Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction

A typical building zone designated as Zone PPU, in UTHM was selected for a detailed study of applying Thermal Energy Storage (TES) for cooling load reduction. Data of electricity bills from May 2005 to December 2007 were collected for analysis of usage trending. The energy consumption index fo...

Full description

Saved in:
Bibliographic Details
Main Author: Tee, Swee Yin
Format: Thesis
Language:English
English
English
Published: 2008
Subjects:
Online Access:http://eprints.uthm.edu.my/7465/1/24p%20TEE%20SWEE%20YIN.pdf
http://eprints.uthm.edu.my/7465/2/TEE%20SWEE%20YIN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7465/3/TEE%20SWEE%20YIN%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.7465
record_format uketd_dc
spelling my-uthm-ep.74652022-07-24T03:49:46Z Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction 2008-11 Tee, Swee Yin TJ Mechanical engineering and machinery TJ255-265 Heat engines A typical building zone designated as Zone PPU, in UTHM was selected for a detailed study of applying Thermal Energy Storage (TES) for cooling load reduction. Data of electricity bills from May 2005 to December 2007 were collected for analysis of usage trending. The energy consumption index for Zone PPU was also established and compared with MS 1525 standard. The energy simulation program TRACE 700 was used to calculate the peak cooling loads for Zone PPU. Two storage systems using ice storage technology were being proposed in this study, which are full storage system and partial storage system. Two economical analysis tools, which are the Simple Payback Period method and Net Present Value method, were used to evaluate whether the proposals are economically viable to be considered. The energy consumption for buildings G I, G2 and G3 (of total floor areas 15,285 m2 ) for the year 2007 was 7,261 ,803kWh, giving an energy consumption index of 475kWh/nl per year which was far too much compared to the recommended value of 135kWh/m2 per year as stated in MS 1525 Standard. The analysis results indicated that the TES proposals for the existing cooling load of I 160RT has no attractive payback period and results negative net present value calculating up to the life span (of 15 years) of chillers with proper maintenance, indicating that the TES proposal is not economically viable. In view of the available market references, cooling load of 3000RT and above is required in order to achieve a more economically viable proposal. Therefore, several proposals with proposed capacity ranging from 2200RT, 2900RT, 3600RT and 4200RT have been made so that the most optimum load can be selected for future considerations. 2008-11 Thesis http://eprints.uthm.edu.my/7465/ http://eprints.uthm.edu.my/7465/1/24p%20TEE%20SWEE%20YIN.pdf text en public http://eprints.uthm.edu.my/7465/2/TEE%20SWEE%20YIN%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/7465/3/TEE%20SWEE%20YIN%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Mekanikal dan Pembuatan
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TJ Mechanical engineering and machinery
TJ255-265 Heat engines
spellingShingle TJ Mechanical engineering and machinery
TJ255-265 Heat engines
Tee, Swee Yin
Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction
description A typical building zone designated as Zone PPU, in UTHM was selected for a detailed study of applying Thermal Energy Storage (TES) for cooling load reduction. Data of electricity bills from May 2005 to December 2007 were collected for analysis of usage trending. The energy consumption index for Zone PPU was also established and compared with MS 1525 standard. The energy simulation program TRACE 700 was used to calculate the peak cooling loads for Zone PPU. Two storage systems using ice storage technology were being proposed in this study, which are full storage system and partial storage system. Two economical analysis tools, which are the Simple Payback Period method and Net Present Value method, were used to evaluate whether the proposals are economically viable to be considered. The energy consumption for buildings G I, G2 and G3 (of total floor areas 15,285 m2 ) for the year 2007 was 7,261 ,803kWh, giving an energy consumption index of 475kWh/nl per year which was far too much compared to the recommended value of 135kWh/m2 per year as stated in MS 1525 Standard. The analysis results indicated that the TES proposals for the existing cooling load of I 160RT has no attractive payback period and results negative net present value calculating up to the life span (of 15 years) of chillers with proper maintenance, indicating that the TES proposal is not economically viable. In view of the available market references, cooling load of 3000RT and above is required in order to achieve a more economically viable proposal. Therefore, several proposals with proposed capacity ranging from 2200RT, 2900RT, 3600RT and 4200RT have been made so that the most optimum load can be selected for future considerations.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Tee, Swee Yin
author_facet Tee, Swee Yin
author_sort Tee, Swee Yin
title Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction
title_short Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction
title_full Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction
title_fullStr Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction
title_full_unstemmed Energy efficient building: the application of thermal energy storage (TES) for cooling load reduction
title_sort energy efficient building: the application of thermal energy storage (tes) for cooling load reduction
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Fakulti Kejuruteraan Mekanikal dan Pembuatan
publishDate 2008
url http://eprints.uthm.edu.my/7465/1/24p%20TEE%20SWEE%20YIN.pdf
http://eprints.uthm.edu.my/7465/2/TEE%20SWEE%20YIN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7465/3/TEE%20SWEE%20YIN%20WATERMARK.pdf
_version_ 1747831156543324160