Alarm design for SCADA system of assembly CELL-200 trainer

Alarm systems play a vital role in maintaining the safe operation in process plant. Moreover, the safety and efficiency of a plant's operation is assured by the usage of a reliable and user friendly alarm system. In this project, the main objective is to introduce an alarm feature inside the...

Full description

Saved in:
Bibliographic Details
Main Author: Zawawi, Mukmin
Format: Thesis
Language:English
English
English
Published: 2008
Subjects:
Online Access:http://eprints.uthm.edu.my/7084/1/24p%20MUKMIN%20ZAWAWI.pdf
http://eprints.uthm.edu.my/7084/2/MUKMIN%20ZAWAWI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7084/3/MUKMIN%20ZAWAWI%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.7084
record_format uketd_dc
spelling my-uthm-ep.70842022-05-30T00:40:39Z Alarm design for SCADA system of assembly CELL-200 trainer 2008-04 Zawawi, Mukmin TJ Mechanical engineering and machinery TJ212-225 Control engineering systems. Automatic machinery (General) Alarm systems play a vital role in maintaining the safe operation in process plant. Moreover, the safety and efficiency of a plant's operation is assured by the usage of a reliable and user friendly alarm system. In this project, the main objective is to introduce an alarm feature inside the SCADA system. Identification of suitable guidelines in designing a good alarm system display is also part of the project's objective. Introduction of alarm feature inside the SCADA system is done by putting the Supervisory Control and Data Acquisition (SCADA) system to Assembly Cell-200 Trainer. Here, the SCADA system is equipped with an alarm system as the mean to monitor and control the trainer. The alarm design adopts the available alarm system guidelines as to figure out and judge the most suitable guidelines to be applied in this project. This exercise proves that general guidelines (e.g., use of an alarm philosophy) are essential in developing this projects. However, detailed guidelines (e.g., colour coding and symbol features) should be used more carefully and consistent to ensure the creation of understandable and recognizable display. From this project, a properly designed alarm system is developed, which provides the operators with enough information to prevent any abnormalities, fault conditions or undesired errors in the plant. This project also summarizes the principal guidelines to consider when designing and developing alarms in SCADA environment. 2008-04 Thesis http://eprints.uthm.edu.my/7084/ http://eprints.uthm.edu.my/7084/1/24p%20MUKMIN%20ZAWAWI.pdf text en public http://eprints.uthm.edu.my/7084/2/MUKMIN%20ZAWAWI%20COPYRIGHT%20DECLARATION.pdf text en validuser http://eprints.uthm.edu.my/7084/3/MUKMIN%20ZAWAWI%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TJ Mechanical engineering and machinery
TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
TJ Mechanical engineering and machinery
Zawawi, Mukmin
Alarm design for SCADA system of assembly CELL-200 trainer
description Alarm systems play a vital role in maintaining the safe operation in process plant. Moreover, the safety and efficiency of a plant's operation is assured by the usage of a reliable and user friendly alarm system. In this project, the main objective is to introduce an alarm feature inside the SCADA system. Identification of suitable guidelines in designing a good alarm system display is also part of the project's objective. Introduction of alarm feature inside the SCADA system is done by putting the Supervisory Control and Data Acquisition (SCADA) system to Assembly Cell-200 Trainer. Here, the SCADA system is equipped with an alarm system as the mean to monitor and control the trainer. The alarm design adopts the available alarm system guidelines as to figure out and judge the most suitable guidelines to be applied in this project. This exercise proves that general guidelines (e.g., use of an alarm philosophy) are essential in developing this projects. However, detailed guidelines (e.g., colour coding and symbol features) should be used more carefully and consistent to ensure the creation of understandable and recognizable display. From this project, a properly designed alarm system is developed, which provides the operators with enough information to prevent any abnormalities, fault conditions or undesired errors in the plant. This project also summarizes the principal guidelines to consider when designing and developing alarms in SCADA environment.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Zawawi, Mukmin
author_facet Zawawi, Mukmin
author_sort Zawawi, Mukmin
title Alarm design for SCADA system of assembly CELL-200 trainer
title_short Alarm design for SCADA system of assembly CELL-200 trainer
title_full Alarm design for SCADA system of assembly CELL-200 trainer
title_fullStr Alarm design for SCADA system of assembly CELL-200 trainer
title_full_unstemmed Alarm design for SCADA system of assembly CELL-200 trainer
title_sort alarm design for scada system of assembly cell-200 trainer
granting_institution Universiti Tun Hussein Malaysia
granting_department Fakulti Kejuruteraan Elektrik dan Elektronik
publishDate 2008
url http://eprints.uthm.edu.my/7084/1/24p%20MUKMIN%20ZAWAWI.pdf
http://eprints.uthm.edu.my/7084/2/MUKMIN%20ZAWAWI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7084/3/MUKMIN%20ZAWAWI%20WATERMARK.pdf
_version_ 1747831108995645440