Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system

Thermoacoustic technology has been recognised as the one of green technology as it provides alternatives green working mechanism for engine and refrigeration system. This is due to its simplicity (as there was no moving parts) and the system also use a non-polluting gas. Unfortunately, the fluid dyn...

Full description

Saved in:
Bibliographic Details
Main Author: Johari, Dahlia
Format: Thesis
Language:English
English
Published: 2020
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/25983/1/Investigation%20of%20oscillatory-flow%20behaviour%20across%20internal%20structure%20in%20thermoacoustic%20refrigeration%20system.pdf
http://eprints.utem.edu.my/id/eprint/25983/2/Investigation%20of%20oscillatory-flow%20behaviour%20across%20internal%20structure%20in%20thermoacoustic%20refrigeration%20system.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utem-ep.25983
record_format uketd_dc
spelling my-utem-ep.259832022-09-29T12:27:23Z Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system 2020 Johari, Dahlia T Technology (General) TA Engineering (General). Civil engineering (General) Thermoacoustic technology has been recognised as the one of green technology as it provides alternatives green working mechanism for engine and refrigeration system. This is due to its simplicity (as there was no moving parts) and the system also use a non-polluting gas. Unfortunately, the fluid dynamics of the system is complex and not well understood. The fluid that flows inside the system is flowing in oscillatory conditions following the acoustic wave. In this study, flow distribution inside a standing wave thermoacoustic condition is tested experimentally and numerically. The thermoacoustic system is first modelled using DeltaE software. The model is used as benchmark for setting up of a thermoacoustic rig that is suitable for the investigation of the oscillatory flow behaviour across the internal structures in the thermoacoustic system. The components of the rig include the loudspeaker as the acoustic driver, a resonator made of steel and a structure known as a stack made of aluminium. The stack was a parallel-plate structure where most thermoacoustic effects take place. The test rig was build based on a quarter wavelength standing-wave thermoacoustic design. Therefore, for the purpose of investigating the fluid dynamics of oscillatory flow at different frequencies, the resonator was divided into several segments which was assembled according to flow frequency. Due to the complication of design, the study of flow frequencies was limited to only two flow frequencies, which were 14.2 Hz and 23.6 Hz. For 14.2 Hz flow frequencies, the stack was located at two different locations of 0.11λ and 0.18λ from the pressure antinode while 23.6 Hz flow frequencies, the stack was located at 0.18λ from the pressure antinode. The stack was fabricated with two different lengths of 70 mm and 200 mm. The experimental rig was first tested for resonance frequency and references point followed by the investigation of the change of velocity in each point along the thermoacoustic rig as drive ratio (ratio of pressure at antinode to the mean pressure) changes. The DeltaE software models provide pressure distribution data that are similar to the theoretical data and stack with the length of 200 mm gives a better performance in term of drive ratio (Dr) where an increment of drive ratio percentage of 28% was recorded compared to 25% drive ratio increment for the 70 mm stack. Comparisons were also made for first-order harmonic velocity amplitude, u1, obtained from three different methods; theoretical calculations, DeltaE software, and the experimentally measured values. It is found that the velocity distribution of flow across the 70 mm long stack results in highest Stoke’s Reynolds number which is 271.99 that leads to early starts of turbulence in the flow. The stack’s location of 0.11λ was also found to be the best location based on velocity data of the current flow conditions. Besides that, it is also found that 23.6 Hz flow frequency result in the better drive ratio compared to 14.2 Hz. The findings help to understand possible differences between theoretical and real experimental values so that 2020 Thesis http://eprints.utem.edu.my/id/eprint/25983/ http://eprints.utem.edu.my/id/eprint/25983/1/Investigation%20of%20oscillatory-flow%20behaviour%20across%20internal%20structure%20in%20thermoacoustic%20refrigeration%20system.pdf text en public http://eprints.utem.edu.my/id/eprint/25983/2/Investigation%20of%20oscillatory-flow%20behaviour%20across%20internal%20structure%20in%20thermoacoustic%20refrigeration%20system.pdf text en validuser https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=121063 mphil masters Universiti Teknikal Malaysia Melaka Faculty of Mechanical Engineering Mat Tokit, Ernie
institution Universiti Teknikal Malaysia Melaka
collection UTeM Repository
language English
English
advisor Mat Tokit, Ernie
topic T Technology (General)
T Technology (General)
spellingShingle T Technology (General)
T Technology (General)
Johari, Dahlia
Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system
description Thermoacoustic technology has been recognised as the one of green technology as it provides alternatives green working mechanism for engine and refrigeration system. This is due to its simplicity (as there was no moving parts) and the system also use a non-polluting gas. Unfortunately, the fluid dynamics of the system is complex and not well understood. The fluid that flows inside the system is flowing in oscillatory conditions following the acoustic wave. In this study, flow distribution inside a standing wave thermoacoustic condition is tested experimentally and numerically. The thermoacoustic system is first modelled using DeltaE software. The model is used as benchmark for setting up of a thermoacoustic rig that is suitable for the investigation of the oscillatory flow behaviour across the internal structures in the thermoacoustic system. The components of the rig include the loudspeaker as the acoustic driver, a resonator made of steel and a structure known as a stack made of aluminium. The stack was a parallel-plate structure where most thermoacoustic effects take place. The test rig was build based on a quarter wavelength standing-wave thermoacoustic design. Therefore, for the purpose of investigating the fluid dynamics of oscillatory flow at different frequencies, the resonator was divided into several segments which was assembled according to flow frequency. Due to the complication of design, the study of flow frequencies was limited to only two flow frequencies, which were 14.2 Hz and 23.6 Hz. For 14.2 Hz flow frequencies, the stack was located at two different locations of 0.11λ and 0.18λ from the pressure antinode while 23.6 Hz flow frequencies, the stack was located at 0.18λ from the pressure antinode. The stack was fabricated with two different lengths of 70 mm and 200 mm. The experimental rig was first tested for resonance frequency and references point followed by the investigation of the change of velocity in each point along the thermoacoustic rig as drive ratio (ratio of pressure at antinode to the mean pressure) changes. The DeltaE software models provide pressure distribution data that are similar to the theoretical data and stack with the length of 200 mm gives a better performance in term of drive ratio (Dr) where an increment of drive ratio percentage of 28% was recorded compared to 25% drive ratio increment for the 70 mm stack. Comparisons were also made for first-order harmonic velocity amplitude, u1, obtained from three different methods; theoretical calculations, DeltaE software, and the experimentally measured values. It is found that the velocity distribution of flow across the 70 mm long stack results in highest Stoke’s Reynolds number which is 271.99 that leads to early starts of turbulence in the flow. The stack’s location of 0.11λ was also found to be the best location based on velocity data of the current flow conditions. Besides that, it is also found that 23.6 Hz flow frequency result in the better drive ratio compared to 14.2 Hz. The findings help to understand possible differences between theoretical and real experimental values so that
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Johari, Dahlia
author_facet Johari, Dahlia
author_sort Johari, Dahlia
title Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system
title_short Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system
title_full Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system
title_fullStr Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system
title_full_unstemmed Investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system
title_sort investigation of oscillatory-flow behaviour across internal structure in thermoacoustic refrigeration system
granting_institution Universiti Teknikal Malaysia Melaka
granting_department Faculty of Mechanical Engineering
publishDate 2020
url http://eprints.utem.edu.my/id/eprint/25983/1/Investigation%20of%20oscillatory-flow%20behaviour%20across%20internal%20structure%20in%20thermoacoustic%20refrigeration%20system.pdf
http://eprints.utem.edu.my/id/eprint/25983/2/Investigation%20of%20oscillatory-flow%20behaviour%20across%20internal%20structure%20in%20thermoacoustic%20refrigeration%20system.pdf
_version_ 1747834148231315456