Non-CFC refrigerants: first and second law efficienies
Concern about the ozone depletion and green house effects caused by refrigerants have initiated and continued studies into more environmentally friendly refrigerants. This study looked into the performance of these refrigerants in terms of second law efficiency, COP, irreversibility, and disch...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2002
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/7758/2/24p%20SIA%20CHEE%20KIONG.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uthm-ep.7758 |
---|---|
record_format |
uketd_dc |
spelling |
my-uthm-ep.77582022-10-05T07:19:38Z Non-CFC refrigerants: first and second law efficienies 2002-03 Sia, Chee Kiong TP Chemical technology TP480-498 Low temperature engineering. Cryogenic engineering. Refrigeration Concern about the ozone depletion and green house effects caused by refrigerants have initiated and continued studies into more environmentally friendly refrigerants. This study looked into the performance of these refrigerants in terms of second law efficiency, COP, irreversibility, and discharge temperature. A program based on Visual Basic has been developed that can quantify the parameters above and this can be used to guide industrialists in their efforts to build or retrofit systems with new refrigerants. Results from the simulation have shown that R134a is potentially good as a replacement for R12, R402a for R502, and R407c for R22. 2002-03 Thesis http://eprints.uthm.edu.my/7758/ http://eprints.uthm.edu.my/7758/2/24p%20SIA%20CHEE%20KIONG.pdf text en public mphil masters Universiti Teknologi Malaysia Fakulti Kejuruteraan Mekanikal |
institution |
Universiti Tun Hussein Onn Malaysia |
collection |
UTHM Institutional Repository |
language |
English |
topic |
TP Chemical technology TP Chemical technology |
spellingShingle |
TP Chemical technology TP Chemical technology Sia, Chee Kiong Non-CFC refrigerants: first and second law efficienies |
description |
Concern about the ozone depletion and green house effects caused by
refrigerants have initiated and continued studies into more environmentally friendly
refrigerants. This study looked into the performance of these refrigerants in terms of
second law efficiency, COP, irreversibility, and discharge temperature. A program based
on Visual Basic has been developed that can quantify the parameters above and this can
be used to guide industrialists in their efforts to build or retrofit systems with new
refrigerants. Results from the simulation have shown that R134a is potentially good as a
replacement for R12, R402a for R502, and R407c for R22. |
format |
Thesis |
qualification_name |
Master of Philosophy (M.Phil.) |
qualification_level |
Master's degree |
author |
Sia, Chee Kiong |
author_facet |
Sia, Chee Kiong |
author_sort |
Sia, Chee Kiong |
title |
Non-CFC refrigerants: first and second law efficienies |
title_short |
Non-CFC refrigerants: first and second law efficienies |
title_full |
Non-CFC refrigerants: first and second law efficienies |
title_fullStr |
Non-CFC refrigerants: first and second law efficienies |
title_full_unstemmed |
Non-CFC refrigerants: first and second law efficienies |
title_sort |
non-cfc refrigerants: first and second law efficienies |
granting_institution |
Universiti Teknologi Malaysia |
granting_department |
Fakulti Kejuruteraan Mekanikal |
publishDate |
2002 |
url |
http://eprints.uthm.edu.my/7758/2/24p%20SIA%20CHEE%20KIONG.pdf |
_version_ |
1747831190266576896 |