SVM based hysteresis current controller for a three phase active power filter

A space vector modulation (SVM) based hysteresis current controller (HCC) technique for a three phase shunt active power filter is proposed. The proposed SVM based HCC is implemented in a closed loop control system. The reference input to the control system is the reference compensating harmonic cur...

Full description

Saved in:
Bibliographic Details
Main Author: Leow, Pei Ling
Format: Thesis
Language:English
Published: 2004
Subjects:
Online Access:http://eprints.utm.my/id/eprint/3189/1/LeowPeiLingMFKE2004.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.3189
record_format uketd_dc
spelling my-utm-ep.31892018-06-25T00:48:16Z SVM based hysteresis current controller for a three phase active power filter 2004-10 Leow, Pei Ling TK Electrical engineering. Electronics Nuclear engineering A space vector modulation (SVM) based hysteresis current controller (HCC) technique for a three phase shunt active power filter is proposed. The proposed SVM based HCC is implemented in a closed loop control system. The reference input to the control system is the reference compensating harmonic current. The reference compensating harmonic current is obtained from the harmonic extraction tool or called as the harmonics isolator. The harmonics extraction is based on the instantaneous active and reactive power theorem in time domain to calculate the reactive power compensation in the power system. The error current is the difference between the reference and the actual compensating harmonic current from the power compensation. Three error currents are obtained and compared by using the hysteresis tolerance band comparators to obtain the information about the region and voltage vector. The switching control algorithms of the proposed SVM based HCC manages to generate appropriate switching gates to the active power filter. The active power filter generates the actual compensating harmonic current based on the switching gates provided by the controller. The actual compensating harmonic current is generated based on the reference compensating harmonic current. The actual compensating harmonic current is then injected back into the line to cancel the harmonic components in the distorted line. By implementing this control strategy, the active power filter (APF) manages to generate better compensated harmonics currents to the line. The proposed active power filter is able to improve about 67% of the total harmonic distortion (THD) for the distorted line current caused by an uncontrolled rectifier as the nonlinear load 2004-10 Thesis http://eprints.utm.my/id/eprint/3189/ http://eprints.utm.my/id/eprint/3189/1/LeowPeiLingMFKE2004.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Leow, Pei Ling
SVM based hysteresis current controller for a three phase active power filter
description A space vector modulation (SVM) based hysteresis current controller (HCC) technique for a three phase shunt active power filter is proposed. The proposed SVM based HCC is implemented in a closed loop control system. The reference input to the control system is the reference compensating harmonic current. The reference compensating harmonic current is obtained from the harmonic extraction tool or called as the harmonics isolator. The harmonics extraction is based on the instantaneous active and reactive power theorem in time domain to calculate the reactive power compensation in the power system. The error current is the difference between the reference and the actual compensating harmonic current from the power compensation. Three error currents are obtained and compared by using the hysteresis tolerance band comparators to obtain the information about the region and voltage vector. The switching control algorithms of the proposed SVM based HCC manages to generate appropriate switching gates to the active power filter. The active power filter generates the actual compensating harmonic current based on the switching gates provided by the controller. The actual compensating harmonic current is generated based on the reference compensating harmonic current. The actual compensating harmonic current is then injected back into the line to cancel the harmonic components in the distorted line. By implementing this control strategy, the active power filter (APF) manages to generate better compensated harmonics currents to the line. The proposed active power filter is able to improve about 67% of the total harmonic distortion (THD) for the distorted line current caused by an uncontrolled rectifier as the nonlinear load
format Thesis
qualification_level Master's degree
author Leow, Pei Ling
author_facet Leow, Pei Ling
author_sort Leow, Pei Ling
title SVM based hysteresis current controller for a three phase active power filter
title_short SVM based hysteresis current controller for a three phase active power filter
title_full SVM based hysteresis current controller for a three phase active power filter
title_fullStr SVM based hysteresis current controller for a three phase active power filter
title_full_unstemmed SVM based hysteresis current controller for a three phase active power filter
title_sort svm based hysteresis current controller for a three phase active power filter
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2004
url http://eprints.utm.my/id/eprint/3189/1/LeowPeiLingMFKE2004.pdf
_version_ 1747814440936407040