Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka

The purpose of this study is to determine the energy usage and energy efficiency in Al-Azim Mosque Melaka which to determine the electrical appliances that have been used by mosque such as fans, lights and air-conditioner. The mosque only use fans and air-conditioners in office. Its electricity bill...

Full description

Saved in:
Bibliographic Details
Main Author: Noordin Saleem, Siti Nur Afifah
Format: Thesis
Language:English
English
Published: 2020
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/25547/1/Energy%20Efficiency%20Study%20To%20Reduce%20Energy%20Usage%20In%20Al-Azim%20Mosque%20Melaka.pdf
http://eprints.utem.edu.my/id/eprint/25547/2/Energy%20Efficiency%20Study%20To%20Reduce%20Energy%20Usage%20In%20Al-Azim%20Mosque%20Melaka.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utem-ep.25547
record_format uketd_dc
institution Universiti Teknikal Malaysia Melaka
collection UTeM Repository
language English
English
advisor Mohd Tahir, Musthafah

topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Noordin Saleem, Siti Nur Afifah
Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka
description The purpose of this study is to determine the energy usage and energy efficiency in Al-Azim Mosque Melaka which to determine the electrical appliances that have been used by mosque such as fans, lights and air-conditioner. The mosque only use fans and air-conditioners in office. Its electricity bills is surprisingly high which costs more than RM14, 000 every month where the electricity bills cause burden to the mosque committee. Basically the income of the mosque come from donation of the worshippers. Thus, the saving of electrical bills will be used for others benefits such as increase the number of activities in the mosque. The aim of this study is to determine total power consumption and energy saving measures in Al-Azim Mosque and to identify the current thermal condition and opportunities for improvement of fans power consumption without compromising comfort level. There are two methods used to determine the energy efficiency in this project by measure and verify the actual power consumption in Al-Azim Mosque in order to search for significant energy usage that can be reduced. Thus, the thermal comfort is to focuses on the suggestion of the usage of fans and office air-conditioners in mosque in order 10 determine the potential energy saving plan. The area for the power consumption has been setup at the electricity main board in Al-Azim Mosque. Then, the thermal comfort methods have select the prayer arca which consists of nine points, point A, B, C, D, E, F, G, H and I. The main physical parameters involved in this project are air temperature (Ta), relative humidity (RH) and air velocity (Va). The measurement is taken by using Three-Phase Electrical Networks Analyser for the power consumption and Thermal Micro Climate for the thermal comfort method. The power consumption research by using Data Viewer Software and the thermal comfort analysis of this study is conducted through Delta Log 10 Software. The power consumption focus on fans ‘which has used about 2% and office air-conditioners usage is about 10% from the total power usage. Hence, the balance from the total percentage is used by lighting. Furthermore, the Coefficient of Performance (COP) for air-conditioners in several rooms has been such as air-conditioners in offices, meeting, Imam and Muezzin rooms. Thus, all the sample rooms have met the criteria which have achieved more than 2.7. Based on the COP results obtained, all the air-conditioners in the sample room are in good conditions and the eficiency of them are in satisfactory range. Next, the thermal comfort also included the analysis Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD) index of measurements. According 10 the obtained results, almost all the air temperature and relative humidity measurement was satisfied the standard and almost 90% air velocity readings were not satisfied the current standard. Furthermore, the questionnaires has been compare with the PMV and PPD results, the results shows the occupant’s thermal sensation has met the results for PMV and PPD.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Noordin Saleem, Siti Nur Afifah
author_facet Noordin Saleem, Siti Nur Afifah
author_sort Noordin Saleem, Siti Nur Afifah
title Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka
title_short Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka
title_full Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka
title_fullStr Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka
title_full_unstemmed Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka
title_sort energy efficiency study to reduce energy usage in al-azim mosque melaka
granting_institution Universiti Teknikal Malaysia Melaka
granting_department Faculty Of Mechanical Engineering
publishDate 2020
url http://eprints.utem.edu.my/id/eprint/25547/1/Energy%20Efficiency%20Study%20To%20Reduce%20Energy%20Usage%20In%20Al-Azim%20Mosque%20Melaka.pdf
http://eprints.utem.edu.my/id/eprint/25547/2/Energy%20Efficiency%20Study%20To%20Reduce%20Energy%20Usage%20In%20Al-Azim%20Mosque%20Melaka.pdf
_version_ 1747834137993019392
spelling my-utem-ep.255472022-01-06T12:31:33Z Energy Efficiency Study To Reduce Energy Usage In Al-Azim Mosque Melaka 2020 Noordin Saleem, Siti Nur Afifah T Technology (General) TJ Mechanical engineering and machinery The purpose of this study is to determine the energy usage and energy efficiency in Al-Azim Mosque Melaka which to determine the electrical appliances that have been used by mosque such as fans, lights and air-conditioner. The mosque only use fans and air-conditioners in office. Its electricity bills is surprisingly high which costs more than RM14, 000 every month where the electricity bills cause burden to the mosque committee. Basically the income of the mosque come from donation of the worshippers. Thus, the saving of electrical bills will be used for others benefits such as increase the number of activities in the mosque. The aim of this study is to determine total power consumption and energy saving measures in Al-Azim Mosque and to identify the current thermal condition and opportunities for improvement of fans power consumption without compromising comfort level. There are two methods used to determine the energy efficiency in this project by measure and verify the actual power consumption in Al-Azim Mosque in order to search for significant energy usage that can be reduced. Thus, the thermal comfort is to focuses on the suggestion of the usage of fans and office air-conditioners in mosque in order 10 determine the potential energy saving plan. The area for the power consumption has been setup at the electricity main board in Al-Azim Mosque. Then, the thermal comfort methods have select the prayer arca which consists of nine points, point A, B, C, D, E, F, G, H and I. The main physical parameters involved in this project are air temperature (Ta), relative humidity (RH) and air velocity (Va). The measurement is taken by using Three-Phase Electrical Networks Analyser for the power consumption and Thermal Micro Climate for the thermal comfort method. The power consumption research by using Data Viewer Software and the thermal comfort analysis of this study is conducted through Delta Log 10 Software. The power consumption focus on fans ‘which has used about 2% and office air-conditioners usage is about 10% from the total power usage. Hence, the balance from the total percentage is used by lighting. Furthermore, the Coefficient of Performance (COP) for air-conditioners in several rooms has been such as air-conditioners in offices, meeting, Imam and Muezzin rooms. Thus, all the sample rooms have met the criteria which have achieved more than 2.7. Based on the COP results obtained, all the air-conditioners in the sample room are in good conditions and the eficiency of them are in satisfactory range. Next, the thermal comfort also included the analysis Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD) index of measurements. According 10 the obtained results, almost all the air temperature and relative humidity measurement was satisfied the standard and almost 90% air velocity readings were not satisfied the current standard. Furthermore, the questionnaires has been compare with the PMV and PPD results, the results shows the occupant’s thermal sensation has met the results for PMV and PPD. 2020 Thesis http://eprints.utem.edu.my/id/eprint/25547/ http://eprints.utem.edu.my/id/eprint/25547/1/Energy%20Efficiency%20Study%20To%20Reduce%20Energy%20Usage%20In%20Al-Azim%20Mosque%20Melaka.pdf text en public http://eprints.utem.edu.my/id/eprint/25547/2/Energy%20Efficiency%20Study%20To%20Reduce%20Energy%20Usage%20In%20Al-Azim%20Mosque%20Melaka.pdf text en validuser https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=117970 mphil masters Universiti Teknikal Malaysia Melaka Faculty Of Mechanical Engineering Mohd Tahir, Musthafah 1. Abdou, A., Al-Homoud, M., Budaiwi,I. and Khaiyat, S. (2015)A Systematic Approach for Energy Audit in Mosques. Architectural Engineering Department, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia. Retrieved from https:/lwww.researchgate.net~publicationl267559943 2. Adel Abdou (2003). Measurement of acoustical characteristicsof mosque in Saudi Arabia.Journal of Acoustical Society ofAmerica. 113(3) 1505- 15 17 3. Al-Homoud MS, Abdou AA, Budaiwi IM. (2009) Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates. Energy and Building; 41(6):607-14 4. Al-Homoud,A.A. Abdou, I.M. Budaiwi, (2009) Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates, Energy and Building. 41 (6) 607-614, http://dx.doi.org/lO.1016/j.enhuild.2008.12.005. 5. ASHRAE Standard 55. (2010). Thermal Environmental Conditionfor Human Occupancy. Atlanta ASHRAE. 6. ASHRAE. (2001). "ASHRAE Handbook Fundamental Volume," American society of Heating, Rej?igerating andAir- Conditioning Engineers., Inc., Atlanta, GA, 2001 7. Bradshaw, V. (2006). Human comfort and health requirements. The Building Environment: Active and Passive Control Systems, 3-38. 8. Budaiwi, (2011) Envelope thermal design for energy savings in mosques in hot-humid climate, J. Building. Perform. Simulation. Energy Conversion and Management. Energy and Building 4 (1) 49-61, http://dx.doi.org/10.1080/ 19401491003746639. 9. Budaiwi, I. & Abdou., A. (2013). HVAC system operational strategies for reduced energy consumption in buildings with intermittent occupancy: The case of mosques. Energy Conversion and Management. Energy and Building. 73: 37-50. 10. Burton, T. Killen, S. Amstrong. J, Melcalfe, N. (2011). What Cause Intraspecific Variation in Resting MetabolismRate and What Are Its Ecological Consequence?Proc.R.Soc.B. Biol.Sci. 278, 3465-3473 11. Cay Arenata (2018). How To Compute Your Air Con's Horsepower Based On Your Room Size. Retrieved from https://www.realliving.com.ph~shopping-services/applianceshow-to-computeyour-air-con-s-horsepower-based-on-your-room-size-a1693-20180419 12. Fanger, P.O. Thermal Comfort Analysis and Application in Environment Engineering. (1970) 13. Gul, M. S.,& Patidar, S. (2015). Understanding the energy consumption and occupancy of amultipurpose academic building. Energy and Buildings, 87, 155-1 65. https://doi.org/l0.1016/j.enbuild.2014.11.027 14. Herring, Horace. (2006). Energy Efficiency- A Critical View. Energy, 31(1), pp. 10-20. International Organizationof Standardization7730, IS0 (1994). IS0 Geneva Revised 1990. 15. Izie, Nur., Abidin, Adiana., Zakaria, Rozana., Noraziemah, N w l . , Pauzi, Mohd., Alqaifi, Nabil., Rina, Shaza., Mazzuanna, Siti. (2017). Energy Efficiency Initiatives in a Campus Building. Procedia - Social and Behavioral Sciences, 56, pp. 1-6. 16. John. and James E. B. (2013). "Principles of Heating, Ventilation and Air Conditioning in Buildings,"lst Ed. New Jersey: John Wiley Inc. pp 137. 17. Jomoah, M., Al-Abdulaziz, A. U., Sreerama,K. (2013). Energy Management in the Building of a University Campus in Saudi Arabia-A Case Study, International Conference on Power Engineering, Energy and Electrical Drives, Istanbul, Turkey. Pp. 659-663. 18. Jones, W.P (2001). Air-Conditioning Engineering Book (Fifth Edition): Butterworth Heinemann. 85-90 19. Kiattipom, W., Somchai, M., Nipon, K. & Wattanapong, R. 2008. The impacts of climatic and economic factors on residential electricity consumption of Bangkok Metropolis. Energy and Buildings 40(8): 1419-25. 20. Lamiaa Abdallah and Tarek El-Shennawy (2017). An Initiative towards Transforming Mosques in Egypt to be Environment-Friendly and Energy Saving. Alexandria higher Institute for Engineering and Technology (AIET) and Alexandria National Refining and Petrochemicals Co. (ANRPC), Alexandria, Egypt. 21. Lo. (2013). Energy Conservation in China's Higher Education Institutions, Energy Policy, 56, pp. 703-710. 22. Malaysian Standard: Energy Efficiency and Use of Renewable Energy for Non-Residential Buildings (Second Revision). (2014). Department ofStandards Malaysia, 1 4 6 . 23. McQuiston, F.C. Parker, J.D. Spitler, J.D. (2005). Heating, Ventilating and Air-Conditioning. Sixth Edition. John Wiley & Sons. Inc. 85-86 24. McQuiston, Parker and Spitler. (2005). "Heating, Ventilating and Air-Conditioning: Analysis and Design," 6th Ed. New Jersey: John Wiley Inc. pp 26-39. Pp 216-226. 25. Mittal, A.K. (2007). Electrical and Mechanic1 Sevices in High Rise Buildings. Design and Estimation Manual. pp 102-104 26. Mokhtar. A. (2015) Comparison of Energy Efficiency Strategiesfor Mosques in the United Arab. Department of Architecture, College of Architecture, Art,and Design, American University of Sharjah, Sharjah, United Arab Emirates. Retrieved from http://dx.doi.org/10.1061/9780784479070.005 27. Muhtazam. (2019). Practical Measurement in Package & Split Unit Air-Conditioning System Training. Universiti Teknikal Malaysia Melaka (UTeM). Mull, T.E (1998). HVAC Principle and Application Manual: Mc Graw-Hill. 9.3-9.4, pp 16.35-16.40 28. Nasir, A. R. M., Musa, A. R., Che-Ani, A. I., Utaberta, N., Abdullah, N. A. G., & Tawil, N. M. (2011). Identification of Indoor Environmental Quality (IEQ) parameter in creating conducive learning environment for architecture studio. Procedia Engineering, 20,354-362. Retrieved from https://doi.org/l0.1016/j.proeng.2011.11.177 29. Noorule Osman. (2013). Air Conditioning System. Retrieved from https://www.slideshare.netlNooruleInieOsmadair-conditioning-system 30. NurIzie., Abidin, Adiana., Zakaria, Rozana., Noraziemah, Nurul., Pauzi, Mohd., Alqaifi, Nabil., Rina, Shaza., Mazzuanna, S. (2017). Energy Efficiency Initiatives in a Campus Building. The Italian Association ofChemica1Engineering, 56, 1-6. https://doi.org/l0.3303/CET1756001 31. Office Coorporate Affairs, (2011). Researcher Found That the Right Temperature for Office Building. Universiti Teknologi Mara (UTM) 32. Peeters, L. De Dear, R. Hensen J, D Haeseleer W. (2009). Thermal Comfort in Residential Building Comfort Values and Scales for Building Energy Simulation.Applied Energy 86(5). 772- 780 33. Pritoni, Marco, Salmon, Kieman, Sanguinetti,Angela., Morejohn, Joshua.,Modera, Mark. (2017). Occupant Thermal Feedback for Improved Efficiency in University Buildings. Energy and Buildings. 144, pp. 241-250. 34. Rahman, A., Khairunnisa., Leman, A. M., Yusof, M Z M., Mubin, M F., Salleh, M N M. (2016). Energy Consumption Analysis Based on Energy Efficiency Approach: A Case of Suburban Area. lO(105I), pp. 1-9.Retrievedfrom http://courses.washington.edu~me333afe/ComfortrtHea1th.pdf 35. Ruparathna, R., Hewage, R., Sadiq, R. (2016). Improving the Energy Efficiency of the Existing Building, Stock: A Critical Review of Commercial and Institutional Buildings, Renewable and Sustainable Energy Reviews, Procedia Engineering. 53, pp. 1032-1045. 36. Saeed SA. (1996)Thermal comfort requirements in hot dry regions with special reference to Riyadh Part 2:for Friday prayer. Int J Ambient Energy;17(1):17-21. Saidur. R, Hasanuzzaman. M, Mahlia. T.M.1, Mohamed. H.A. (2011). Chillers Energy Consumption Saving and Emissions Analysis in an Institutional Buildings. Energy and Building. 36(8). 5233-5238 37. Taufiq, B.N., Masjuki, H. H., Mahlia, T. M. I., Amalina, M. A., Faizul, M. S., Saidur, R. (2007). Energy Analysis of Evaporative Cooling for Reducing Energy Use in a Malaysian Building. Desalination. 209(1-3): 238-243. 38. Thomas Hartman. (2001).All-Variable Speed Centrifugal Chiller Plant. ASHRAE Journal. 43(9). 43-53. 39. Yang Razali, N. Y., Latif, M. T., Dominick, D., Moharnad, N., Sulaiman, F. R., & Srithawirat, T. (2015).Concentration of particulate matter, CO and COz in selected schools in Malaysia. Building and Environment, 87,108-1 16.https://doi.org/ l0.1016/j.buildenv.2015.01.015 40. Yau, Y. H., Chew, B. T., & Saifullah, A. (2011). Thermal Comfort in Lecture Hall in the Tropics, 309-317. 41. Zhaou, H. Liu, Y. Di, Y. Wang, L. (2013). The Effect of Clothing Thermal Resistance and Operative Temperature on Human Skin Temperature. Journal Thermal Biology 38(5). 233-239.