Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)

This study presents the outcomes of the performance evaluation simulation residual voltage output resulting from lightning arrestors IEEE Recommended model. This simulation uses software Alternative Transient Program - Electromagnetic transients Programmed (ATP-EMTP). This software is very appropria...

Full description

Saved in:
Bibliographic Details
Main Author: Abu Bakar, Hizal
Format: Thesis
Language:English
English
Published: 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/1319/1/24p%20HIZAL%20ABU%20BAKAR.pdf
http://eprints.uthm.edu.my/1319/2/HIZAL%20ABU%20BAKAR%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.1319
record_format uketd_dc
spelling my-uthm-ep.13192021-10-03T06:23:08Z Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP) 2015-01 Abu Bakar, Hizal TK3001-3521 Distribution or transmission of electric power This study presents the outcomes of the performance evaluation simulation residual voltage output resulting from lightning arrestors IEEE Recommended model. This simulation uses software Alternative Transient Program - Electromagnetic transients Programmed (ATP-EMTP). This software is very appropriate in examining the behavior of the system, especially a high voltage system lines. As a result of the comparison can be made in the system of 132kV transmission line between systems that are not supplied with lightning arrestors, system supplied with lightning arrestors with conventional styles and systems supplied with lightning arrestors IEEE Recommended model. The results of the simulation study comparisons can be made by taking into account the peak voltage at sub transient conditions. This situation can determine the 132kV transmission line system can protect the equipment properly. Selection lightning 10kA with the 8μs fast front surge and trailing the current time is 20μs is appropriate in the circumstances lightning eruption in Malaysia. In this research, 132kV transmission line parameter tower need to be enclosed by the actual value of the output to the accurate or almost accurate in determining the ability of a lightning arrester in the system. 2015-01 Thesis http://eprints.uthm.edu.my/1319/ http://eprints.uthm.edu.my/1319/1/24p%20HIZAL%20ABU%20BAKAR.pdf text en public http://eprints.uthm.edu.my/1319/2/HIZAL%20ABU%20BAKAR%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Faculty of Electrical & Electronic Engineering
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
topic TK3001-3521 Distribution or transmission of electric power
spellingShingle TK3001-3521 Distribution or transmission of electric power
Abu Bakar, Hizal
Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)
description This study presents the outcomes of the performance evaluation simulation residual voltage output resulting from lightning arrestors IEEE Recommended model. This simulation uses software Alternative Transient Program - Electromagnetic transients Programmed (ATP-EMTP). This software is very appropriate in examining the behavior of the system, especially a high voltage system lines. As a result of the comparison can be made in the system of 132kV transmission line between systems that are not supplied with lightning arrestors, system supplied with lightning arrestors with conventional styles and systems supplied with lightning arrestors IEEE Recommended model. The results of the simulation study comparisons can be made by taking into account the peak voltage at sub transient conditions. This situation can determine the 132kV transmission line system can protect the equipment properly. Selection lightning 10kA with the 8μs fast front surge and trailing the current time is 20μs is appropriate in the circumstances lightning eruption in Malaysia. In this research, 132kV transmission line parameter tower need to be enclosed by the actual value of the output to the accurate or almost accurate in determining the ability of a lightning arrester in the system.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Abu Bakar, Hizal
author_facet Abu Bakar, Hizal
author_sort Abu Bakar, Hizal
title Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)
title_short Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)
title_full Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)
title_fullStr Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)
title_full_unstemmed Fast transient simulation of IEEE recommended surge arrester model on a transmission line using alternative transient program (ATP)
title_sort fast transient simulation of ieee recommended surge arrester model on a transmission line using alternative transient program (atp)
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Faculty of Electrical & Electronic Engineering
publishDate 2015
url http://eprints.uthm.edu.my/1319/1/24p%20HIZAL%20ABU%20BAKAR.pdf
http://eprints.uthm.edu.my/1319/2/HIZAL%20ABU%20BAKAR%20WATERMARK.pdf
_version_ 1747830769246535680