Current transformer performance in high voltage and low voltage systems
Current Transformers (CT's) are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. Current transformer provide isolation from the high voltage primary, permit grounding of the secondary for safety, and step-down the...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English English |
Published: |
2008
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/7083/1/24p%20MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ.pdf http://eprints.uthm.edu.my/7083/2/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/7083/3/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20WATERMARK.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uthm-ep.7083 |
---|---|
record_format |
uketd_dc |
spelling |
my-uthm-ep.70832022-05-30T00:40:23Z Current transformer performance in high voltage and low voltage systems 2008-04 Abd Aziz, Muhammad Khairul Arifin TK Electrical engineering. Electronics Nuclear engineering TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Current Transformers (CT's) are instrument transformers that are used to supply a reduced value of current to meters, protective relays, and other instruments. Current transformer provide isolation from the high voltage primary, permit grounding of the secondary for safety, and step-down the magnitude of the measured current to a value that can be safely handled by the instruments. It is one of the critical protective devices in a high voltage substation and low voltage switch board. It is used as a sensor to detect faults that will generate signal to trip the protective relay. The performance of current transformer is very important in preventive and predictive maintenance. It can reduce number of injury and minimize system and equipment failure as well as help to reduce the cost. In this work, the method of measuring and testing the electrical characteristics of CT's are first investigated and the experience gained in the measurement and testing are then used to check and verify the characteristics of CT's found the low voltage switchboard of the Electrical Installation lab. The procedures and steps involved in the measurement and testing are reported and discussed in this work. The method of measurement in the low voltage switchboard are also reported and discussed in this work. 2008-04 Thesis http://eprints.uthm.edu.my/7083/ http://eprints.uthm.edu.my/7083/1/24p%20MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ.pdf text en public http://eprints.uthm.edu.my/7083/2/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/7083/3/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik |
institution |
Universiti Tun Hussein Onn Malaysia |
collection |
UTHM Institutional Repository |
language |
English English English |
topic |
TK Electrical engineering Electronics Nuclear engineering TK Electrical engineering Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering Electronics Nuclear engineering TK Electrical engineering Electronics Nuclear engineering Abd Aziz, Muhammad Khairul Arifin Current transformer performance in high voltage and low voltage systems |
description |
Current Transformers (CT's) are instrument transformers that are used to supply
a reduced value of current to meters, protective relays, and other instruments. Current
transformer provide isolation from the high voltage primary, permit grounding of the
secondary for safety, and step-down the magnitude of the measured current to a value
that can be safely handled by the instruments. It is one of the critical protective devices
in a high voltage substation and low voltage switch board. It is used as a sensor to detect
faults that will generate signal to trip the protective relay. The performance of current
transformer is very important in preventive and predictive maintenance. It can reduce
number of injury and minimize system and equipment failure as well as help to reduce
the cost. In this work, the method of measuring and testing the electrical characteristics
of CT's are first investigated and the experience gained in the measurement and testing
are then used to check and verify the characteristics of CT's found the low voltage
switchboard of the Electrical Installation lab. The procedures and steps involved in the
measurement and testing are reported and discussed in this work. The method of
measurement in the low voltage switchboard are also reported and discussed in this work. |
format |
Thesis |
qualification_name |
Master of Philosophy (M.Phil.) |
qualification_level |
Master's degree |
author |
Abd Aziz, Muhammad Khairul Arifin |
author_facet |
Abd Aziz, Muhammad Khairul Arifin |
author_sort |
Abd Aziz, Muhammad Khairul Arifin |
title |
Current transformer performance in high voltage and low voltage systems |
title_short |
Current transformer performance in high voltage and low voltage systems |
title_full |
Current transformer performance in high voltage and low voltage systems |
title_fullStr |
Current transformer performance in high voltage and low voltage systems |
title_full_unstemmed |
Current transformer performance in high voltage and low voltage systems |
title_sort |
current transformer performance in high voltage and low voltage systems |
granting_institution |
Universiti Tun Hussein Malaysia |
granting_department |
Fakulti Kejuruteraan Elektrik dan Elektronik |
publishDate |
2008 |
url |
http://eprints.uthm.edu.my/7083/1/24p%20MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ.pdf http://eprints.uthm.edu.my/7083/2/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/7083/3/MUHAMMAD%20KHAIRUL%20ARIFIN%20ABD%20AZIZ%20WATERMARK.pdf |
_version_ |
1747831108748181504 |