Field testing of MOSAIMS@

Surge arrester is an important protection device installed mostly at the power transmission substation. It is used to safely channel through the overvoltage surge due to the lightning or switching effect to the ground and thus protecting the other vital power equipment at the substation. Ageing or d...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Yousof, Mohd. Fairouz
Format: Thesis
Published: 2010
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.26744
record_format uketd_dc
spelling my-utm-ep.267442017-08-22T01:46:21Z Field testing of MOSAIMS@ 2010 Mohd. Yousof, Mohd. Fairouz TK Electrical engineering. Electronics Nuclear engineering Surge arrester is an important protection device installed mostly at the power transmission substation. It is used to safely channel through the overvoltage surge due to the lightning or switching effect to the ground and thus protecting the other vital power equipment at the substation. Ageing or degradation of the arrester is an important aspect to be concern with because the arrester may be due for replacement. Predictive maintenance should be conducted from time to time in order to monitor the degradation of the arrester and predict when to change the arrester before it fails. The leakage current that flows through the arrester during the normal condition can be measured easily using current probe, and its third harmonic resistive leakage current is directly related to the ageing of the arrester. Various methods were used to measure the third harmonic leakage current, among the latest is Modified Shifted Current Method (MSCM). This method has been applied to a newly developed portable device which is called the Metal Oxide Surge Arrester Intelligent Monitoring SYSTEM (MOSAIMS). MOSAIMS which is developed in the Institute of High Voltage and High Current (IVAT) has been through testing at the high voltage laboratory before and due to the lack of actual measurements at the power transmission substations, the performance of the MOSAIMS is still yet to be concluded. This project aims to thoroughly test the MOSAIMS especially to determine its accuracy on measuring the third harmonic resistive leakage current. The measurements from the MOSAIMS will be compared with the measurements using SCAR-10, a device which is used by the local power utility company. Finally, the report on the measurement accuracy of MOSAIMS and the possible future works in improving the MOSAIMS included. 2010 Thesis http://eprints.utm.my/id/eprint/26744/ http://libraryopac.utm.my/client/en_AU/main/search/results?qu=Field+testing+of+MOSAIMS%40&te= masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Mohd. Yousof, Mohd. Fairouz
Field testing of MOSAIMS@
description Surge arrester is an important protection device installed mostly at the power transmission substation. It is used to safely channel through the overvoltage surge due to the lightning or switching effect to the ground and thus protecting the other vital power equipment at the substation. Ageing or degradation of the arrester is an important aspect to be concern with because the arrester may be due for replacement. Predictive maintenance should be conducted from time to time in order to monitor the degradation of the arrester and predict when to change the arrester before it fails. The leakage current that flows through the arrester during the normal condition can be measured easily using current probe, and its third harmonic resistive leakage current is directly related to the ageing of the arrester. Various methods were used to measure the third harmonic leakage current, among the latest is Modified Shifted Current Method (MSCM). This method has been applied to a newly developed portable device which is called the Metal Oxide Surge Arrester Intelligent Monitoring SYSTEM (MOSAIMS). MOSAIMS which is developed in the Institute of High Voltage and High Current (IVAT) has been through testing at the high voltage laboratory before and due to the lack of actual measurements at the power transmission substations, the performance of the MOSAIMS is still yet to be concluded. This project aims to thoroughly test the MOSAIMS especially to determine its accuracy on measuring the third harmonic resistive leakage current. The measurements from the MOSAIMS will be compared with the measurements using SCAR-10, a device which is used by the local power utility company. Finally, the report on the measurement accuracy of MOSAIMS and the possible future works in improving the MOSAIMS included.
format Thesis
qualification_level Master's degree
author Mohd. Yousof, Mohd. Fairouz
author_facet Mohd. Yousof, Mohd. Fairouz
author_sort Mohd. Yousof, Mohd. Fairouz
title Field testing of MOSAIMS@
title_short Field testing of MOSAIMS@
title_full Field testing of MOSAIMS@
title_fullStr Field testing of MOSAIMS@
title_full_unstemmed Field testing of MOSAIMS@
title_sort field testing of mosaims@
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2010
_version_ 1747815500314836992