Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara

The number of fluoroscopy-guided interventional (FGI) procedures has significantly increased recently. The radiology department staff such as the interventional radiologists (IR), medical officers (MO), radiographers and nurses who are involved in FGI procedures are usually working in a controlled a...

Full description

Saved in:
Bibliographic Details
Main Author: Bohari, Asmah
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/101481/1/AsmahBohariPFS2020.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.101481
record_format uketd_dc
spelling my-utm-ep.1014812023-06-21T10:11:14Z Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara 2020 Bohari, Asmah Q Science (General) The number of fluoroscopy-guided interventional (FGI) procedures has significantly increased recently. The radiology department staff such as the interventional radiologists (IR), medical officers (MO), radiographers and nurses who are involved in FGI procedures are usually working in a controlled area and receive doses primarily from scattered radiation off the patient. This was a one-year observation study conducted at the Radiology Department, Institut Kanser Negara (IKN), Putrajaya. Each interventional radiology staff member was given two opticallystimulated luminescence (OSL) dosimeters, used to measure the dose of radiation they received. In this study, two types of OSL dosimeter (OSLD) were used: InLight® XA dosimeter and nanoDot® dosimeter. The effective doses received by the interventional radiology staff after performing 230 FGI procedures were estimated using single and double dosimetry algorithms. Assessment on the interchangeability of the effective dose algorithms shows that both Niklason and Boetticher algorithms strongly supported the absence of statistical significance in the estimated effective doses using the Bland-Altman analysis. The effective dose received by the IRs, MOs, radiographers and nurses with double OSLDs were 9.82, 7.91, 6.42 and 6.02 mSv, respectively. The estimated annual eye dose for IR was 18.32 mSv y-1 and is below the recommended dose limit (20 mSv y-1). Due to the IR’s position on the left side of the patient, the right eye shows a lower dose than the left one. Radiation scattered throughout the FGI room shows the left anterior oblique 90° tube angulation has the highest single peak distribution (28.65 mSv h-1). The single peak distributions for the standard anteroposterior, left anterior oblique 45° and right anterior oblique 45° imaging were 13.32, 22.99 and 17.40 mSv h-1, respectively. Knowledge pertaining to radiation exposure levels is integral in order to avoid adverse risks, particularly amongst staff. It is highly recommended that interventional radiology staff use double OSLDs during FGI procedures in order to determine the occupational dose accurately. 2020 Thesis http://eprints.utm.my/id/eprint/101481/ http://eprints.utm.my/id/eprint/101481/1/AsmahBohariPFS2020.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:145989 phd doctoral Universiti Teknologi Malaysia, Faculty of Science Faculty of Science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic Q Science (General)
spellingShingle Q Science (General)
Bohari, Asmah
Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara
description The number of fluoroscopy-guided interventional (FGI) procedures has significantly increased recently. The radiology department staff such as the interventional radiologists (IR), medical officers (MO), radiographers and nurses who are involved in FGI procedures are usually working in a controlled area and receive doses primarily from scattered radiation off the patient. This was a one-year observation study conducted at the Radiology Department, Institut Kanser Negara (IKN), Putrajaya. Each interventional radiology staff member was given two opticallystimulated luminescence (OSL) dosimeters, used to measure the dose of radiation they received. In this study, two types of OSL dosimeter (OSLD) were used: InLight® XA dosimeter and nanoDot® dosimeter. The effective doses received by the interventional radiology staff after performing 230 FGI procedures were estimated using single and double dosimetry algorithms. Assessment on the interchangeability of the effective dose algorithms shows that both Niklason and Boetticher algorithms strongly supported the absence of statistical significance in the estimated effective doses using the Bland-Altman analysis. The effective dose received by the IRs, MOs, radiographers and nurses with double OSLDs were 9.82, 7.91, 6.42 and 6.02 mSv, respectively. The estimated annual eye dose for IR was 18.32 mSv y-1 and is below the recommended dose limit (20 mSv y-1). Due to the IR’s position on the left side of the patient, the right eye shows a lower dose than the left one. Radiation scattered throughout the FGI room shows the left anterior oblique 90° tube angulation has the highest single peak distribution (28.65 mSv h-1). The single peak distributions for the standard anteroposterior, left anterior oblique 45° and right anterior oblique 45° imaging were 13.32, 22.99 and 17.40 mSv h-1, respectively. Knowledge pertaining to radiation exposure levels is integral in order to avoid adverse risks, particularly amongst staff. It is highly recommended that interventional radiology staff use double OSLDs during FGI procedures in order to determine the occupational dose accurately.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Bohari, Asmah
author_facet Bohari, Asmah
author_sort Bohari, Asmah
title Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara
title_short Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara
title_full Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara
title_fullStr Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara
title_full_unstemmed Personnel dose monitoring during fluoroscopy-guided interventional (FGI) procedures at Institut Kanser Negara
title_sort personnel dose monitoring during fluoroscopy-guided interventional (fgi) procedures at institut kanser negara
granting_institution Universiti Teknologi Malaysia, Faculty of Science
granting_department Faculty of Science
publishDate 2020
url http://eprints.utm.my/id/eprint/101481/1/AsmahBohariPFS2020.pdf
_version_ 1776100708196548608