Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling

Film cooling method was applied to the turbine blades to provide thermal protection from high turbine inlet temperatures in modern gas turbines. Recent literature discovers that combining two cylindrical holes of film cooling is one of the ways to further enhance the film cooling performances....

全面介紹

Saved in:
書目詳細資料
主要作者: Hassan, Haswira
格式: Thesis
語言:English
English
English
出版: 2016
主題:
在線閱讀:http://eprints.uthm.edu.my/751/1/24p%20HASWIRA%20HASSAN.pdf
http://eprints.uthm.edu.my/751/2/HASWIRA%20HASSAN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/751/3/HASWIRA%20HASSAN%20WATERMARK.pdf
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my-uthm-ep.751
record_format uketd_dc
spelling my-uthm-ep.7512021-08-30T07:49:40Z Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling 2016-08 Hassan, Haswira TJ751-805 Miscellaneous motors and engines Including gas, gasoline, diesel engines Film cooling method was applied to the turbine blades to provide thermal protection from high turbine inlet temperatures in modern gas turbines. Recent literature discovers that combining two cylindrical holes of film cooling is one of the ways to further enhance the film cooling performances. In the present study, a batch of simulations and experiments involving two cylindrical holes with opposite compound angle were carried out and this two cylindrical hole also known as combined-hole film cooling. The main objective of this study is to determine the influence of different blowing ratio, M with a combination of different lateral distance between cooling holes (PoD), a streamwise distance between cooling holes (LoD) and compound angle of cooling hole (1/2) on the film cooling performance. The simulation of the present study had been carried out by using Computational Fluid Dynamic (CFD) with application of Shear Stress Transport (SST) turbulence model analysis from ANSYS CFX. Meanwhile, the experimental approach makes used of open end wind tunnel and the temperature distributions were measured by using infrared thermography camera. The purpose of the experimental approach in the present study is to validate three cases from all cases considered in the simulation approach. As the results shown, the lateral coverage was observed to be increased as PoD and 1/2 increased due to the interaction between two cooling air ejected from both cooling holes. Meanwhile, film cooling performance insignificantly changed when different LoD was applied. As the conclusion, a combination of the different geometrical parameters with various flow parameters produced a pattern of results. Therefore, the best configuration has been determined based on the average area of film cooling effectiveness. For M = 0.5, PoD = 1.0, LoD = 2.5 and 1 / 2 = -45o /+45o case is the most effective configuration. In the case of M = 1.0 and M = 1.5, PoD = 0.0, LoD = 3.5, 1 / 2 = -45o /+45o and PoD = 0.0, LoD = 2.5, 1 / 2 = -45o /+30o are the best configurations based on the overall performance of film cooling. 2016-08 Thesis http://eprints.uthm.edu.my/751/ http://eprints.uthm.edu.my/751/1/24p%20HASWIRA%20HASSAN.pdf text en public http://eprints.uthm.edu.my/751/2/HASWIRA%20HASSAN%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/751/3/HASWIRA%20HASSAN%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Mekanikal dan Pembuatan
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TJ751-805 Miscellaneous motors and engines Including gas
gasoline
diesel engines
spellingShingle TJ751-805 Miscellaneous motors and engines Including gas
gasoline
diesel engines
Hassan, Haswira
Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling
description Film cooling method was applied to the turbine blades to provide thermal protection from high turbine inlet temperatures in modern gas turbines. Recent literature discovers that combining two cylindrical holes of film cooling is one of the ways to further enhance the film cooling performances. In the present study, a batch of simulations and experiments involving two cylindrical holes with opposite compound angle were carried out and this two cylindrical hole also known as combined-hole film cooling. The main objective of this study is to determine the influence of different blowing ratio, M with a combination of different lateral distance between cooling holes (PoD), a streamwise distance between cooling holes (LoD) and compound angle of cooling hole (1/2) on the film cooling performance. The simulation of the present study had been carried out by using Computational Fluid Dynamic (CFD) with application of Shear Stress Transport (SST) turbulence model analysis from ANSYS CFX. Meanwhile, the experimental approach makes used of open end wind tunnel and the temperature distributions were measured by using infrared thermography camera. The purpose of the experimental approach in the present study is to validate three cases from all cases considered in the simulation approach. As the results shown, the lateral coverage was observed to be increased as PoD and 1/2 increased due to the interaction between two cooling air ejected from both cooling holes. Meanwhile, film cooling performance insignificantly changed when different LoD was applied. As the conclusion, a combination of the different geometrical parameters with various flow parameters produced a pattern of results. Therefore, the best configuration has been determined based on the average area of film cooling effectiveness. For M = 0.5, PoD = 1.0, LoD = 2.5 and 1 / 2 = -45o /+45o case is the most effective configuration. In the case of M = 1.0 and M = 1.5, PoD = 0.0, LoD = 3.5, 1 / 2 = -45o /+45o and PoD = 0.0, LoD = 2.5, 1 / 2 = -45o /+30o are the best configurations based on the overall performance of film cooling.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Hassan, Haswira
author_facet Hassan, Haswira
author_sort Hassan, Haswira
title Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling
title_short Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling
title_full Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling
title_fullStr Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling
title_full_unstemmed Experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling
title_sort experimental and simulation study on the effect of geometrical and flow parameters for combined-hole film cooling
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Fakulti Kejuruteraan Mekanikal dan Pembuatan
publishDate 2016
url http://eprints.uthm.edu.my/751/1/24p%20HASWIRA%20HASSAN.pdf
http://eprints.uthm.edu.my/751/2/HASWIRA%20HASSAN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/751/3/HASWIRA%20HASSAN%20WATERMARK.pdf
_version_ 1747830674091409408