Integrated protocol for ground and structures condition assessments using ambient vibration

Safety and serviceability issues on ground or structure normally arise after deterioration or damage appearances. It is worst when there is no regular maintenance program or complete engineering record to carry out the re-evaluation work. Application of ambient vibration (AV) technique is widely use...

Full description

Saved in:
Bibliographic Details
Main Author: Kamarudin, Ahmad Fahmy
Format: Thesis
Language:English
English
English
Published: 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/10800/1/24p%20AHMAD%20FAHMY%20KAMARUDIN.pdf
http://eprints.uthm.edu.my/10800/2/AHMAD%20FAHMY%20KAMARUDIN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/10800/3/AHMAD%20FAHMY%20KAMARUDIN%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.10800
record_format uketd_dc
spelling my-uthm-ep.108002024-05-13T06:55:39Z Integrated protocol for ground and structures condition assessments using ambient vibration 2020-09 Kamarudin, Ahmad Fahmy T Technology (General) Safety and serviceability issues on ground or structure normally arise after deterioration or damage appearances. It is worst when there is no regular maintenance program or complete engineering record to carry out the re-evaluation work. Application of ambient vibration (AV) technique is widely used on ground and structures diagnosis works, but none of an effort to integrate them into a specific protocol. The main goal of this thesis is to develop a robust integrated condition assessment protocol on ground and structure using ambient vibration and the main assessment parameter of origin natural frequency. AV testing was performed using a tri-axial seismometer on ground and reinforced concrete (RC) school buildings, with different geotechnical profiles, building configurations and structural health conditions. Determination of peak natural frequency was computed based on the popular methods of Horizontal to Vertical Spectral Ratio (HVSR) and Fourier Amplitude Spectra (FAS) via GEOPSY software. Started by ground condition assessment protocol, the soil classification, soil thickness, and microzonation maps were determined for local soil condition. Meanwhile, in structural condition assessment protocols, the evaluations were made on rocking effect, soil-structure resonance, structural health monitoring (SHM), and building vulnerability. The analysis was initiated by validation of HVSR method on ground, and verification of FAS method on 4-storey of RC buildings. HVSR has proven to be the reliable method. From repetitive AV measurements had indicated consistent prediction with less than 7.0 % disparity of fundamanetal ground frequency (Fo). FAS method showed 0 % of difference at the first mode of predominant building frequency (fo) prediction and 9.5 % at the fifth fo, with the comparison made to prior research. Microzonation map successfully described the sub-surface profile and the resonance zone. Good health of buildings was obtained in repetitive AV measurement within 1.5 years of maximum gap. In rocking effect protocol, the existence of friction piles was clearly identified. Illustrations of mode shapes at respective fo explained the influence of adjacent building, mass and geometric irregularities. A nomograph was introduced for quick evaluation of several components in the integrated protocols at the end analysis. In conclusion, the developed integrated protocol has demonstrated a novel, reliable and robust condition assessment. It will benefit to any ground and comparable RC building even without complete engineering database. 2020-09 Thesis http://eprints.uthm.edu.my/10800/ http://eprints.uthm.edu.my/10800/1/24p%20AHMAD%20FAHMY%20KAMARUDIN.pdf text en public http://eprints.uthm.edu.my/10800/2/AHMAD%20FAHMY%20KAMARUDIN%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/10800/3/AHMAD%20FAHMY%20KAMARUDIN%20WATERMARK.pdf text en validuser phd doctoral Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Awam dan Alam Bina
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic T Technology (General)
spellingShingle T Technology (General)
Kamarudin, Ahmad Fahmy
Integrated protocol for ground and structures condition assessments using ambient vibration
description Safety and serviceability issues on ground or structure normally arise after deterioration or damage appearances. It is worst when there is no regular maintenance program or complete engineering record to carry out the re-evaluation work. Application of ambient vibration (AV) technique is widely used on ground and structures diagnosis works, but none of an effort to integrate them into a specific protocol. The main goal of this thesis is to develop a robust integrated condition assessment protocol on ground and structure using ambient vibration and the main assessment parameter of origin natural frequency. AV testing was performed using a tri-axial seismometer on ground and reinforced concrete (RC) school buildings, with different geotechnical profiles, building configurations and structural health conditions. Determination of peak natural frequency was computed based on the popular methods of Horizontal to Vertical Spectral Ratio (HVSR) and Fourier Amplitude Spectra (FAS) via GEOPSY software. Started by ground condition assessment protocol, the soil classification, soil thickness, and microzonation maps were determined for local soil condition. Meanwhile, in structural condition assessment protocols, the evaluations were made on rocking effect, soil-structure resonance, structural health monitoring (SHM), and building vulnerability. The analysis was initiated by validation of HVSR method on ground, and verification of FAS method on 4-storey of RC buildings. HVSR has proven to be the reliable method. From repetitive AV measurements had indicated consistent prediction with less than 7.0 % disparity of fundamanetal ground frequency (Fo). FAS method showed 0 % of difference at the first mode of predominant building frequency (fo) prediction and 9.5 % at the fifth fo, with the comparison made to prior research. Microzonation map successfully described the sub-surface profile and the resonance zone. Good health of buildings was obtained in repetitive AV measurement within 1.5 years of maximum gap. In rocking effect protocol, the existence of friction piles was clearly identified. Illustrations of mode shapes at respective fo explained the influence of adjacent building, mass and geometric irregularities. A nomograph was introduced for quick evaluation of several components in the integrated protocols at the end analysis. In conclusion, the developed integrated protocol has demonstrated a novel, reliable and robust condition assessment. It will benefit to any ground and comparable RC building even without complete engineering database.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Kamarudin, Ahmad Fahmy
author_facet Kamarudin, Ahmad Fahmy
author_sort Kamarudin, Ahmad Fahmy
title Integrated protocol for ground and structures condition assessments using ambient vibration
title_short Integrated protocol for ground and structures condition assessments using ambient vibration
title_full Integrated protocol for ground and structures condition assessments using ambient vibration
title_fullStr Integrated protocol for ground and structures condition assessments using ambient vibration
title_full_unstemmed Integrated protocol for ground and structures condition assessments using ambient vibration
title_sort integrated protocol for ground and structures condition assessments using ambient vibration
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Fakulti Kejuruteraan Awam dan Alam Bina
publishDate 2020
url http://eprints.uthm.edu.my/10800/1/24p%20AHMAD%20FAHMY%20KAMARUDIN.pdf
http://eprints.uthm.edu.my/10800/2/AHMAD%20FAHMY%20KAMARUDIN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/10800/3/AHMAD%20FAHMY%20KAMARUDIN%20WATERMARK.pdf
_version_ 1804890117319426048