Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer

Electromagnetic coils form the basis of magnetic particle imaging (MPI) scanners. Previous scanner designs employ Helmholtz coil arrangement which has low sensitivity and high cost of fabrication. Furthermore, the scanners have long signal acquisition time and high memory requirement. This research...

Full description

Saved in:
Bibliographic Details
Main Author: Abubakar Sadiq, Abdulkadir
Format: Thesis
Language:English
English
English
Published: 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/144/1/24p%20ABDULKADIR%20ABUBAKAR%20SADIQ.pdf
http://eprints.uthm.edu.my/144/2/ABDULKADIR%20ABUBAKAR%20SADIQ%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/144/3/ABDULKADIR%20ABUBAKAR%20SADIQ%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.144
record_format uketd_dc
spelling my-uthm-ep.1442021-07-06T06:34:47Z Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer 2018-09 Abubakar Sadiq, Abdulkadir QC Physics Electromagnetic coils form the basis of magnetic particle imaging (MPI) scanners. Previous scanner designs employ Helmholtz coil arrangement which has low sensitivity and high cost of fabrication. Furthermore, the scanners have long signal acquisition time and high memory requirement. This research focuses on developing a simple, low-cost and low memory demanding one-dimensional MPI scanner capable of imaging the position and concentration of magnetic nanoparticles (MNPs), using electromagnetic coils in the form of solenoids. The scanner produces an oscillatory magnetic field to excite the MNPs and a static magnetic field to confine the region of interest. The MNPs reacted with a nonlinear magnetisation response, inducing a voltage signal that was measured with an appropriate gradiometer pickup coil. In Fourier space, the received voltage signal consists of the fundamental excitation frequency and harmonics. This research utilises the second harmonic response of the MNPs to determine their position and concentration. Analogue Bandpass and Bandstop filters were designed for signal excitation and reception. Resovist and Perimag MNPs in liquid and immobilised form were used as tracer materials, which were moved to different spatial positions through the field of view (FOV), to record the induced voltages. The magnitude response of the Bandpass filter with 22.8 kHz fundamental frequency shows a flat amplitude in the passband with a smooth roll-off rate of ±80 dB/pole, while the Bandstop filter efficiently attenuates the fundamental frequency and passed the 45.6 kHz second harmonic frequency. Results of the excitation coil design revealed that a magnetic field within the range of 0.8 mT to 4.4 mT was obtained, while a voltage in microvolts range was induced in the gradiometer pickup coil. The contour maps derived from imaging one and two samples of the MNPs in the XY-plane revealed their position and shape. Additionally, the average threshold of the peak signal amplitude was obtained as 10.63 μV that would indicate the presence of MNPs concentration sufficient for cancer detection. The developed single-sided MPI scanner has a spatial resolution of less than 1 mm, a pixel resolution of 51.5 megapixels and 42.1 ms image acquisition time. Thus, the outcome of this research showed that the developed single-side MPI scanner has a potential in the detection of MNPs, which could help in sentinel lymph node biopsy for breast cancer diagnosis. 2018-09 Thesis http://eprints.uthm.edu.my/144/ http://eprints.uthm.edu.my/144/1/24p%20ABDULKADIR%20ABUBAKAR%20SADIQ.pdf text en public http://eprints.uthm.edu.my/144/2/ABDULKADIR%20ABUBAKAR%20SADIQ%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/144/3/ABDULKADIR%20ABUBAKAR%20SADIQ%20WATERMARK.pdf text en validuser phd doctoral Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic QC Physics
spellingShingle QC Physics
Abubakar Sadiq, Abdulkadir
Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer
description Electromagnetic coils form the basis of magnetic particle imaging (MPI) scanners. Previous scanner designs employ Helmholtz coil arrangement which has low sensitivity and high cost of fabrication. Furthermore, the scanners have long signal acquisition time and high memory requirement. This research focuses on developing a simple, low-cost and low memory demanding one-dimensional MPI scanner capable of imaging the position and concentration of magnetic nanoparticles (MNPs), using electromagnetic coils in the form of solenoids. The scanner produces an oscillatory magnetic field to excite the MNPs and a static magnetic field to confine the region of interest. The MNPs reacted with a nonlinear magnetisation response, inducing a voltage signal that was measured with an appropriate gradiometer pickup coil. In Fourier space, the received voltage signal consists of the fundamental excitation frequency and harmonics. This research utilises the second harmonic response of the MNPs to determine their position and concentration. Analogue Bandpass and Bandstop filters were designed for signal excitation and reception. Resovist and Perimag MNPs in liquid and immobilised form were used as tracer materials, which were moved to different spatial positions through the field of view (FOV), to record the induced voltages. The magnitude response of the Bandpass filter with 22.8 kHz fundamental frequency shows a flat amplitude in the passband with a smooth roll-off rate of ±80 dB/pole, while the Bandstop filter efficiently attenuates the fundamental frequency and passed the 45.6 kHz second harmonic frequency. Results of the excitation coil design revealed that a magnetic field within the range of 0.8 mT to 4.4 mT was obtained, while a voltage in microvolts range was induced in the gradiometer pickup coil. The contour maps derived from imaging one and two samples of the MNPs in the XY-plane revealed their position and shape. Additionally, the average threshold of the peak signal amplitude was obtained as 10.63 μV that would indicate the presence of MNPs concentration sufficient for cancer detection. The developed single-sided MPI scanner has a spatial resolution of less than 1 mm, a pixel resolution of 51.5 megapixels and 42.1 ms image acquisition time. Thus, the outcome of this research showed that the developed single-side MPI scanner has a potential in the detection of MNPs, which could help in sentinel lymph node biopsy for breast cancer diagnosis.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Abubakar Sadiq, Abdulkadir
author_facet Abubakar Sadiq, Abdulkadir
author_sort Abubakar Sadiq, Abdulkadir
title Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer
title_short Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer
title_full Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer
title_fullStr Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer
title_full_unstemmed Single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer
title_sort single-sided magnetic nanoparticles imaging scanner for early detection of breast cancer
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Fakulti Kejuruteraan Elektrik dan Elektronik
publishDate 2018
url http://eprints.uthm.edu.my/144/1/24p%20ABDULKADIR%20ABUBAKAR%20SADIQ.pdf
http://eprints.uthm.edu.my/144/2/ABDULKADIR%20ABUBAKAR%20SADIQ%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/144/3/ABDULKADIR%20ABUBAKAR%20SADIQ%20WATERMARK.pdf
_version_ 1747830539593711616