Condition monitoring of electric motor
Condition monitoring on electric motor is a preventive maintenance in order to avoid problems and hazard from happening to the machinery, also to prevent personal injury with the major factor is insulation resistance. In this thesis, to further discuss this issue, the developed experiment with th...
Saved in:
主要作者: | |
---|---|
格式: | Thesis |
語言: | English English English |
出版: |
2007
|
主題: | |
在線閱讀: | http://eprints.uthm.edu.my/7104/1/24p%20ZURAIDAH%20NGADIRON.pdf http://eprints.uthm.edu.my/7104/2/ZURAIDAH%20NGADIRON%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/7104/3/ZURAIDAH%20NGADIRON%20WATERMARK.pdf |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
總結: | Condition monitoring on electric motor is a preventive maintenance in order to
avoid problems and hazard from happening to the machinery, also to prevent personal
injury with the major factor is insulation resistance. In this thesis, to further discuss this
issue, the developed experiment with the measuring technique of the condition of
electric motor on insulation resistance is used. Then, the experiment rig was developed
applied to Thrige Odense Denmark 3-phase induction motor for case stud} to obserxe
the condition monitoring on insulation resistance. The validity of the data was then taken
using the megohmmeter and temperature indicator. The experiment is to monitor the
Denmark manufactured motor condition of insulation whether is good. fair, poor or bad
by following the IEEE standard procedure. This prexentixe maintenance test can be done
on a monthlx. semiannual or annual basis as conditions demand. The data from the test
is plotted to graph to get the trended data of the insulation. The theoretical and
experiment studies include the effect of the humiditx and temperature to the insulation.
Tests rig for the experimental work are developed using IEEE Standard 43-2000. IEEE
Recommended Practice for Testing Insulation Resistance of Rotating Machinery and A
Guide To Diagnostic Insulation Testing Above lkV by Megger Ltd. Second Edition
2002. The results have been compared to the standard and analyses are presented in
graph. From the developed procedure and methods prove that the temperature affects the
insulation winding at 3-phase induction motor (2 speed : 2 winding). For case study, the
motor has been soaked for three days to apply flooded condition. The result shows that
the motor insulation condition is even better after comparison with the standard
manufactured data at 821 MH and 893 MH change to more than 999 Mfi for both
winding condition after drying out experiment. |
---|