Field estimation of induction motor performance using dynamometer method and equivalent circuit method
Three phase AC induction motors are ideal for most industrial and agricultural applications because of their simple construction, low maintenance and robustness in field conditions. With varying load requirements, the performance of the motor also varies in terms of torque, efficiency and powe...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English English |
Published: |
2008
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/7354/1/24p%20MOHD%20HISYAM%20MOHD%20ARIFF.pdf http://eprints.uthm.edu.my/7354/2/MOHD%20HISYAM%20MOHD%20ARIFF%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/7354/3/MOHD%20HISYAM%20MOHD%20ARIFF%20WATERMARK.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uthm-ep.7354 |
---|---|
record_format |
uketd_dc |
spelling |
my-uthm-ep.73542022-07-21T04:11:16Z Field estimation of induction motor performance using dynamometer method and equivalent circuit method 2008-11 Mohd Ariff, Mohd Hisyam TK Electrical engineering. Electronics Nuclear engineering TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Three phase AC induction motors are ideal for most industrial and agricultural applications because of their simple construction, low maintenance and robustness in field conditions. With varying load requirements, the performance of the motor also varies in terms of torque, efficiency and power factor. The induction motor's performance characteristics provide important information to the motor designer and also to the actual users for evaluating operating costs and monitoring motor performance under actual load conditions. Realizing the importance of motor performance information in practice, this project aimed to investigate and improve the standard motor tests that predict motor performance so that it can be done quickly, easily and accurately. The first method is based on the dynamometer approach and the second is concerned with obtaining the motor's equivalent circuit parameters from basic tests. The performance of the motor in terms of torque, efficiency and power factor is then calculated from the equivalent circuit. The validity of the test methodology was verified by comparing the results of analysis with data of a motor from a catalogue with the results of dynamometer instrument in the laboratory. Also carried out in this project was motor performance analysis using GUI performance calculator which was developed using Matlab software. The results from the methods used were then compared in term of ease of implementation and accuracy achieved. 2008-11 Thesis http://eprints.uthm.edu.my/7354/ http://eprints.uthm.edu.my/7354/1/24p%20MOHD%20HISYAM%20MOHD%20ARIFF.pdf text en public http://eprints.uthm.edu.my/7354/2/MOHD%20HISYAM%20MOHD%20ARIFF%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/7354/3/MOHD%20HISYAM%20MOHD%20ARIFF%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik |
institution |
Universiti Tun Hussein Onn Malaysia |
collection |
UTHM Institutional Repository |
language |
English English English |
topic |
TK Electrical engineering Electronics Nuclear engineering TK Electrical engineering Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering Electronics Nuclear engineering TK Electrical engineering Electronics Nuclear engineering Mohd Ariff, Mohd Hisyam Field estimation of induction motor performance using dynamometer method and equivalent circuit method |
description |
Three phase AC induction motors are ideal for most industrial and agricultural
applications because of their simple construction, low maintenance and robustness in
field conditions. With varying load requirements, the performance of the motor also
varies in terms of torque, efficiency and power factor. The induction motor's
performance characteristics provide important information to the motor designer and
also to the actual users for evaluating operating costs and monitoring motor performance
under actual load conditions. Realizing the importance of motor performance
information in practice, this project aimed to investigate and improve the standard motor
tests that predict motor performance so that it can be done quickly, easily and accurately.
The first method is based on the dynamometer approach and the second is
concerned with obtaining the motor's equivalent circuit parameters from basic tests. The
performance of the motor in terms of torque, efficiency and power factor is then
calculated from the equivalent circuit. The validity of the test methodology was verified
by comparing the results of analysis with data of a motor from a catalogue with the
results of dynamometer instrument in the laboratory.
Also carried out in this project was motor performance analysis using GUI
performance calculator which was developed using Matlab software. The results from
the methods used were then compared in term of ease of implementation and accuracy
achieved. |
format |
Thesis |
qualification_name |
Master of Philosophy (M.Phil.) |
qualification_level |
Master's degree |
author |
Mohd Ariff, Mohd Hisyam |
author_facet |
Mohd Ariff, Mohd Hisyam |
author_sort |
Mohd Ariff, Mohd Hisyam |
title |
Field estimation of induction motor performance using dynamometer method and equivalent circuit method |
title_short |
Field estimation of induction motor performance using dynamometer method and equivalent circuit method |
title_full |
Field estimation of induction motor performance using dynamometer method and equivalent circuit method |
title_fullStr |
Field estimation of induction motor performance using dynamometer method and equivalent circuit method |
title_full_unstemmed |
Field estimation of induction motor performance using dynamometer method and equivalent circuit method |
title_sort |
field estimation of induction motor performance using dynamometer method and equivalent circuit method |
granting_institution |
Universiti Tun Hussein Onn Malaysia |
granting_department |
Fakulti Kejuruteraan Elektrik dan Elektronik |
publishDate |
2008 |
url |
http://eprints.uthm.edu.my/7354/1/24p%20MOHD%20HISYAM%20MOHD%20ARIFF.pdf http://eprints.uthm.edu.my/7354/2/MOHD%20HISYAM%20MOHD%20ARIFF%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/7354/3/MOHD%20HISYAM%20MOHD%20ARIFF%20WATERMARK.pdf |
_version_ |
1747831138159689728 |