Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure

Corrosion become the main concern in structure durability which can result in catastrophic failure. Besides, inadequate or wrong selection of water-cement ratio can cause the insufficient readiness of reinforced concrete structure (RC) to the aggressive environment. This issue might arise due to the...

Full description

Saved in:
Bibliographic Details
Main Author: Hamdan, Norerny Shuhada
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/101779/1/NorernyShuhadaHamdanMSKA2021.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.101779
record_format uketd_dc
spelling my-utm-ep.1017792023-07-13T01:14:06Z Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure 2021 Hamdan, Norerny Shuhada TA Engineering (General). Civil engineering (General) Corrosion become the main concern in structure durability which can result in catastrophic failure. Besides, inadequate or wrong selection of water-cement ratio can cause the insufficient readiness of reinforced concrete structure (RC) to the aggressive environment. This issue might arise due to the material cost saving by reducing the material of concrete and at the same time the quality of concrete might be jeopardized during the construction as the consequences of the acts are untraceable in the early stage. The poor quality of concrete in term of penetrability properties can cause the easiness transport of chloride ions into the internal medium of concrete structure. Therefore, the purpose of this research is to highlight the common and frequent problem on the structure deterioration that often related to the chloride-induced corrosion. The pattern and failure mode of concrete and steel were observed using the secondary data collection method from previous study to analyse the intended various factors that contributed to the corrosion of the RC. After all the possible factors that influence the corrosion was determined, the data comparison were done to study their effect on the chloride penetration that led to the occurrence of corrosion. As a result, water-to-cement (w/c) ratio was the main parameter that highlighted as the main cause of the chloride ions penetration that led to the corrosion of reinforced structure at the first place which eventually end up with structure failure. Different parameters were investigated on the degree of corrosion such as the sodium chloride (NaCl) concentration as aggressive agent, the immersion time, and the intended quality concrete casted. The findings show that the lowest chloride penetration depth was 5 mm with w/c ratio of 0.25, and the highest penetration was at the depth of 33 mm with w/c ratio of 0.55 in 3% NaCl solution for 6 months. It can be seen that when w/c ratio increase by 0.1, the chloride penetration depth will increase to approximately 30 to 60%. This results highly prove that the quality of concrete structure plays a significant role in delaying the chloride-induced corrosion. Moreover, these findings can increase the knowledge and awareness of construction practitioner on the importance of designing the adequate quality of concrete structure and ensure the quality was well-maintained to avoid the economic issue arise in future due to corrosion. 2021 Thesis http://eprints.utm.my/id/eprint/101779/ http://eprints.utm.my/id/eprint/101779/1/NorernyShuhadaHamdanMSKA2021.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:145654 masters Universiti Teknologi Malaysia, Faculty of Engineering - School of Civil Engineering Faculty of Engineering - School of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Hamdan, Norerny Shuhada
Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure
description Corrosion become the main concern in structure durability which can result in catastrophic failure. Besides, inadequate or wrong selection of water-cement ratio can cause the insufficient readiness of reinforced concrete structure (RC) to the aggressive environment. This issue might arise due to the material cost saving by reducing the material of concrete and at the same time the quality of concrete might be jeopardized during the construction as the consequences of the acts are untraceable in the early stage. The poor quality of concrete in term of penetrability properties can cause the easiness transport of chloride ions into the internal medium of concrete structure. Therefore, the purpose of this research is to highlight the common and frequent problem on the structure deterioration that often related to the chloride-induced corrosion. The pattern and failure mode of concrete and steel were observed using the secondary data collection method from previous study to analyse the intended various factors that contributed to the corrosion of the RC. After all the possible factors that influence the corrosion was determined, the data comparison were done to study their effect on the chloride penetration that led to the occurrence of corrosion. As a result, water-to-cement (w/c) ratio was the main parameter that highlighted as the main cause of the chloride ions penetration that led to the corrosion of reinforced structure at the first place which eventually end up with structure failure. Different parameters were investigated on the degree of corrosion such as the sodium chloride (NaCl) concentration as aggressive agent, the immersion time, and the intended quality concrete casted. The findings show that the lowest chloride penetration depth was 5 mm with w/c ratio of 0.25, and the highest penetration was at the depth of 33 mm with w/c ratio of 0.55 in 3% NaCl solution for 6 months. It can be seen that when w/c ratio increase by 0.1, the chloride penetration depth will increase to approximately 30 to 60%. This results highly prove that the quality of concrete structure plays a significant role in delaying the chloride-induced corrosion. Moreover, these findings can increase the knowledge and awareness of construction practitioner on the importance of designing the adequate quality of concrete structure and ensure the quality was well-maintained to avoid the economic issue arise in future due to corrosion.
format Thesis
qualification_level Master's degree
author Hamdan, Norerny Shuhada
author_facet Hamdan, Norerny Shuhada
author_sort Hamdan, Norerny Shuhada
title Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure
title_short Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure
title_full Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure
title_fullStr Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure
title_full_unstemmed Review on effects of water to cement ratio and chloride penetration in reinforced concrete structure
title_sort review on effects of water to cement ratio and chloride penetration in reinforced concrete structure
granting_institution Universiti Teknologi Malaysia, Faculty of Engineering - School of Civil Engineering
granting_department Faculty of Engineering - School of Civil Engineering
publishDate 2021
url http://eprints.utm.my/id/eprint/101779/1/NorernyShuhadaHamdanMSKA2021.pdf
_version_ 1776100769592770560