Modelling of pad support for foot osteoarthritis

Osteoarthritis (OA) is a disease that affects joints or ankles of human body that will cause the patients of this disease feels pain, swelling and stiffness in the joint. Human who was affected by the foot osteoarthritis (OA) disease always have problem in doing daily activities due to the pain at t...

Full description

Saved in:
Bibliographic Details
Main Author: Rosli, Mohd Eley
Format: Thesis
Language:English
English
English
Published: 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/1364/2/MOHD%20ELEY%20ROSLI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1364/1/24p%20MOHD%20ELEY%20ROSLI.pdf
http://eprints.uthm.edu.my/1364/3/MOHD%20ELEY%20ROSLI%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.1364
record_format uketd_dc
spelling my-uthm-ep.13642021-10-03T06:35:36Z Modelling of pad support for foot osteoarthritis 2015-01 Rosli, Mohd Eley RD Surgery Osteoarthritis (OA) is a disease that affects joints or ankles of human body that will cause the patients of this disease feels pain, swelling and stiffness in the joint. Human who was affected by the foot osteoarthritis (OA) disease always have problem in doing daily activities due to the pain at their foot. OA patients will always feel pain and stiffness in the inflammation joint. They also feel swelling in or near that joint. These symptoms will always make them difficult in walking and bending their affected joints or ankles when doing daily activities. In relieve the pain that having by the patient, a research of developing the pad support had been done. Development of pad support for osteoarthritis patient which is focused on big toe osteoarthritis become a subject of study and ABAQUS 6.13 software is selected as preferred software to design the geometry of pad support and analysed it using finite element analysis. The CAD model of the pad support then imposed to pressure load to study the effect of this pressure load upon proposed geometries and materials. Three types of geometry models and three types of materials used have been studied for this project. Then the results of the analysis had been discussed by observing to three parameters which is stress, pressure and reaction force. Lastly, the development of big toe osteoarthritis pad support had been studied. 2015-01 Thesis http://eprints.uthm.edu.my/1364/ http://eprints.uthm.edu.my/1364/2/MOHD%20ELEY%20ROSLI%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/1364/1/24p%20MOHD%20ELEY%20ROSLI.pdf text en public http://eprints.uthm.edu.my/1364/3/MOHD%20ELEY%20ROSLI%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Faculty of Mechanical and Manufacturing Engineering
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic RD Surgery
spellingShingle RD Surgery
Rosli, Mohd Eley
Modelling of pad support for foot osteoarthritis
description Osteoarthritis (OA) is a disease that affects joints or ankles of human body that will cause the patients of this disease feels pain, swelling and stiffness in the joint. Human who was affected by the foot osteoarthritis (OA) disease always have problem in doing daily activities due to the pain at their foot. OA patients will always feel pain and stiffness in the inflammation joint. They also feel swelling in or near that joint. These symptoms will always make them difficult in walking and bending their affected joints or ankles when doing daily activities. In relieve the pain that having by the patient, a research of developing the pad support had been done. Development of pad support for osteoarthritis patient which is focused on big toe osteoarthritis become a subject of study and ABAQUS 6.13 software is selected as preferred software to design the geometry of pad support and analysed it using finite element analysis. The CAD model of the pad support then imposed to pressure load to study the effect of this pressure load upon proposed geometries and materials. Three types of geometry models and three types of materials used have been studied for this project. Then the results of the analysis had been discussed by observing to three parameters which is stress, pressure and reaction force. Lastly, the development of big toe osteoarthritis pad support had been studied.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Rosli, Mohd Eley
author_facet Rosli, Mohd Eley
author_sort Rosli, Mohd Eley
title Modelling of pad support for foot osteoarthritis
title_short Modelling of pad support for foot osteoarthritis
title_full Modelling of pad support for foot osteoarthritis
title_fullStr Modelling of pad support for foot osteoarthritis
title_full_unstemmed Modelling of pad support for foot osteoarthritis
title_sort modelling of pad support for foot osteoarthritis
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Faculty of Mechanical and Manufacturing Engineering
publishDate 2015
url http://eprints.uthm.edu.my/1364/2/MOHD%20ELEY%20ROSLI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1364/1/24p%20MOHD%20ELEY%20ROSLI.pdf
http://eprints.uthm.edu.my/1364/3/MOHD%20ELEY%20ROSLI%20WATERMARK.pdf
_version_ 1747830775362879488