Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment

Indoor Air Quality (IAQ) is a part of Building Environment. Nowadays, the construction of new building took place over the world. Upon new building occupancy, a lot of indoors material was used without IAQ concern. This study has been conducted in a new constructed building of the National Instit...

Full description

Saved in:
Bibliographic Details
Main Author: Noraini, Nor Mohd Razif
Format: Thesis
Language:English
English
English
Published: 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/1607/1/24p%20NOR%20MOHD%20RAZIF%20NORAINI.pdf
http://eprints.uthm.edu.my/1607/2/NOR%20MOHD%20RAZIF%20NORAINI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1607/3/NOR%20MOHD%20RAZIF%20NORAINI%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.1607
record_format uketd_dc
spelling my-uthm-ep.16072021-10-03T08:09:31Z Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment 2015-05 Noraini, Nor Mohd Razif TD878-894 Special types of environment, Including soil pollution, air pollution, noise pollution Indoor Air Quality (IAQ) is a part of Building Environment. Nowadays, the construction of new building took place over the world. Upon new building occupancy, a lot of indoors material was used without IAQ concern. This study has been conducted in a new constructed building of the National Institute of Occupational Safety and Health (NIOSH) Malaysia. The goal of the study is to monitor on the level of IAQ parameters including chemical and physical parameters within four consequent stages which are before furniture install, after furniture install and during one and three month occupancy. The indoor parameters have been measured consist of nine parameters including of Carbon Dioxide (CO2), Carbon Monoxide (CO), Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM10), Ozone, Relative Humidity (RH), Temperature and Air Movement. The interaction between Malaysian and international standard was referred and utilized in collecting the data and analyzing of the findings. There was a significant correlation between the high values of RH, Formaldehyde and PM10 where (r 0.324, p <0.05), (r 0.344, p <0.05) and (r 0.319, p<0.05) with extension of phases of new building occupancy respectively. This study established significant different on Formaldehyde and Particulate Matter (PM10) concentration level as go along with the building occupancy. These finding indicated that furniture and fittings, indoor materials and human population has a potential sources of indoor air contaminants. It is recommended that the management should be aware to their indoor air status to protect the occupant from the risk of unwanted exposure especially during the early stage of building occupancy. Finally this research has fully supported the Malaysian need to formulate of future guideline on IAQ commissioning and maintenance of new building occupancy. 2015-05 Thesis http://eprints.uthm.edu.my/1607/ http://eprints.uthm.edu.my/1607/1/24p%20NOR%20MOHD%20RAZIF%20NORAINI.pdf text en public http://eprints.uthm.edu.my/1607/2/NOR%20MOHD%20RAZIF%20NORAINI%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/1607/3/NOR%20MOHD%20RAZIF%20NORAINI%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Malaysia Fakulti Kejuruteraan Mekanikal dan Pembuatan
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TD878-894 Special types of environment
Including soil pollution
air pollution
noise pollution
spellingShingle TD878-894 Special types of environment
Including soil pollution
air pollution
noise pollution
Noraini, Nor Mohd Razif
Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment
description Indoor Air Quality (IAQ) is a part of Building Environment. Nowadays, the construction of new building took place over the world. Upon new building occupancy, a lot of indoors material was used without IAQ concern. This study has been conducted in a new constructed building of the National Institute of Occupational Safety and Health (NIOSH) Malaysia. The goal of the study is to monitor on the level of IAQ parameters including chemical and physical parameters within four consequent stages which are before furniture install, after furniture install and during one and three month occupancy. The indoor parameters have been measured consist of nine parameters including of Carbon Dioxide (CO2), Carbon Monoxide (CO), Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM10), Ozone, Relative Humidity (RH), Temperature and Air Movement. The interaction between Malaysian and international standard was referred and utilized in collecting the data and analyzing of the findings. There was a significant correlation between the high values of RH, Formaldehyde and PM10 where (r 0.324, p <0.05), (r 0.344, p <0.05) and (r 0.319, p<0.05) with extension of phases of new building occupancy respectively. This study established significant different on Formaldehyde and Particulate Matter (PM10) concentration level as go along with the building occupancy. These finding indicated that furniture and fittings, indoor materials and human population has a potential sources of indoor air contaminants. It is recommended that the management should be aware to their indoor air status to protect the occupant from the risk of unwanted exposure especially during the early stage of building occupancy. Finally this research has fully supported the Malaysian need to formulate of future guideline on IAQ commissioning and maintenance of new building occupancy.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Noraini, Nor Mohd Razif
author_facet Noraini, Nor Mohd Razif
author_sort Noraini, Nor Mohd Razif
title Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment
title_short Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment
title_full Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment
title_fullStr Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment
title_full_unstemmed Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment
title_sort comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment
granting_institution Universiti Tun Hussein Malaysia
granting_department Fakulti Kejuruteraan Mekanikal dan Pembuatan
publishDate 2015
url http://eprints.uthm.edu.my/1607/1/24p%20NOR%20MOHD%20RAZIF%20NORAINI.pdf
http://eprints.uthm.edu.my/1607/2/NOR%20MOHD%20RAZIF%20NORAINI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1607/3/NOR%20MOHD%20RAZIF%20NORAINI%20WATERMARK.pdf
_version_ 1747830827993006080