Development of a PC interfaced blood pressure meter (E-BPMS)

Blood pressure is one of the fundamental vital signs, and its measurement is of great importance to medical professionals and the general public alike. Nowadays, there are several types of blood pressure meter available manufactured from various companies. In order to meet the demand on telemedicine...

Full description

Saved in:
Bibliographic Details
Main Author: Mustapha, Baharuddin
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:http://eprints.utm.my/id/eprint/11287/1/BaharuddinMustaphaMFKE2008.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.11287
record_format uketd_dc
spelling my-utm-ep.112872018-07-23T05:37:05Z Development of a PC interfaced blood pressure meter (E-BPMS) 2008-05 Mustapha, Baharuddin TK Electrical engineering. Electronics Nuclear engineering Blood pressure is one of the fundamental vital signs, and its measurement is of great importance to medical professionals and the general public alike. Nowadays, there are several types of blood pressure meter available manufactured from various companies. In order to meet the demand on telemedicine and technology advancement, a new form of blood pressure meter is desirable. This prototype of blood pressure meter is interfaced with a personal computer (PC) which able to simulate the measurement process in real time. The proposed system was named e-BPMS (Electronic Blood Pressure Measurement System) suggests the usage of both hardware and software in determining blood pressure reading. Hardware elements operate on oscillometric principle which gives the results in terms of systolic, diastolic and MAP (Mean Arterial Pressure). Furthermore, these results will be presented and simulated on the software. The e-BPMS interface was developed by using Visual Basic 6.0 language which highlights the user friendly attributes. Moreover, the simulated waveform will evaluate the blood pressure and gives the blood pressure value. This application shows significant improvement on the overall performance and gives reliable results. The framework used to design e-BPMS is easy to understand and it can be extended further to endorse new application area. 2008-05 Thesis http://eprints.utm.my/id/eprint/11287/ http://eprints.utm.my/id/eprint/11287/1/BaharuddinMustaphaMFKE2008.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Mustapha, Baharuddin
Development of a PC interfaced blood pressure meter (E-BPMS)
description Blood pressure is one of the fundamental vital signs, and its measurement is of great importance to medical professionals and the general public alike. Nowadays, there are several types of blood pressure meter available manufactured from various companies. In order to meet the demand on telemedicine and technology advancement, a new form of blood pressure meter is desirable. This prototype of blood pressure meter is interfaced with a personal computer (PC) which able to simulate the measurement process in real time. The proposed system was named e-BPMS (Electronic Blood Pressure Measurement System) suggests the usage of both hardware and software in determining blood pressure reading. Hardware elements operate on oscillometric principle which gives the results in terms of systolic, diastolic and MAP (Mean Arterial Pressure). Furthermore, these results will be presented and simulated on the software. The e-BPMS interface was developed by using Visual Basic 6.0 language which highlights the user friendly attributes. Moreover, the simulated waveform will evaluate the blood pressure and gives the blood pressure value. This application shows significant improvement on the overall performance and gives reliable results. The framework used to design e-BPMS is easy to understand and it can be extended further to endorse new application area.
format Thesis
qualification_level Master's degree
author Mustapha, Baharuddin
author_facet Mustapha, Baharuddin
author_sort Mustapha, Baharuddin
title Development of a PC interfaced blood pressure meter (E-BPMS)
title_short Development of a PC interfaced blood pressure meter (E-BPMS)
title_full Development of a PC interfaced blood pressure meter (E-BPMS)
title_fullStr Development of a PC interfaced blood pressure meter (E-BPMS)
title_full_unstemmed Development of a PC interfaced blood pressure meter (E-BPMS)
title_sort development of a pc interfaced blood pressure meter (e-bpms)
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2008
url http://eprints.utm.my/id/eprint/11287/1/BaharuddinMustaphaMFKE2008.pdf
_version_ 1747814834258313216