High accuracy measurement of gold purity using hydrostatic weighing system

Currently, existing instruments have limitation to determine the purity of gold bar and the method used is not reliable to detect the existence of tungsten in bar. Therefore, a new technique with high accuracy and non-destructive method has been developed to determine the purity of gold bar. In this...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Nor, Mohd. Fazrulhisyam
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/101888/1/MohdFazrulHisyamPhDFS2020.pdf.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.101888
record_format uketd_dc
spelling my-utm-ep.1018882023-07-17T02:41:56Z High accuracy measurement of gold purity using hydrostatic weighing system 2020 Mohd. Nor, Mohd. Fazrulhisyam Q Science (General) Currently, existing instruments have limitation to determine the purity of gold bar and the method used is not reliable to detect the existence of tungsten in bar. Therefore, a new technique with high accuracy and non-destructive method has been developed to determine the purity of gold bar. In this study, three approaches were considered in the construction of hydrostatic weighing system (HWS); establishment of location and environmental condition, establishment of the density measurement of distilled water and establishment the mass measurement of samples. The X-ray fluorescence (XRF) analysis was used to determine the surface purity, while the HWS was used to determine the density of gold bar. The standard sample of gold bar, tungsten bar and fake gold bar were used in this study. Experimental results show that the density of gold bar is proportional to the purity of gold bar. The purity of 99.99% and 99.9% gold has density of 19.293 g/ml and 19.268 g/ml respectively. However, for tungsten, the density of 99.9% tungsten was only 19.206 g/ml with the expanded uncertainty of the density of 0.006 g/ml. Thus, this study demonstrates that the developed HWS is capable to be used to measure the density of gold bar accurately and hence it could detect the presence of tungsten in gold bar. 2020 Thesis http://eprints.utm.my/id/eprint/101888/ http://eprints.utm.my/id/eprint/101888/1/MohdFazrulHisyamPhDFS2020.pdf.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:146062 phd doctoral Universiti Teknologi Malaysia Faculty of Science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic Q Science (General)
spellingShingle Q Science (General)
Mohd. Nor, Mohd. Fazrulhisyam
High accuracy measurement of gold purity using hydrostatic weighing system
description Currently, existing instruments have limitation to determine the purity of gold bar and the method used is not reliable to detect the existence of tungsten in bar. Therefore, a new technique with high accuracy and non-destructive method has been developed to determine the purity of gold bar. In this study, three approaches were considered in the construction of hydrostatic weighing system (HWS); establishment of location and environmental condition, establishment of the density measurement of distilled water and establishment the mass measurement of samples. The X-ray fluorescence (XRF) analysis was used to determine the surface purity, while the HWS was used to determine the density of gold bar. The standard sample of gold bar, tungsten bar and fake gold bar were used in this study. Experimental results show that the density of gold bar is proportional to the purity of gold bar. The purity of 99.99% and 99.9% gold has density of 19.293 g/ml and 19.268 g/ml respectively. However, for tungsten, the density of 99.9% tungsten was only 19.206 g/ml with the expanded uncertainty of the density of 0.006 g/ml. Thus, this study demonstrates that the developed HWS is capable to be used to measure the density of gold bar accurately and hence it could detect the presence of tungsten in gold bar.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Mohd. Nor, Mohd. Fazrulhisyam
author_facet Mohd. Nor, Mohd. Fazrulhisyam
author_sort Mohd. Nor, Mohd. Fazrulhisyam
title High accuracy measurement of gold purity using hydrostatic weighing system
title_short High accuracy measurement of gold purity using hydrostatic weighing system
title_full High accuracy measurement of gold purity using hydrostatic weighing system
title_fullStr High accuracy measurement of gold purity using hydrostatic weighing system
title_full_unstemmed High accuracy measurement of gold purity using hydrostatic weighing system
title_sort high accuracy measurement of gold purity using hydrostatic weighing system
granting_institution Universiti Teknologi Malaysia
granting_department Faculty of Science
publishDate 2020
url http://eprints.utm.my/id/eprint/101888/1/MohdFazrulHisyamPhDFS2020.pdf.pdf
_version_ 1776100795706507264