Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line

A cloud-to-ground lightning activity data collected by a Lightning Detection System (LDS) along the 275 kV transmission line KLMK-PROI in year 2004 to 2005 from Seremban to Melaka has been investigated. The LDS are installed by TNB Research Sdn Bhd (TNBR) in 1994. Annual lightning days are acq...

Full description

Saved in:
Bibliographic Details
Main Author: Ali, Mohd Aldrin
Format: Thesis
Language:English
English
English
Published: 2006
Subjects:
Online Access:http://eprints.uthm.edu.my/8192/1/24p%20MOHD%20ALDRIN%20ALI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8192/2/MOHD%20ALDRIN%20ALI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8192/3/MOHD%20ALDRIN%20ALI%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.8192
record_format uketd_dc
spelling my-uthm-ep.81922023-02-07T03:28:43Z Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line 2006-11 Ali, Mohd Aldrin QC Physics QC851-999 Meteorology. Climatology. Including the earth's atmosphere A cloud-to-ground lightning activity data collected by a Lightning Detection System (LDS) along the 275 kV transmission line KLMK-PROI in year 2004 to 2005 from Seremban to Melaka has been investigated. The LDS are installed by TNB Research Sdn Bhd (TNBR) in 1994. Annual lightning days are acquired and ground flash density maps are constructed from the database. Lightning parameters such as, polarity, ground flash density and peak lightning current were analyzed with the lightning data collected by LDS. The lightning data was analyzed using FALLS (Fault Analysis and Lightning Location System) software. It is found that the negative lightning is observed more than the positive lightning. Also found that the value of peak current either negative or positive polarity is about 30 kA. The performance of LDS, especially detection efficiency, was evaluated using the data obtained from transmission line fault and lightning activities along transmission line. It is found detection efficiency is 93.38%. 2006-11 Thesis http://eprints.uthm.edu.my/8192/ http://eprints.uthm.edu.my/8192/1/24p%20MOHD%20ALDRIN%20ALI%20COPYRIGHT%20DECLARATION.pdf text en public http://eprints.uthm.edu.my/8192/2/MOHD%20ALDRIN%20ALI%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/8192/3/MOHD%20ALDRIN%20ALI%20WATERMARK.pdf text en validuser mphil masters Kolej Universiti Teknologi Tun Hussein Onn Fakulti Kejuruteraan Elektrik dan Elektronik
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic QC Physics
QC Physics
spellingShingle QC Physics
QC Physics
Ali, Mohd Aldrin
Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line
description A cloud-to-ground lightning activity data collected by a Lightning Detection System (LDS) along the 275 kV transmission line KLMK-PROI in year 2004 to 2005 from Seremban to Melaka has been investigated. The LDS are installed by TNB Research Sdn Bhd (TNBR) in 1994. Annual lightning days are acquired and ground flash density maps are constructed from the database. Lightning parameters such as, polarity, ground flash density and peak lightning current were analyzed with the lightning data collected by LDS. The lightning data was analyzed using FALLS (Fault Analysis and Lightning Location System) software. It is found that the negative lightning is observed more than the positive lightning. Also found that the value of peak current either negative or positive polarity is about 30 kA. The performance of LDS, especially detection efficiency, was evaluated using the data obtained from transmission line fault and lightning activities along transmission line. It is found detection efficiency is 93.38%.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Ali, Mohd Aldrin
author_facet Ali, Mohd Aldrin
author_sort Ali, Mohd Aldrin
title Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line
title_short Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line
title_full Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line
title_fullStr Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line
title_full_unstemmed Lightning characteristics observed by lightning detection system (LDS) along KLMK-PROI 275 kV transmission line
title_sort lightning characteristics observed by lightning detection system (lds) along klmk-proi 275 kv transmission line
granting_institution Kolej Universiti Teknologi Tun Hussein Onn
granting_department Fakulti Kejuruteraan Elektrik dan Elektronik
publishDate 2006
url http://eprints.uthm.edu.my/8192/1/24p%20MOHD%20ALDRIN%20ALI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8192/2/MOHD%20ALDRIN%20ALI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8192/3/MOHD%20ALDRIN%20ALI%20WATERMARK.pdf
_version_ 1776103297497694208