The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia

Neutron activation analysis (NAA) offers excellent sensitivities that are superior to other analytical techniques in performing identification and quantitative elemental analysis. The technique involves the irradiation of samples and the detection of gamma energies emitted from the isotopes formed f...

Full description

Saved in:
Bibliographic Details
Main Author: Liew, Hwi Fen
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/11347/6/LiewHwiFenMFS2010.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.11347
record_format uketd_dc
spelling my-utm-ep.113472017-09-18T07:21:00Z The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia 2010-01 Liew, Hwi Fen QC Physics Neutron activation analysis (NAA) offers excellent sensitivities that are superior to other analytical techniques in performing identification and quantitative elemental analysis. The technique involves the irradiation of samples and the detection of gamma energies emitted from the isotopes formed from the process of neutron capture. Most NAA were done by comparison method, which is found to have high errors due to the differences in the matrix composition of sample as well as comparator. The purpose of this study is to demonstrate an alternative technique of activation analysis based on absolute gamma ray measurements and the direct calculation of elemental concentrations from reaction rates equation of neutron capture process. The efficiency of the gamma-ray spectrometer as well as the neutron spectrum parameters, thermal and epithermal neutron flux at four characterized irradiation position of 10, 22, 27, and 31 in the rotary rack 1-MW TRIGA reactor at Malaysia Nuclear Agency was determined. The accuracy and precision of this absolute NAA technique were verified by analyzing two certified reference materials, Soil-1 and Soil-7 provided by IAEA. The experimental results for both the materials irradiated at the four characterized irradiation positions were found to be in good agreement with the certified values. The average Z-score for the concentration values were below two signified that the concentration results were accepted for most elements. In conclusion, the proposed technique can be applied for many of future activation analyses with high accuracy without having to rely on the availability of standard samples. 2010-01 Thesis http://eprints.utm.my/id/eprint/11347/ http://eprints.utm.my/id/eprint/11347/6/LiewHwiFenMFS2010.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Science Faculty of Science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QC Physics
spellingShingle QC Physics
Liew, Hwi Fen
The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia
description Neutron activation analysis (NAA) offers excellent sensitivities that are superior to other analytical techniques in performing identification and quantitative elemental analysis. The technique involves the irradiation of samples and the detection of gamma energies emitted from the isotopes formed from the process of neutron capture. Most NAA were done by comparison method, which is found to have high errors due to the differences in the matrix composition of sample as well as comparator. The purpose of this study is to demonstrate an alternative technique of activation analysis based on absolute gamma ray measurements and the direct calculation of elemental concentrations from reaction rates equation of neutron capture process. The efficiency of the gamma-ray spectrometer as well as the neutron spectrum parameters, thermal and epithermal neutron flux at four characterized irradiation position of 10, 22, 27, and 31 in the rotary rack 1-MW TRIGA reactor at Malaysia Nuclear Agency was determined. The accuracy and precision of this absolute NAA technique were verified by analyzing two certified reference materials, Soil-1 and Soil-7 provided by IAEA. The experimental results for both the materials irradiated at the four characterized irradiation positions were found to be in good agreement with the certified values. The average Z-score for the concentration values were below two signified that the concentration results were accepted for most elements. In conclusion, the proposed technique can be applied for many of future activation analyses with high accuracy without having to rely on the availability of standard samples.
format Thesis
qualification_level Master's degree
author Liew, Hwi Fen
author_facet Liew, Hwi Fen
author_sort Liew, Hwi Fen
title The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia
title_short The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia
title_full The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia
title_fullStr The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia
title_full_unstemmed The absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, Malaysia
title_sort absolute method of neutron activation analysis using triga neutron reactor, nuclear agency, malaysia
granting_institution Universiti Teknologi Malaysia, Faculty of Science
granting_department Faculty of Science
publishDate 2010
url http://eprints.utm.my/id/eprint/11347/6/LiewHwiFenMFS2010.pdf
_version_ 1747814841389678592