Current transformer performance in high voltage and low voltage systems

Current Transformers (CT's) are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. Current transformer provide isolation from the high voltage primary, permit grounding of the secondary for safety, and step-down the...

Full description

Saved in:
Bibliographic Details
Main Author: Abd Aziz, Muhammad Khairul Arifin
Format: Thesis
Language:English
English
English
Published: 2008
Subjects:
Online Access:http://eprints.uthm.edu.my/7083/1/24p%20MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ.pdf
http://eprints.uthm.edu.my/7083/2/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7083/3/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.7083
record_format uketd_dc
spelling my-uthm-ep.70832022-05-30T00:40:23Z Current transformer performance in high voltage and low voltage systems 2008-04 Abd Aziz, Muhammad Khairul Arifin TK Electrical engineering. Electronics Nuclear engineering TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Current Transformers (CT's) are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. Current transformer provide isolation from the high voltage primary, permit grounding of the secondary for safety, and step-down the magnitude of the measured current to a value that can be safely handled by the instruments. It is one of the critical protective devices in a high voltage substation and low voltage switch board. It is used as a sensor to detect faults that will generate signal to trip the protective relay. The performance of current transformer is very important in preventive and predictive maintenance. It can reduce number of injury and minimize system and equipment failure as well as help to reduce the cost. In this work, the method of measuring and testing the electrical characteristics of CT's are first investigated and the experience gained in the measurement and testing are then used to check and verify the characteristics of CT's found the low voltage switchboard of the Electrical Installation lab. The procedures and steps involved in the measurement and testing are reported and discussed in this work. The method of measurement in the low voltage switchboard are also reported and discussed in this work. 2008-04 Thesis http://eprints.uthm.edu.my/7083/ http://eprints.uthm.edu.my/7083/1/24p%20MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ.pdf text en public http://eprints.uthm.edu.my/7083/2/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/7083/3/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TK Electrical engineering
Electronics Nuclear engineering
TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
TK Electrical engineering
Electronics Nuclear engineering
Abd Aziz, Muhammad Khairul Arifin
Current transformer performance in high voltage and low voltage systems
description Current Transformers (CT's) are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. Current transformer provide isolation from the high voltage primary, permit grounding of the secondary for safety, and step-down the magnitude of the measured current to a value that can be safely handled by the instruments. It is one of the critical protective devices in a high voltage substation and low voltage switch board. It is used as a sensor to detect faults that will generate signal to trip the protective relay. The performance of current transformer is very important in preventive and predictive maintenance. It can reduce number of injury and minimize system and equipment failure as well as help to reduce the cost. In this work, the method of measuring and testing the electrical characteristics of CT's are first investigated and the experience gained in the measurement and testing are then used to check and verify the characteristics of CT's found the low voltage switchboard of the Electrical Installation lab. The procedures and steps involved in the measurement and testing are reported and discussed in this work. The method of measurement in the low voltage switchboard are also reported and discussed in this work.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Abd Aziz, Muhammad Khairul Arifin
author_facet Abd Aziz, Muhammad Khairul Arifin
author_sort Abd Aziz, Muhammad Khairul Arifin
title Current transformer performance in high voltage and low voltage systems
title_short Current transformer performance in high voltage and low voltage systems
title_full Current transformer performance in high voltage and low voltage systems
title_fullStr Current transformer performance in high voltage and low voltage systems
title_full_unstemmed Current transformer performance in high voltage and low voltage systems
title_sort current transformer performance in high voltage and low voltage systems
granting_institution Universiti Tun Hussein Malaysia
granting_department Fakulti Kejuruteraan Elektrik dan Elektronik
publishDate 2008
url http://eprints.uthm.edu.my/7083/1/24p%20MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ.pdf
http://eprints.uthm.edu.my/7083/2/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7083/3/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20WATERMARK.pdf
_version_ 1747831108748181504