Water reticulation model for Taman Maju, Parit Raja
A numerical model is developed to quantify energy head losses occurred in the water distribution network of Taman Maju, Parit Raja, Johor. A numerical computation has the advantage over a manual computation when analyzing a complex distribution network. The programming language used in this st...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English English |
Published: |
2011
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/2858/1/24p%20OTMAN%20MOHAMED%20O.%20ELOJALI.pdf http://eprints.uthm.edu.my/2858/2/OTMAN%20MOHAMED%20O.%20ELOJALI%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/2858/3/OTMAN%20MOHAMED%20O.%20ELOJALI%20WATERMARK.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uthm-ep.2858 |
---|---|
record_format |
uketd_dc |
spelling |
my-uthm-ep.28582021-11-02T03:24:57Z Water reticulation model for Taman Maju, Parit Raja 2011-05 O. Elojali, Otman Mohamed TD Environmental technology. Sanitary engineering TD481-493 Water distribution systems A numerical model is developed to quantify energy head losses occurred in the water distribution network of Taman Maju, Parit Raja, Johor. A numerical computation has the advantage over a manual computation when analyzing a complex distribution network. The programming language used in this study is the Microsoft Visual Basic 6.0. Hardy-Cross method is selected to calculate the total energy head loss incurred in the looped water distribution network of Taman Maju. The type of pipe used in the water distribution network of Taman Maju is the unplasticised polyvinyl chloride (uPVC) type with the roughness coefficient k = 0.0015 mm. Since Taman Maju consists of terrace houses, the water demand is 1360 litres/unit/day. Three loop networks are considered, namely loop A, B and C for Taman Maju reticulation system. The final flow rate in each pipe has been obtained. This model is helpful in reducing the period of time to calculate the flow rate which is found to be within the piping system design requirement. If comparison is made between the manual calculation, it will definitely shows some difference. The final result will be different because the decimal places fixed are different in manual and model 2011-05 Thesis http://eprints.uthm.edu.my/2858/ http://eprints.uthm.edu.my/2858/1/24p%20OTMAN%20MOHAMED%20O.%20ELOJALI.pdf text en public http://eprints.uthm.edu.my/2858/2/OTMAN%20MOHAMED%20O.%20ELOJALI%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/2858/3/OTMAN%20MOHAMED%20O.%20ELOJALI%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Awam dan Alam Bina |
institution |
Universiti Tun Hussein Onn Malaysia |
collection |
UTHM Institutional Repository |
language |
English English English |
topic |
TD Environmental technology Sanitary engineering TD481-493 Water distribution systems |
spellingShingle |
TD Environmental technology Sanitary engineering TD481-493 Water distribution systems O. Elojali, Otman Mohamed Water reticulation model for Taman Maju, Parit Raja |
description |
A numerical model is developed to quantify energy head losses occurred in the water
distribution network of Taman Maju, Parit Raja, Johor. A numerical computation has
the advantage over a manual computation when analyzing a complex distribution
network. The programming language used in this study is the Microsoft Visual Basic
6.0. Hardy-Cross method is selected to calculate the total energy head loss incurred
in the looped water distribution network of Taman Maju. The type of pipe used in the
water distribution network of Taman Maju is the unplasticised polyvinyl chloride
(uPVC) type with the roughness coefficient k = 0.0015 mm. Since Taman Maju
consists of terrace houses, the water demand is 1360 litres/unit/day. Three loop
networks are considered, namely loop A, B and C for Taman Maju reticulation
system. The final flow rate in each pipe has been obtained. This model is helpful in
reducing the period of time to calculate the flow rate which is found to be within the
piping system design requirement. If comparison is made between the manual
calculation, it will definitely shows some difference. The final result will be different
because the decimal places fixed are different in manual and model |
format |
Thesis |
qualification_name |
Master of Philosophy (M.Phil.) |
qualification_level |
Master's degree |
author |
O. Elojali, Otman Mohamed |
author_facet |
O. Elojali, Otman Mohamed |
author_sort |
O. Elojali, Otman Mohamed |
title |
Water reticulation model for Taman Maju, Parit Raja |
title_short |
Water reticulation model for Taman Maju, Parit Raja |
title_full |
Water reticulation model for Taman Maju, Parit Raja |
title_fullStr |
Water reticulation model for Taman Maju, Parit Raja |
title_full_unstemmed |
Water reticulation model for Taman Maju, Parit Raja |
title_sort |
water reticulation model for taman maju, parit raja |
granting_institution |
Universiti Tun Hussein Onn Malaysia |
granting_department |
Fakulti Kejuruteraan Awam dan Alam Bina |
publishDate |
2011 |
url |
http://eprints.uthm.edu.my/2858/1/24p%20OTMAN%20MOHAMED%20O.%20ELOJALI.pdf http://eprints.uthm.edu.my/2858/2/OTMAN%20MOHAMED%20O.%20ELOJALI%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/2858/3/OTMAN%20MOHAMED%20O.%20ELOJALI%20WATERMARK.pdf |
_version_ |
1747830994390482944 |