Development of novel particle detector with multi pixel photon counter readout

The purpose of this study is to develop a new muon beam monitor for MUon Science Innovative Channel (MUSIC) project at Osaka University. It was a prototype with the dimension of 20x20x1cm3 plastic scintillating counter with wavelength shifting fibers (WLS-Fi) readout to alternate the particle beam t...

Full description

Saved in:
Bibliographic Details
Main Author: Hashim, Izyan Hazwani
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/11324/1/IzyanHazwaniHashimMFS2010.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.11324
record_format uketd_dc
spelling my-utm-ep.113242018-05-27T07:51:22Z Development of novel particle detector with multi pixel photon counter readout 2010-05 Hashim, Izyan Hazwani QC Physics The purpose of this study is to develop a new muon beam monitor for MUon Science Innovative Channel (MUSIC) project at Osaka University. It was a prototype with the dimension of 20x20x1cm3 plastic scintillating counter with wavelength shifting fibers (WLS-Fi) readout to alternate the particle beam to the multi pixel photon counter (MPPC). We are using Strontium-90 as a test source along this research. The data was taken in 10000 events by varying parameters such as number of MPPCs used and the source positions. Raw data will be processed and plotted in a histogram. 12 MPPCs were used to determine light yield by MPPC. A maximum of 10 photons was detected by MPPC nearest to source. It is half of the estimated number of photon which is calculated using formula. Then, we add two photomultiplier tube (PMT) to trigger at opposite direction, we estimated the best position resolution is about 3mm for black sheet condition. As a conclusion, black sheet condition gives best resolution compare to other. 2010-05 Thesis http://eprints.utm.my/id/eprint/11324/ http://eprints.utm.my/id/eprint/11324/1/IzyanHazwaniHashimMFS2010.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Science Faculty of Science [1] Kuno, Y. (2010, 23rd Feb). Introduction to MUSIC. Osaka: RCNP Osaka University. [2] Kuno, Y. (2010). Muon Science. Osaka: RCNP Osaka University. [3] Yoshida, M. (2009, 18th Dec). The MUSIC Project. Osaka: RCNP Osaka University. [4] (2005). Plastic scintilator. Website: www.ggg-tech.co.jp/maker/eljen/list/plastic/ [5] (2005). Scintilation products. Tokyo:Saint Gobain Crystal KK. [6] Aurouet, Bicron & Rudolf, K. B. (1998, 9th April). Wavelength Shifter. [7] Yokoyama, M., Nobuhara, T. et al. (2006, 6th April). Development of Multi Pixel Photon Counters. California: SNIC Symposium. [8] (2006, 31st August). Multi Pixel Photon Counters (MPPC) @ GLDCAL. Website:http://ppwww.phys.sci.kobeu.ac.jp/~kawagoe/gldcal/ind ex.php?MPPC [9] Matsumura, T. (2006, 21st July). Status of the MPPC development. National Defense Academy. [10] Naoki, N. Performance test of Multi Pixel Photon Counters. Kyoto University: Graduate School of Science. [11] (2009, May). Multi Pixel Photon Counter: technical information. Japan: Hamamatsu Photonics. [12] (2001, October). Human Health Fact Sheet: Strontium. Illinois: Argonne
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QC Physics
spellingShingle QC Physics
Hashim, Izyan Hazwani
Development of novel particle detector with multi pixel photon counter readout
description The purpose of this study is to develop a new muon beam monitor for MUon Science Innovative Channel (MUSIC) project at Osaka University. It was a prototype with the dimension of 20x20x1cm3 plastic scintillating counter with wavelength shifting fibers (WLS-Fi) readout to alternate the particle beam to the multi pixel photon counter (MPPC). We are using Strontium-90 as a test source along this research. The data was taken in 10000 events by varying parameters such as number of MPPCs used and the source positions. Raw data will be processed and plotted in a histogram. 12 MPPCs were used to determine light yield by MPPC. A maximum of 10 photons was detected by MPPC nearest to source. It is half of the estimated number of photon which is calculated using formula. Then, we add two photomultiplier tube (PMT) to trigger at opposite direction, we estimated the best position resolution is about 3mm for black sheet condition. As a conclusion, black sheet condition gives best resolution compare to other.
format Thesis
qualification_level Master's degree
author Hashim, Izyan Hazwani
author_facet Hashim, Izyan Hazwani
author_sort Hashim, Izyan Hazwani
title Development of novel particle detector with multi pixel photon counter readout
title_short Development of novel particle detector with multi pixel photon counter readout
title_full Development of novel particle detector with multi pixel photon counter readout
title_fullStr Development of novel particle detector with multi pixel photon counter readout
title_full_unstemmed Development of novel particle detector with multi pixel photon counter readout
title_sort development of novel particle detector with multi pixel photon counter readout
granting_institution Universiti Teknologi Malaysia, Faculty of Science
granting_department Faculty of Science
publishDate 2010
url http://eprints.utm.my/id/eprint/11324/1/IzyanHazwaniHashimMFS2010.pdf
_version_ 1747814839434084352