Evaluation of heat exchanger on thermoacoustic performance

Thermoacoustic devices have the potential to provide electricity from waste heat to more efficiently use energy resources and to provide new access to electricity for millions of persons around the world. There are many factor influence thermoacoustic performance and this study was focused on a new...

Full description

Saved in:
Bibliographic Details
Main Author: Yahaya, Mohd Zubir
Format: Thesis
Language:English
English
English
Published: 2013
Subjects:
Online Access:http://eprints.uthm.edu.my/6702/1/24p%20MOHD%20ZUBIR%20YAHAYA.pdf
http://eprints.uthm.edu.my/6702/2/MOHD%20ZUBIR%20YAHAYA%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/6702/3/MOHD%20ZUBIR%20YAHAYA%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.6702
record_format uketd_dc
spelling my-uthm-ep.67022022-03-14T02:12:07Z Evaluation of heat exchanger on thermoacoustic performance 2013-06 Yahaya, Mohd Zubir TJ Mechanical engineering and machinery TJ255-265 Heat engines Thermoacoustic devices have the potential to provide electricity from waste heat to more efficiently use energy resources and to provide new access to electricity for millions of persons around the world. There are many factor influence thermoacoustic performance and this study was focused on a new design of thermoacoustic’s heat exchanger and evaluation of its performance in terms of thermal analysis. Through several ideas from researchers in this field, this study was produced with three designs of heat exchangers which are wiretype, fingertype and startype that specifically one of them will be used in experimental test later. Theoretical analysis shows that heat conduction through a full body of heat exchanger are 67.36 W and 39.81 W for both copper and aluminium. Analyzing heat conduction of a fin separately by types of heat exchangers, the highest value of heat conduction through a fin was recorded by startype heat exchanger’s fin using copper as material which is 32.84 W. By using ANSYS-CFX software, the heat exchanger’s designs were simulated with two thermal conditions which are steady state conduction and transient conduction by substituting material between copper and aluminium to see the engagement between theoretical analysis and numerical analysis. There are three inlet temperatures that are assumed will be supplied by constant waste heat which are 200°C, 350°C and 500°C. The simulation on both steady state and transient condition found the copper is better in thermal or heat conductor than aluminium due to high value of thermal conductivity, k. In terms of design, startype heat exchanger recorded the fastest time to distribute temperature compared to wiretype and fingertype heat exchanger. As a conclusion, the combination between startype design and copper material will produce the best heat exchanger that will be used in experimental test of thermoacoustic system. 2013-06 Thesis http://eprints.uthm.edu.my/6702/ http://eprints.uthm.edu.my/6702/1/24p%20MOHD%20ZUBIR%20YAHAYA.pdf text en public http://eprints.uthm.edu.my/6702/2/MOHD%20ZUBIR%20YAHAYA%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/6702/3/MOHD%20ZUBIR%20YAHAYA%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Malaysia Fakulti Kejuruteraan Mekanikal dan Pembuatan
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TJ Mechanical engineering and machinery
TJ255-265 Heat engines
spellingShingle TJ Mechanical engineering and machinery
TJ255-265 Heat engines
Yahaya, Mohd Zubir
Evaluation of heat exchanger on thermoacoustic performance
description Thermoacoustic devices have the potential to provide electricity from waste heat to more efficiently use energy resources and to provide new access to electricity for millions of persons around the world. There are many factor influence thermoacoustic performance and this study was focused on a new design of thermoacoustic’s heat exchanger and evaluation of its performance in terms of thermal analysis. Through several ideas from researchers in this field, this study was produced with three designs of heat exchangers which are wiretype, fingertype and startype that specifically one of them will be used in experimental test later. Theoretical analysis shows that heat conduction through a full body of heat exchanger are 67.36 W and 39.81 W for both copper and aluminium. Analyzing heat conduction of a fin separately by types of heat exchangers, the highest value of heat conduction through a fin was recorded by startype heat exchanger’s fin using copper as material which is 32.84 W. By using ANSYS-CFX software, the heat exchanger’s designs were simulated with two thermal conditions which are steady state conduction and transient conduction by substituting material between copper and aluminium to see the engagement between theoretical analysis and numerical analysis. There are three inlet temperatures that are assumed will be supplied by constant waste heat which are 200°C, 350°C and 500°C. The simulation on both steady state and transient condition found the copper is better in thermal or heat conductor than aluminium due to high value of thermal conductivity, k. In terms of design, startype heat exchanger recorded the fastest time to distribute temperature compared to wiretype and fingertype heat exchanger. As a conclusion, the combination between startype design and copper material will produce the best heat exchanger that will be used in experimental test of thermoacoustic system.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Yahaya, Mohd Zubir
author_facet Yahaya, Mohd Zubir
author_sort Yahaya, Mohd Zubir
title Evaluation of heat exchanger on thermoacoustic performance
title_short Evaluation of heat exchanger on thermoacoustic performance
title_full Evaluation of heat exchanger on thermoacoustic performance
title_fullStr Evaluation of heat exchanger on thermoacoustic performance
title_full_unstemmed Evaluation of heat exchanger on thermoacoustic performance
title_sort evaluation of heat exchanger on thermoacoustic performance
granting_institution Universiti Tun Hussein Malaysia
granting_department Fakulti Kejuruteraan Mekanikal dan Pembuatan
publishDate 2013
url http://eprints.uthm.edu.my/6702/1/24p%20MOHD%20ZUBIR%20YAHAYA.pdf
http://eprints.uthm.edu.my/6702/2/MOHD%20ZUBIR%20YAHAYA%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/6702/3/MOHD%20ZUBIR%20YAHAYA%20WATERMARK.pdf
_version_ 1747831084324749312