Improvement of structural stability for multi – storey building by using composite column and cable connection

Two methods for the improvement of structural stability of the building are introduced. These methods ensure that the structural building is safe, reliable and economy with the production of small deflection against seismic loading and any other external effect. The application of composite column a...

Full description

Saved in:
Bibliographic Details
Main Author: Arvin, Yashar
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/11236/1/YasharArvinMFKA2010.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.11236
record_format uketd_dc
spelling my-utm-ep.112362018-05-30T02:35:00Z Improvement of structural stability for multi – storey building by using composite column and cable connection 2010-04 Arvin, Yashar TA Engineering (General). Civil engineering (General) TH Building construction Two methods for the improvement of structural stability of the building are introduced. These methods ensure that the structural building is safe, reliable and economy with the production of small deflection against seismic loading and any other external effect. The application of composite column as flexible material or non-rigid part of the frame structure is introduced and capable to absorb energy comes from the action and reaction of loading. The second approach in this research is by introducing active spring or prestressed cable connections in order to reduce the instability of structural building. The effect of P-delta on two methods stated is studied by performing non-linear analysis by using SAP2000 software on the building and compared the analysis results to conventional structural building with rigid connection. The results from SAP2000 shows that the proposed composite column and structural building with prestressed cable connection provide small deflections under loading compared with the deflection induced by conventional building with rigid connection. This finding proves that the proposed methods for building construction can increase the stability of the structural building. 2010-04 Thesis http://eprints.utm.my/id/eprint/11236/ http://eprints.utm.my/id/eprint/11236/1/YasharArvinMFKA2010.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
TH Building construction
spellingShingle TA Engineering (General)
Civil engineering (General)
TH Building construction
Arvin, Yashar
Improvement of structural stability for multi – storey building by using composite column and cable connection
description Two methods for the improvement of structural stability of the building are introduced. These methods ensure that the structural building is safe, reliable and economy with the production of small deflection against seismic loading and any other external effect. The application of composite column as flexible material or non-rigid part of the frame structure is introduced and capable to absorb energy comes from the action and reaction of loading. The second approach in this research is by introducing active spring or prestressed cable connections in order to reduce the instability of structural building. The effect of P-delta on two methods stated is studied by performing non-linear analysis by using SAP2000 software on the building and compared the analysis results to conventional structural building with rigid connection. The results from SAP2000 shows that the proposed composite column and structural building with prestressed cable connection provide small deflections under loading compared with the deflection induced by conventional building with rigid connection. This finding proves that the proposed methods for building construction can increase the stability of the structural building.
format Thesis
qualification_level Master's degree
author Arvin, Yashar
author_facet Arvin, Yashar
author_sort Arvin, Yashar
title Improvement of structural stability for multi – storey building by using composite column and cable connection
title_short Improvement of structural stability for multi – storey building by using composite column and cable connection
title_full Improvement of structural stability for multi – storey building by using composite column and cable connection
title_fullStr Improvement of structural stability for multi – storey building by using composite column and cable connection
title_full_unstemmed Improvement of structural stability for multi – storey building by using composite column and cable connection
title_sort improvement of structural stability for multi – storey building by using composite column and cable connection
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2010
url http://eprints.utm.my/id/eprint/11236/1/YasharArvinMFKA2010.pdf
_version_ 1747814830346076160