Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric

Electrocardiography (ECG) is one of the methods used for monitoring the heart condition. There are increasing demands for the development of wearable and flexible ECG systems to be implemented for long term ECG monitoring. In the development of wearable circuits, polymer material has been widely use...

Full description

Saved in:
Bibliographic Details
Main Author: Md. Jusob, Syafiqah
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/101714/1/SyafiqahMdJusohMSBME2021.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.101714
record_format uketd_dc
spelling my-utm-ep.1017142023-07-09T01:11:43Z Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric 2021 Md. Jusob, Syafiqah Q Science (General) TK Electrical engineering. Electronics Nuclear engineering Electrocardiography (ECG) is one of the methods used for monitoring the heart condition. There are increasing demands for the development of wearable and flexible ECG systems to be implemented for long term ECG monitoring. In the development of wearable circuits, polymer material has been widely used to enable the flexibility properties. However, polymer may cause allergy to human skin, and the inability of the polymer to pass through moisture at human skin makes it inappropriate to be used for wearable applications. Cotton fabric is an alternative substrate for the polymer since it is natural, hypoallergenic and able to pass through moisture of human skin. Thus, the objectives of this research were focused on designing and fabricating traces of ECG circuit on cotton fabric; investigating the effects of mechanical characterization on the conductive line; and validating the ECG signal acquisition using the fabricated circuit trace with 0.2 % w/w of graphene oxide ink was used as the conductive material. The fabrication process of conductive line on cotton fabric includes the production of wax impregnated paper, wax transferred from wax impregnated paper onto cotton fabric, pipetting of graphene oxide ink onto the cotton fabric, and reduction of graphene oxide. The resistance of 1.97 kQ was produced in 1 mm wide and 20 mm long conductive line coated with 30 layers of graphene oxide. Two mechanical characterizations were performed on the conductive line; washing and folding tests. In washing test, three solutions were used including distilled water with pH = 7, detergent solutions with pH = 8 and pH = 9. The conductive line remained 84 % after fifth times of washing using distilled water with pH = 7. In folding test, the conductive pattern remained 73 % after tenth times of -180 ° and 180 ° angles of folding. During ECG signal acquisition using cotton fabric-based circuit trace, the features of ECG signal are successfully acquired and displayed. However, there is a 60 Hz electrical noise included in the signal due to the capacitive component in the cotton fabric-based circuit trace. This research acts as a preliminary phase in developing a flexible and fully functional cotton fabric-based ECG monitoring system which can be used for long term ECG monitoring. 2021 Thesis http://eprints.utm.my/id/eprint/101714/ http://eprints.utm.my/id/eprint/101714/1/SyafiqahMdJusohMSBME2021.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:147673 masters Universiti Teknologi Malaysia, Faculty of Engineering - School of Biomedical Engineering & Health Sciences Faculty of Engineering - School of Biomedical Engineering & Health Sciences
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic Q Science (General)
Q Science (General)
spellingShingle Q Science (General)
Q Science (General)
Md. Jusob, Syafiqah
Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric
description Electrocardiography (ECG) is one of the methods used for monitoring the heart condition. There are increasing demands for the development of wearable and flexible ECG systems to be implemented for long term ECG monitoring. In the development of wearable circuits, polymer material has been widely used to enable the flexibility properties. However, polymer may cause allergy to human skin, and the inability of the polymer to pass through moisture at human skin makes it inappropriate to be used for wearable applications. Cotton fabric is an alternative substrate for the polymer since it is natural, hypoallergenic and able to pass through moisture of human skin. Thus, the objectives of this research were focused on designing and fabricating traces of ECG circuit on cotton fabric; investigating the effects of mechanical characterization on the conductive line; and validating the ECG signal acquisition using the fabricated circuit trace with 0.2 % w/w of graphene oxide ink was used as the conductive material. The fabrication process of conductive line on cotton fabric includes the production of wax impregnated paper, wax transferred from wax impregnated paper onto cotton fabric, pipetting of graphene oxide ink onto the cotton fabric, and reduction of graphene oxide. The resistance of 1.97 kQ was produced in 1 mm wide and 20 mm long conductive line coated with 30 layers of graphene oxide. Two mechanical characterizations were performed on the conductive line; washing and folding tests. In washing test, three solutions were used including distilled water with pH = 7, detergent solutions with pH = 8 and pH = 9. The conductive line remained 84 % after fifth times of washing using distilled water with pH = 7. In folding test, the conductive pattern remained 73 % after tenth times of -180 ° and 180 ° angles of folding. During ECG signal acquisition using cotton fabric-based circuit trace, the features of ECG signal are successfully acquired and displayed. However, there is a 60 Hz electrical noise included in the signal due to the capacitive component in the cotton fabric-based circuit trace. This research acts as a preliminary phase in developing a flexible and fully functional cotton fabric-based ECG monitoring system which can be used for long term ECG monitoring.
format Thesis
qualification_level Master's degree
author Md. Jusob, Syafiqah
author_facet Md. Jusob, Syafiqah
author_sort Md. Jusob, Syafiqah
title Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric
title_short Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric
title_full Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric
title_fullStr Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric
title_full_unstemmed Reduced graphene oxide-based electrical circuit trace on flexible cotton fabric
title_sort reduced graphene oxide-based electrical circuit trace on flexible cotton fabric
granting_institution Universiti Teknologi Malaysia, Faculty of Engineering - School of Biomedical Engineering & Health Sciences
granting_department Faculty of Engineering - School of Biomedical Engineering & Health Sciences
publishDate 2021
url http://eprints.utm.my/id/eprint/101714/1/SyafiqahMdJusohMSBME2021.pdf
_version_ 1776100754432458752