Photoacoustic imaging system for fluid flow visualization and biological tissues characterization

Photoacoustic (PA) imaging is a biomedical imaging modality, which work is based on the photoacoustic effect, to provide illumination of biological tissues with strong optical absorption contrast and high spatial resolution at a short scanning time. The drawbacks of some existing PA fluid imag...

Full description

Saved in:
Bibliographic Details
Main Author: Chua, Hui Ling
Format: Thesis
Language:English
English
English
Published: 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/1006/1/24p%20CHUA%20HUI%20LING.pdf
http://eprints.uthm.edu.my/1006/2/CHUA%20HUI%20LING%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1006/3/CHUA%20HUI%20LING%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.1006
record_format uketd_dc
spelling my-uthm-ep.10062021-09-20T07:11:19Z Photoacoustic imaging system for fluid flow visualization and biological tissues characterization 2020-07 Chua, Hui Ling RC71-78.7 Examination. Diagnosis Including radiography Photoacoustic (PA) imaging is a biomedical imaging modality, which work is based on the photoacoustic effect, to provide illumination of biological tissues with strong optical absorption contrast and high spatial resolution at a short scanning time. The drawbacks of some existing PA fluid imaging systems, which include expensive equipment and their maintenance cost, limited sensitivity in detecting signals from restricted regions. This research describes an in-house developed two-axis PA imaging system for investigation of fluid flow and photoacoustic signatures of biological tissues using a continuous laser beam of output wavelength 633 nm to deliver light to the targeted tissue samples and fluid. The resulting acoustic signal detected by a transducer was used to determine the amplitude of tissues optical absorption via the measured phase value (Ф). This research began with the validation of the functionality of the developed system using biological system comprised of a mock circulatory system overlaid by different parts of poultry namely fat, liver and muscle of different sizes. The validated system was then deployed for use on human subjects, and the considered experiment settings included at rest, under warm water and arterial blood flow occlusion conditions. This work reported a consistent increase in the PA signals of all tissues with both sample size and the fluid flow rate. In addition, fat tissues were found to produce the largest PA signals with mean ±standard deviation (SD) Ф = 1.12 ± 0.11, while muscle produced the least signals with Ф = 0.828 ±0.20, which trend agreed well with the previous literature. It was found from the experiments on human subjects that phase difference (ΔФ) was proportional to the change in the velocity of blood flow within microcirculation of an investigated site. The mean and SD of percent relative phase difference for these volunteers were calculated as 51.68 % ± 24.27 % and -68.57 % ± 14.78 % for warm water and blood flow occlusion condition, respectively. The overall sensitivity of the system is 77. 3%. This work concluded the feasibility of this system for non-invasive assessment and visualization of blood perfusion and biological tissues, which deemed it suitable for implementation in healthcare applications. 2020-07 Thesis http://eprints.uthm.edu.my/1006/ http://eprints.uthm.edu.my/1006/1/24p%20CHUA%20HUI%20LING.pdf text en public http://eprints.uthm.edu.my/1006/2/CHUA%20HUI%20LING%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/1006/3/CHUA%20HUI%20LING%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic RC71-78.7 Examination
Diagnosis Including radiography
spellingShingle RC71-78.7 Examination
Diagnosis Including radiography
Chua, Hui Ling
Photoacoustic imaging system for fluid flow visualization and biological tissues characterization
description Photoacoustic (PA) imaging is a biomedical imaging modality, which work is based on the photoacoustic effect, to provide illumination of biological tissues with strong optical absorption contrast and high spatial resolution at a short scanning time. The drawbacks of some existing PA fluid imaging systems, which include expensive equipment and their maintenance cost, limited sensitivity in detecting signals from restricted regions. This research describes an in-house developed two-axis PA imaging system for investigation of fluid flow and photoacoustic signatures of biological tissues using a continuous laser beam of output wavelength 633 nm to deliver light to the targeted tissue samples and fluid. The resulting acoustic signal detected by a transducer was used to determine the amplitude of tissues optical absorption via the measured phase value (Ф). This research began with the validation of the functionality of the developed system using biological system comprised of a mock circulatory system overlaid by different parts of poultry namely fat, liver and muscle of different sizes. The validated system was then deployed for use on human subjects, and the considered experiment settings included at rest, under warm water and arterial blood flow occlusion conditions. This work reported a consistent increase in the PA signals of all tissues with both sample size and the fluid flow rate. In addition, fat tissues were found to produce the largest PA signals with mean ±standard deviation (SD) Ф = 1.12 ± 0.11, while muscle produced the least signals with Ф = 0.828 ±0.20, which trend agreed well with the previous literature. It was found from the experiments on human subjects that phase difference (ΔФ) was proportional to the change in the velocity of blood flow within microcirculation of an investigated site. The mean and SD of percent relative phase difference for these volunteers were calculated as 51.68 % ± 24.27 % and -68.57 % ± 14.78 % for warm water and blood flow occlusion condition, respectively. The overall sensitivity of the system is 77. 3%. This work concluded the feasibility of this system for non-invasive assessment and visualization of blood perfusion and biological tissues, which deemed it suitable for implementation in healthcare applications.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Chua, Hui Ling
author_facet Chua, Hui Ling
author_sort Chua, Hui Ling
title Photoacoustic imaging system for fluid flow visualization and biological tissues characterization
title_short Photoacoustic imaging system for fluid flow visualization and biological tissues characterization
title_full Photoacoustic imaging system for fluid flow visualization and biological tissues characterization
title_fullStr Photoacoustic imaging system for fluid flow visualization and biological tissues characterization
title_full_unstemmed Photoacoustic imaging system for fluid flow visualization and biological tissues characterization
title_sort photoacoustic imaging system for fluid flow visualization and biological tissues characterization
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Fakulti Kejuruteraan Elektrik dan Elektronik
publishDate 2020
url http://eprints.uthm.edu.my/1006/1/24p%20CHUA%20HUI%20LING.pdf
http://eprints.uthm.edu.my/1006/2/CHUA%20HUI%20LING%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1006/3/CHUA%20HUI%20LING%20WATERMARK.pdf
_version_ 1747830703000649728