Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat

Close range photogrammetry is an easy and swift method to obtain the dimensions of objects from images captured by cameras. The types of cameras used in photogrammetry can be classified into two, namely, metric and non-metric. The difference between these two types of cameras is the stability of the...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Abdul Rahman, Fazli
التنسيق: أطروحة
اللغة:English
منشور في: 2006
الموضوعات:
الوصول للمادة أونلاين:http://eprints.utm.my/id/eprint/2129/1/FazliAbdulRahmanMFGHT2006.pdf
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
id my-utm-ep.2129
record_format uketd_dc
spelling my-utm-ep.21292018-06-13T07:05:30Z Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat 2006-05 Abdul Rahman, Fazli HD Industries. Land use. Labor TR Photography Close range photogrammetry is an easy and swift method to obtain the dimensions of objects from images captured by cameras. The types of cameras used in photogrammetry can be classified into two, namely, metric and non-metric. The difference between these two types of cameras is the stability of their inner orientation parameters. Metric cameras have very stable inner orientation parameters compared to non-metric cameras. This research employed the use of non-metric cameras to analyse the design of a calibration frame in order to determine their inner orientation parameters. The designed of the frame is based on the optimum number of points and target sizes. In total, three camera calibration frames have been used in this study. The inner orientation parameters of a kodak dc290 and canon ixus s400 were determined. The software used to perform the calibration was australis 5.0. Results have shown that an optimum number of points required to produce accuracy 1:15,000 is 53 with 3 mm target sizes. Validation of the results was done using independent systems and the difference, 0.05mm. It is therefore can be concluded that the calibration frame designed in this study is suitable to be used for calibrating non-metric cameras with high accuracy 2006-05 Thesis http://eprints.utm.my/id/eprint/2129/ http://eprints.utm.my/id/eprint/2129/1/FazliAbdulRahmanMFGHT2006.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Geoinformation Science and Engineering; Department of Geomatic Engineering Faculty of Geoinformation Science and Engineering; Department of Geomatic Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic HD Industries
Land use
Labor
TR Photography
spellingShingle HD Industries
Land use
Labor
TR Photography
Abdul Rahman, Fazli
Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat
description Close range photogrammetry is an easy and swift method to obtain the dimensions of objects from images captured by cameras. The types of cameras used in photogrammetry can be classified into two, namely, metric and non-metric. The difference between these two types of cameras is the stability of their inner orientation parameters. Metric cameras have very stable inner orientation parameters compared to non-metric cameras. This research employed the use of non-metric cameras to analyse the design of a calibration frame in order to determine their inner orientation parameters. The designed of the frame is based on the optimum number of points and target sizes. In total, three camera calibration frames have been used in this study. The inner orientation parameters of a kodak dc290 and canon ixus s400 were determined. The software used to perform the calibration was australis 5.0. Results have shown that an optimum number of points required to produce accuracy 1:15,000 is 53 with 3 mm target sizes. Validation of the results was done using independent systems and the difference, 0.05mm. It is therefore can be concluded that the calibration frame designed in this study is suitable to be used for calibrating non-metric cameras with high accuracy
format Thesis
qualification_level Master's degree
author Abdul Rahman, Fazli
author_facet Abdul Rahman, Fazli
author_sort Abdul Rahman, Fazli
title Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat
title_short Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat
title_full Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat
title_fullStr Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat
title_full_unstemmed Analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat
title_sort analisa terhadap rekabentuk bingkai kalibrasi bagi kamera digital untuk fotogrametri jarak dekat
granting_institution Universiti Teknologi Malaysia, Faculty of Geoinformation Science and Engineering; Department of Geomatic Engineering
granting_department Faculty of Geoinformation Science and Engineering; Department of Geomatic Engineering
publishDate 2006
url http://eprints.utm.my/id/eprint/2129/1/FazliAbdulRahmanMFGHT2006.pdf
_version_ 1747814398971346944