearsall, N.M., 2011. PV research and development in Europe - A view from the technologyplatform. Conference Record of the IEEE Photovoltaic Specialists Conference, pp.000200–000205. 83. Pietruszko, S.M. & Gradzki, M., 2003. Performance of a grid connected small PV system inPoland. Applied Energy, 74(1), pp.177–184. 84. Plangklang, B., Thanomsat, N. & Phuksamak, T., 2016. A verification analysis of powerquality and energy yield of a large scale PV rooftop. Energy Reports, 2(November), pp.1–7.124 85. Quintana, M. a. et al., 2011. Commonly observed degradation in field-aged photovoltaicmodules. Conference Record of the Twenty-Ninth IEEE Photovoltaic Specialists Conference,2011., pp.1436–1439. 86. Reich, N.H. et al., 2012. Performance ratio revisited: is PR > 90% realistic? Progress inPhotovoltaics: Research and Applications, 20(6), pp.717–726. 87. Reich, N.H. et al., 2012. System Performance Analysis and Estimation of Degradation RatesBased on 500 Years of Monitoring Data. 38th IEEE Photovoltaic Specialists Conference,pp.1551–1555. 88. Saleh, I.M., Abufares, H.M. & Snousi, H.M., 2013. Three-Year Performance Evaluation ofSingle Junction Amorphous Solar Cells Grid-Connected Power Station in Libya. ConferencePapers in Engineering, 2013, pp.1–5. 89. Sampaio, P.G.V. & González, M.O.A., 2017. Photovoltaic solar energy: Conceptualframework. Renewable and Sustainable Energy Reviews, 74, pp.590–601. 90. SEDA, 2012. SEDA Annual Report 2012. 91. Shaari, S. et al., 2015. The temperature dependence coefficients of amorphous silicon andcrystalline photovoltaic modules using Malaysian field test investigation. American Journal ofApplied Sciences, 6(4), pp.586–593.125 92. Sharma, V. & Chandel, S.S., 2013. Performance analysis of a 190 kWp grid interactive solarphotovoltaic power plant in India. Energy, 55, pp.476–485. 93. Shiva Kumar, B. & Sudhakar, K., 2015. Performance evaluation of 10 MW grid connectedsolar photovoltaic power plant in India. Energy Reports, 1, pp.184–192.Sidrach-de-Cardona, M. & Mora López, L., 1999. Performance analysis of a grid-connectedphotovoltaic system. Energy, 24(2), pp.93–102. 94. Da Silva Freire, F., 2016. Performance and Degradation Analysis of Operating PV Systems. 95. Skoplaki, E. & Palyvos, J.A., 2009. Operating temperature of photovoltaic modules: A surveyof pertinent correlations. Renewable Energy, 34(1), pp.23–29. 96. Sopori, B. et al., 2012. Understanding light-induced degradation of c-Si solar cells.Conference Record of the IEEE Photovoltaic Specialists Conference, (June), pp.1115–1120. 97. Spooner, E.. & Harbidge, G., 2008. Review of international standards for grid connectedphotovoltaic systems. Renewable Energy, 22(1), pp.235–239. 98. Staebler, D.L. & Wronski, C.R., 1980. Optically induced conductivity changes indischarge‐produced hydrogenated amorphous silicon. Journal of Applied Physics, 51(6),pp.3262–3268.126 99. Sukhatme, S.P., 1997. Solar energy : principles of thermal collection and storage, TataMcGraw-Hill. 100. Tam, A., 2013. Feed-in Tariff and Renewable Energy Fund. Parliament of Malaysia, KualaLumpur, p.8. 101. Tenaga National Berhad, 2016. A Brighter Tomorrow Begins with a Better Today: IntegratedAnnual Report 2016. , p.269. 102. Thevenard, D. & Pelland, S., 2011. Estimating the Uncertainty in Long-Term PhotovoltaicYield Predictions. , pp.1–21. 103. Trinuruk, P., Sorapipatana, C. & Chenvidhya, D., 2009. Estimating operating cell temperatureof BIPV modules in Thailand. Renewable Energy, 34(11), pp.2515–2523. 104. Tripathy, S.C. & Saxena, A.K., 1993. Performance evaluation of 20 kWp photovoltaic system.Energy Conversion and Management, 34(8), pp.619–626. 105. Union, E., 2014. Barometer. , (april 2015). 106. W. Paul Menzel, 2001. Chapter 3 - Absorption, Emission, Reflection, and Scattering.Applications With Meteorological Satellites, pp.3–14. 107. Wang, C. & Zeng, K., 2012. A Survey of Nuclear and Solar Energy. Advanced Materials127Research, 535–537, pp.2116–2119. 108. Wenham, S.R. (Stuart R.., 2007. Applied photovoltaics, Earthscan. 109. Zahedi, A., 2006. Solar photovoltaic (PV) energy; latest developments in the buildingintegrated and hybrid PV systems. Renewable Energy, 31(5), pp.711–718. 110. van der Zwaan, B. & Rabl, A., 2007. Prospects for PV: A learning curve analysis. SolarEnergy, 74(1), pp.19–31.