Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System

Summary: Blood glucose monitoring is necessary for diabetes management therapy, where the common method used is an invasive glucose meter that involves finger prick for blood sample which can cause discomfort and skin injury. Painless monitoring of blood glucose would improve patient’s quality of li...

Full description

Saved in:
Bibliographic Details
Main Author: Abd. Salam., Nurul Akmal
Format: Thesis
Language:English
English
Published: 2019
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/24607/1/Development%20And%20Analysis%20Of%20Near-Infrared%20Spectroscopy%20Technique%20For%20Non-Invasive%20Blood%20Glucose%20Monitoring%20System.pdf
http://eprints.utem.edu.my/id/eprint/24607/2/Development%20And%20Analysis%20Of%20Near-Infrared%20Spectroscopy%20Technique%20For%20Non-Invasive%20Blood%20Glucose%20Monitoring%20System.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utem-ep.24607
record_format uketd_dc
institution Universiti Teknikal Malaysia Melaka
collection UTeM Repository
language English
English
advisor Mohd Saad, Wira Hidayat

topic Q Science (General)
QD Chemistry
spellingShingle Q Science (General)
QD Chemistry
Abd. Salam., Nurul Akmal
Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System
description Summary: Blood glucose monitoring is necessary for diabetes management therapy, where the common method used is an invasive glucose meter that involves finger prick for blood sample which can cause discomfort and skin injury. Painless monitoring of blood glucose would improve patient’s quality of life, therefore the development and analysis of near-infrared (NIR) spectroscopy technique for non-invasive blood glucose monitoring system was proposed in this research. An appropriate conditional circuit for photodiode was constructed and 3D sensor casing was designed for output signal stability and noise elimination. The NIR light-emitting diode (LED) with wavelengths of 1050 nm, 1200 nm, 1300 nm, 1450 nm, and 1550 nm and Indium Gallium Arsenide (InGaAs) photodiode were employed in the in-vitro analysis and the Dextrose solution with different concentrations was used as samples. Based on the analysis on the result of the in-vitro experiment, the NIR LED with the wavelength of 1450 nm had the best coefficient of correlation (R2) and it is used in the development of non-invasive blood monitoring device system. The in-vivo experiment utilises humans as subjects. The different area of the human body has a different absorption capability based on tissue composition and thickness. By considering that, three sensing areas, which are the finger, the area between the thumb and index finger, and earlobe, were selected for measurement. By referring to the measurement of the conventional invasive glucose meter, the earlobe area showed the best consistency of voltage output compared to other areas and this area was used to place the sensor prop for blood glucose measurement. A prototype of non-invasive blood glucose with the algorithm to convert voltage reading to glucose reading was developed based on the acquisition of the experiments that have been carried out. This prototype device has an LED indicator to alert the user about the condition of glucose level and Android application to monitor the blood glucose reading. In addition, this system of non-invasive blood glucose had also been developed with the temperature and motion parameters control for stability during the measurement. The Clarkson Error Grid (CEG) analysis was used to determine the accuracy of the measurement and the highest value of R2 indicates a good correlation between the measurement of the proposed device system and conventional invasive glucose meter. Based on the tests performed, the algorithms constructed based on a single subject demonstrate a high reading accuracy The developed device system presented here has been proven to show a good correlation between NIR transmittance and blood glucose reading. However, as such an experimental device is not Food and Drug Administration (FDA) approved, it should only be used for academic or informative purposes, and should not be used for any medical decision-making process.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Abd. Salam., Nurul Akmal
author_facet Abd. Salam., Nurul Akmal
author_sort Abd. Salam., Nurul Akmal
title Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System
title_short Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System
title_full Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System
title_fullStr Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System
title_full_unstemmed Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System
title_sort development and analysis of near-infrared spectroscopy technique for non-invasive blood glucose monitoring system
granting_institution Universiti Teknikal Malaysia Melaka
granting_department Faculty of Electronic and Computer Engineering
publishDate 2019
url http://eprints.utem.edu.my/id/eprint/24607/1/Development%20And%20Analysis%20Of%20Near-Infrared%20Spectroscopy%20Technique%20For%20Non-Invasive%20Blood%20Glucose%20Monitoring%20System.pdf
http://eprints.utem.edu.my/id/eprint/24607/2/Development%20And%20Analysis%20Of%20Near-Infrared%20Spectroscopy%20Technique%20For%20Non-Invasive%20Blood%20Glucose%20Monitoring%20System.pdf
_version_ 1747834076436365312
spelling my-utem-ep.246072021-10-05T11:48:19Z Development And Analysis Of Near-Infrared Spectroscopy Technique For Non-Invasive Blood Glucose Monitoring System 2019 Abd. Salam., Nurul Akmal Q Science (General) QD Chemistry Summary: Blood glucose monitoring is necessary for diabetes management therapy, where the common method used is an invasive glucose meter that involves finger prick for blood sample which can cause discomfort and skin injury. Painless monitoring of blood glucose would improve patient’s quality of life, therefore the development and analysis of near-infrared (NIR) spectroscopy technique for non-invasive blood glucose monitoring system was proposed in this research. An appropriate conditional circuit for photodiode was constructed and 3D sensor casing was designed for output signal stability and noise elimination. The NIR light-emitting diode (LED) with wavelengths of 1050 nm, 1200 nm, 1300 nm, 1450 nm, and 1550 nm and Indium Gallium Arsenide (InGaAs) photodiode were employed in the in-vitro analysis and the Dextrose solution with different concentrations was used as samples. Based on the analysis on the result of the in-vitro experiment, the NIR LED with the wavelength of 1450 nm had the best coefficient of correlation (R2) and it is used in the development of non-invasive blood monitoring device system. The in-vivo experiment utilises humans as subjects. The different area of the human body has a different absorption capability based on tissue composition and thickness. By considering that, three sensing areas, which are the finger, the area between the thumb and index finger, and earlobe, were selected for measurement. By referring to the measurement of the conventional invasive glucose meter, the earlobe area showed the best consistency of voltage output compared to other areas and this area was used to place the sensor prop for blood glucose measurement. A prototype of non-invasive blood glucose with the algorithm to convert voltage reading to glucose reading was developed based on the acquisition of the experiments that have been carried out. This prototype device has an LED indicator to alert the user about the condition of glucose level and Android application to monitor the blood glucose reading. In addition, this system of non-invasive blood glucose had also been developed with the temperature and motion parameters control for stability during the measurement. The Clarkson Error Grid (CEG) analysis was used to determine the accuracy of the measurement and the highest value of R2 indicates a good correlation between the measurement of the proposed device system and conventional invasive glucose meter. Based on the tests performed, the algorithms constructed based on a single subject demonstrate a high reading accuracy The developed device system presented here has been proven to show a good correlation between NIR transmittance and blood glucose reading. However, as such an experimental device is not Food and Drug Administration (FDA) approved, it should only be used for academic or informative purposes, and should not be used for any medical decision-making process. 2019 Thesis http://eprints.utem.edu.my/id/eprint/24607/ http://eprints.utem.edu.my/id/eprint/24607/1/Development%20And%20Analysis%20Of%20Near-Infrared%20Spectroscopy%20Technique%20For%20Non-Invasive%20Blood%20Glucose%20Monitoring%20System.pdf text en public http://eprints.utem.edu.my/id/eprint/24607/2/Development%20And%20Analysis%20Of%20Near-Infrared%20Spectroscopy%20Technique%20For%20Non-Invasive%20Blood%20Glucose%20Monitoring%20System.pdf text en public https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=117083 mphil masters Universiti Teknikal Malaysia Melaka Faculty of Electronic and Computer Engineering Mohd Saad, Wira Hidayat 1. American Diabetes Association, 2014. Diagnosis and classification of diabetes mellitus. Diabetes care, 37(Supplement 1), pp.81-90. 2. Amir, O., Weinstein, D., Zilberman, S., Less, M., Perl-Treves, D., Primack, H., Weinstein, A., Gabis, E., Fikhte, B. and Karasik, A., 2007. Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy.” Journal of Diabetes Science and Technology, 1(4), pp.463–469. 3. Arimoto, H., Tarumi, M. and Yamada, Y., 2003. Instrumental Requirements for Non-Invasive Blood Glucose Measurement Using NIR Spectroscopy. Optical Review, 10(3), pp.161–165. 4. Aziz, N.A.M., Arsad, N., Menon, P.S., Laili, A.R., Laili, M.H. and Halim, A.A.A., 2015. Analysis of difference light sources for non-invasive aqueous glucose detection. 5th IEEE International Conference on Photonics (ICP), pp.150–152. 5. Baba, J.S., Cameron, B.D., Theru, S. and Coté, G.L., 2002. Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye. Journal of Biomedical Optics, 7(3), pp.321–328. 6. Badugu, R., Lakowicz, J.R. and Geddes, C.D., 2003. A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring. Journal of Fluorescence, 13. 7. Bequette, B.W., 2010. Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms. Journal of Diabetes Science and Technology, 4(2), pp.404–418. 8. BERNAMA, 2018. Malaysia mempunyai kadar diabetes tertinggi di Asis. Berita Harian, 25 July. 9. Blevins, T., Bode, B., Garg, S., Grunberger, G., Hirsch, I., Jovanovič, L., Nardacci, E., Orzeck, E., Roberts, V. and Tamborlane, W., 2010. Statement by the American Association of Clinical Endocrinologists Consensus Panel on Continuous Glucose Monitoring. Endocrine Practice, 16(5), pp.730–745. 10. Buda, R.A. and Addi, M.M., 2014. A Portable Non-Invasive Blood Glucose Monitoring Device. IEEE Conference on Biomedical Engineering and Sciencess (IECBES), pp.8–10. 11. C8 MediSensors, 2012. C8 MediSensors Gains CE Mark Approval for the C8 MediSensors Optical Glucose Monitor(TM) System for People with Diabetes [onlinet] Available at: https://www.prnewswire.com/news-releases/c8-medisensors-gains-ce-mark-approval-for-the-c8-medisensors-optical-glucose-monitortm-system-for-people-with-diabetes-175821951.html [Accessed 28 Febuary 2016]. 12. Caldwell, J., 2014. TI Designs – Precision : Verified Design 1 MHz , Single-Supply , Photodiode Amplifier Reference Design. 13. Chee, F. and Fernando, T., 2007. Closed-Loop Control of Blood Glucose. 1st ed. Springer Science & Business Media. 14. Cho, O.K., Kim, Y.O., Mitsumaki, H. and Kuwa, K., 2004. Noninvasive measurement of glucose by metabolic heat conformation method. Clinical Chemistry, 50(10), pp.1894–1898. 15. Chua, C.D., Gonzales, I.M., Manzano, E. and Manzano, M.C., 2014. Design and Fabrication of a Non-Invasive Blood Glucometer Using Paired Photo-Emitter and Detector Near-Infrared LEDs. DLSU Research Congress, pp.1-7. 16. Clark, L.C. and Lyons, C., 1962. Electrode systems for continuous monitoring in cardiovascular surgery. Annals of the New York Academy of Sciences, 102(1), pp.29–45. 17. Clarke, S.F. and Foster, J.R., 2012. A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. British Journal of Biomedical Science, 69(2), pp.83–93. 18. Clarke, W.L., Cox, D., Gonder-Frederick, L.A., Carter, W. and Pohl, S.L., 1987. Evaluating clnical accuracy of systems for self-monitoring of blood glucose. Diabetes Care, 10(5), pp.622–628. 19. Cnoga, 2015. Combo Glucometer [online] Available at.: http://cnogacare.co/portfolio-item/combo-glucometer/ [Accessed on 8.Mac.2016]. 20. Cunningham, D.D. and Stenke, J.A., 2010. A series of monographs on analytical chemistry and its applications: In Vivo Glucose sensing. New Jersey: John Wiley &Sons. Inc. 21. David Mendosa, 2005. History of Blood Glucose Meters. Mendosa.com. [online] Available at: http://www.mendosa.com/history.htm [Accessed on 8 December 2016]. 22. Delpy, D.T., Cope, M., van der Zee, P., Arridge, S.R., Wray, S. and Wyatt, J.S., 1988. Estimation of optical pathlength through tissue from direct time of flight measurement. Physics in Medicine and Biology, 33(12), pp.1433–1442. 23. Dimeski, G., Jones, B.W., Tilley, V., Greenslade, M.N. and Russell, A.W., 2010. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense). Annals of Clinical Biochemistry, 47(Pt 4), pp.358–365. 24. Ferrante do Amaral, C.E. and Wolf, B., 2008. Current development in non-invasive glucose monitoring. Medical Engineering and Physics, 30(5), pp.541–549. 25. Flacke, F., 2004. Pendra®- Non-invasive continuous glucose monitoring based on impedance spectroscopy [online] Available at: http://www.diabetes-symposium.org/index.php?menu=view&id=136#chart=4 [Accessed on 2 Mac 2016]. 26. Freedom Meditech, 2013. ClearPath DS-120 [online] Available at: http://freedom-meditech.com/ [Accessed on 24.January 2016]. 27. GlucoTrack, 2016. GlucoTrack gives you freedom from finger-pricking to help you manage your diabetes. [online] Available at:: http://www.glucotrack.com.au/glucotrack-product-features.html [Accessed 21 October.2016]. 28. Guenter Gauglitz and Vo-Dinh, T., 2006. Handbook of spectroscopy 1st ed. Germany: John Wiley & Sons. 29. Guevara, E. and González, F.J., 2010. Joint optical-electrical technique for noninvasive glucose monitoring. Revista Mexicana de Fisica, 56(5), pp.430–434. 30. Guo, D.X., Shang, Y.Z., Peng, R., Yong, S.S. and Wang, X.A., 2015. Noninvasive Blood Glucose Measurement Based on NIR Spectrums and Double ANN Analysis. Journal of Biosciences and Medicines, pp.42–48. 31. Hamamatsu Photonics, 2015. InGaAs PIN photodiodes. Hamamatsu, Japan. 32. Harper, A. and Anderson, M.R., 2010. Electrochemical glucose sensors-developments using electrostatic assembly and carbon nanotubes for biosensor construction. Sensors, 10(9), pp.8248–8274. 33. Holt, R.I.G., Cockram, C., Flyvbjerg, A. and Goldstein, B.J., 2011. Textbook of Diabetes 4th ed. John Wiley & Sons. 34. Hotmartua, R., Pangestu, P.W., Zakaria, H. and Irawan, Y.S., 2015. Noninvasive Blood Glucose Detection Using Near Infrared Sensor. 5th International Conference on Electrical Engineering and Informatics 2015, pp.687–692. 35. Jeon, K.J., Hwang, I.D., Hahn, S. and Yoon, G., 2006. Comparison between transmittance and reflectance measurements in glucose determination using near infrared spectroscopy. Journal of Biomedical Optics, 11(1), pp.1-7. 36. Kamboh, M.A. and Khan, A., 2013. EDN Networks: Non-invasive blood glucose monitoring using near-infrared spectroscopy. [online] Available at: http://www.edn.com/design/systems-design/4422840/Non-invasive-blood-glucose-monitoring-using-near-infrared-spectroscopy [Accessed on 22 Febuary 2016]. 37. Keenan, D.B., Mastrototaro, J.J., Voskanyan, G. and Steil, G.M., 2009. Delays in minimally invasive continuous glucose monitoring devices: a review of current technology. Journal of Diabetes Science and Technology (Online), 3(5), pp.1207–1214. 38. Khalil, O.S., 1999. Spectroscopic and clinical aspects of noninvasive glucose measurements. Clinical Chemistry, 45(2), pp.165–177. 39. Klonoff, D.C., 2005. Continuous Glucose Monitoring: Roadmap for 21st Century Diabetes Therapy. Diabetes Care, 28(5), pp.1231–1239. 40. Ko, J.B., Cho, O.K., Kim, Y.O. and Yasuda, K., 2004. Body Metabolism Provides a Foundation for Noninvasive Blood Glucose Monitoring. Diabetes Care, 27(5), pp.1211–1212. 41. Krushinitskaya, O., 2012. Osmotic sensor for blood glucose monitoring applications. Vestfold University College. 42. Lai, J.L., Huang, S.Y., Lin, R.S. and Tsai, S.C., 2016. Design a non-invasive near-infrared LED blood glucose sensor. International Conference on Applied System Innovation (ICAS). pp.5–8. 43. Larin, K. V., Eledrisi, M.S., Motamedi, M. and Esenaliev, R.O., 2002. Noninvasive blood glucose monitoring with optical coherence tomography: A pilot study in human subjects. Diabetes Care, 25(12), pp.2263–2267. 44. Liu, R., Deng, B., Chen, W. and Xu, K., 2005. Next step of non-invasive glucose monitor by NIR technique from the well controlled measuring condition and results. Optical and Quantum Electronics, 37(13–15), pp.1305–1317. 45. MacKenzie, H.A., Ashton, H.S., Spiers, S., Shen, Y., Freeborn, S.S., Hannigan, J., Lindberg, J. and Rae, P., 1999. Advances in photoacoustic noninvasive glucose testing. Clinical Chemistry, 45(9), pp.1587–1595. 46. Maruo, K., Tsurugi, M., Chin, J., Ota, T., Arimoto, H., Yamada, Y., Tamura, M., Ishii, M. and Ozaki, Y., 2003. Noninvasive blood glucose assay using a newly developed near-infrared system. Journal of Selected Topics in Quantum Electronics, 9(2), pp.322–330. 47. Mclachlan, K. and Neal, D.O., 2007. The Use of the Continuous Glucose Monitors in Pregnancy. Infusystems USA, 4(4), pp.25–32. 48. Medgadget, 2007. Non-invasive Glucometer from OrSense Approved in Europe [online] Available at: https://www.medgadget.com/2007/06/noninvasive_glucometer_from_orsense_approved_in_europe.html [Accessed on 1 January 2016]. 49. Menon, K.U., Hemachandran, D. and Abhishek, T.K., 2013. A survey on non-invasive blood glucose monitoring using NIR. International Conference on Communication and Signal Processing (ICCSP), pp.1069–1072. 50. NADI, 2011. Burden of Diabetes in Malaysia. Ministry of Health Malaysia. 51. Narkhede, P., Dhalwar, S. and Karthikeyan, B., 2016. NIR based non-invasive blood glucose measurement. Indian Journal of Science and Technology, 9(41), pp.0–7. 52. Newman, J.D. and Turner, A.P.F., 2005. Home blood glucose biosensors: A commercial perspective. Biosensors and Bioelectronics, 20(12), pp.2435–2453. 53. Norman Colthup, 2012. Introduction to Infrared and Raman Spectroscopy 2nd ed., New York: Academic Press Inc. 54. Oliver, N.S., Toumazou, C., Cass, A.E.G. and Johnston, D.G., 2009. Glucose sensors: A review of current and emerging technology. Diabetic Medicine, 26(3), pp.197–210. 55. Osi Optoelectronics, 2009. Photodiode Characteristics. 56. Parab, J.S., Gad, R.S. and Naik, G.M., 2010. Noninvasive glucometer model using partial least square regression technique for human blood matrix. Journal of Applied Physics, 107(10). 57. Paul, B., Manuel, M.P. and Alex, Z.C., 2012. Design and Development of Non invasive Glucose Measurement System. 1st IEEE International Symposium Physics and Technology of Sensors, ISPTS, pp.2–5. 58. Pickup, J.C., Hussain, F., Evans, N.D., Rolinski, O.J. and Birch, D.J.S., 2005. Fluorescence-based glucose sensors. Biosensors and Bioelectronics, 20(12), pp.2555–2565. 59. Poddar, R., Andrews, J.T., Shukla, P. and Sen, P., 2008. Non-Invasive Glucose Monitoring Techniques: A review and current trends, arXiv preprint arXiv:0810.5755. 60. Sato, J., Hirose, T. and Watada, H., 2012. Continuous glucose monitoring system: Is it really accurate , safe and clinically useful?. Journal of Diabetes Investigation, 3(3), pp.225–230. 61. Siesler, H.W., Ozaki, Y., Kawata, S. and Heise, H.M. 2008. Near-Infrared Spectroscopy: Principles, Instruments. John Wiley & Sons. 62. Sison. S., 2017. These Are the Best Colors to Wear According to Your Skin Tone. [online] Available at: https://www.preview.ph/fashion/best-colors-to-wear-according-to-your-skin-tone-a00191-20170524 [Accessed on 7 November 2018]. 63. So, C.F., Choi, K.S., Wong, T.K.S. and Chung, J.W.Y., 2012. Recent advances in noninvasive glucose monitoring. Medical Devices: Evidence and Research, 5(1), pp.45–52. 64. Song, K., Ha, U., Park, S., Bae, J. and Yoo, H.J., 2015. An Impedance and Multi-Wavelength Blood Glucose Estimation. IEEE Journal of Solid-State Circuits, 50(4), pp.1025–1037. 65. Steinhart, J. S., Hart , S. R., 1968. Calibration curves for thermistors, Deep-Sea Research and Oceanographic, Volume 15, Issue 4, pp.497-503. 66. Tenhunen, J., Kopola, H. and Myllylä, R., 1998. Non-Invasive Glucose Measurement based on selective Near-Infrared Absorption: Requirements on Instrumentation and Spectral Range. Measurement, 24(3), pp.173–177. 67. Thorlabs, 2007. Ultra Bright NIR LED Specifications and Documentation. Thorlabs, USA. 68. Troy, T.L. and Thennadil, S.N., 2001. Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm. Journal of Biomedical Optics, 6(2), pp.167-176. 69. Valery V. Tuchin, 2008. Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues, New York: CRC Press. 70. Vashist, S.K., 2013. Continuous Glucose Monitoring Systems: A Review. Diagnostics, 3(4), pp.385–412. 71. Vashist, S.K., 2012. Non-invasive glucose monitoring technology in diabetes management: A review. Analytica Chimica Acta, 750, pp.16–27. 72. Wang, J., 2008. Electrochemical glucose biosensors. Chemical Reviews, 108(2), pp.814–825. 73. Wang, J., 2001. Glucose Biosensors: 40 Years of Advances and Challenges. Electroanalysis, 13(12), pp.983–988. 74. WHO, 1999. Definition, Diagnosis and Classification of Diabetes Mellitus and its Complication. Report of WHO Consultation. World Health Organization, pp.1-59. 75. WHO, 2016. Diabetes country profiles :Malaysia. World Health Organization. 76. WHO, 2016. Global Report on Diabetes. World Health Organization, 978, pp.4–65. 77. Yadav, J., Rani, A., Singh, V. and Murari, B.M., 2015. Comparative Study of Different Measurement Sites Using NIR Based Non-invasive Glucose Measurement System. Proceedings Computer Science, 70, pp.469-475. Jan 2015. Elsevier. 78. Yadav, J., Rani, A., Singh, V. and Murari, B.M., 2014. Near-infrared LED based non-invasive blood glucose sensor. 2014. International Conference on Signal Processing and Integrated Networks (SPIN), pp.591–594. February 2014. IEEE. 79. Yadav, J., Rani, A., Singh, V. and Murari, B.M., 2015. Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy. Biomedical Signal Processing and Control, 18, pp.214–227. 80. Yatim, N.N.M., Zain, Z.M., Jaafar, M.Z., Yusof, Z.M., Laili, A.R., Laili, M.H. and Hisham, M.H, 2014. Noninvasive glucose level determination using diffuse reflectance near infrared spectroscopy and chemometrics analysis based on in vitro sample and human skin. IEEE Conference in Systems, Process and Control (ICSPC), pp. 30-35. IEEE. 81. Yoo, E.H. and Lee, S.Y., 2010. Glucose biosensors: an overview of use in clinical practice. Sensors (Basel, Switzerland), 10(5), pp.4558–4576. 82. Zeng, B., Wang, W., Wang, N., Li, F., Zhai, F. and Hu, L., 2013. Noninvasive Blood Glucose Monitoring System Based on Distributed Multi-Sensors Information Fusion of Multi-Wavelength NIR. Engineering, 5(10), pp. 553-560. 83. Zhang, J., Hodge, W., Hutnick, C. and Wang, X., 2011. Noninvasive diagnostic devices for diabetes through measuring tear glucose. Journal of Diabetes Science and Technology, 5(1), pp.166–172.