Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water

In this work, a sample preparation method based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for the extraction of polycyclic aromatic hydrocarbons (PAHs), namely phenanthrene and fluoranthene from water sample. In this m...

Full description

Saved in:
Bibliographic Details
Main Author: Sharef A., Sarra Younes
Format: Thesis
Language:English
Published: 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/28697/1/SarraYounesSharefAMFS2011.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.28697
record_format uketd_dc
spelling my-utm-ep.286972018-05-27T06:39:00Z Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water 2011 Sharef A., Sarra Younes Q Science (General) In this work, a sample preparation method based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for the extraction of polycyclic aromatic hydrocarbons (PAHs), namely phenanthrene and fluoranthene from water sample. In this method, a mixture of carbon tetrachloride, CCl4 (extraction solvent) and acetone (disperser solvent) was injected using a syringe into 5 mL water sample to form emulsion where the PAHs were extracted into the fine droplets of extraction solvent. The solution was then centrifuged for 3 min at 3000 rpm and the fine droplets were sedimented at the bottom of centrifuge tube. Sedimented phase (1 ?L) was injected into the GC-MS for separation and determination of PAHs. The effects of various extraction parameters namely extraction solvent type, disperser solvent type, volume of extraction solvent, and volume of disperser solvent were investigated. The optimized conditions for DLLME of selected PAHs were carbon tetrachloride as extraction solvent, 60 ?L of extraction solvent (CCl4), acetone as disperser solvent and 1 mL of disperser solvent (acetone). The correlation coefficient (r2) of the calibration curve for phenanthrene and fluoranthene were 0.9993 and 0.9973, respectively. The limits of detection (LODs) obtained for phenanthrene and fluoranthene were 0.0008 ?g/mL and 0.0006 ?g/mL, respectively. The proposed method proved to be reproducible with relative standard deviations (RSDs) of 10.69 % and 9.72 % for phenanthrene and fluoranthene, respectively. The analyte recoveries were 100.5 – 107.8 %. The concentration of was 0.02-0.15 ?g/mL. It was found that phenanthrene and fluoranthene were present in lake water sample at concentrations of 3.47×10-3 and 2.69×10-3 ?g/mL. The DLLME method combined with GC-MS proved to be an efficient method and was applied successfully for the determination of PAHs from water sample 2011 Thesis http://eprints.utm.my/id/eprint/28697/ http://eprints.utm.my/id/eprint/28697/1/SarraYounesSharefAMFS2011.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Science Universiti Teknologi Malaysia, Faculty of Science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic Q Science (General)
spellingShingle Q Science (General)
Sharef A., Sarra Younes
Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water
description In this work, a sample preparation method based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for the extraction of polycyclic aromatic hydrocarbons (PAHs), namely phenanthrene and fluoranthene from water sample. In this method, a mixture of carbon tetrachloride, CCl4 (extraction solvent) and acetone (disperser solvent) was injected using a syringe into 5 mL water sample to form emulsion where the PAHs were extracted into the fine droplets of extraction solvent. The solution was then centrifuged for 3 min at 3000 rpm and the fine droplets were sedimented at the bottom of centrifuge tube. Sedimented phase (1 ?L) was injected into the GC-MS for separation and determination of PAHs. The effects of various extraction parameters namely extraction solvent type, disperser solvent type, volume of extraction solvent, and volume of disperser solvent were investigated. The optimized conditions for DLLME of selected PAHs were carbon tetrachloride as extraction solvent, 60 ?L of extraction solvent (CCl4), acetone as disperser solvent and 1 mL of disperser solvent (acetone). The correlation coefficient (r2) of the calibration curve for phenanthrene and fluoranthene were 0.9993 and 0.9973, respectively. The limits of detection (LODs) obtained for phenanthrene and fluoranthene were 0.0008 ?g/mL and 0.0006 ?g/mL, respectively. The proposed method proved to be reproducible with relative standard deviations (RSDs) of 10.69 % and 9.72 % for phenanthrene and fluoranthene, respectively. The analyte recoveries were 100.5 – 107.8 %. The concentration of was 0.02-0.15 ?g/mL. It was found that phenanthrene and fluoranthene were present in lake water sample at concentrations of 3.47×10-3 and 2.69×10-3 ?g/mL. The DLLME method combined with GC-MS proved to be an efficient method and was applied successfully for the determination of PAHs from water sample
format Thesis
qualification_level Master's degree
author Sharef A., Sarra Younes
author_facet Sharef A., Sarra Younes
author_sort Sharef A., Sarra Younes
title Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water
title_short Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water
title_full Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water
title_fullStr Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water
title_full_unstemmed Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water
title_sort dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water
granting_institution Universiti Teknologi Malaysia, Faculty of Science
granting_department Universiti Teknologi Malaysia, Faculty of Science
publishDate 2011
url http://eprints.utm.my/id/eprint/28697/1/SarraYounesSharefAMFS2011.pdf
_version_ 1747815681890451456