Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters

By the rapid of urban growth, it is impossible to accommodate the number and size of feeder required for distribution using the overhead line system approach. As an alternative the underground cables becomes more increasingly necessary to replace some of the overhead line for power transmission and...

Full description

Saved in:
Bibliographic Details
Main Author: Ponniran, Asmarashid
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/id/eprint/3567/1/AsmarashidPonniranMFKE2005.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.3567
record_format uketd_dc
spelling my-utm-ep.35672018-06-25T01:04:51Z Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters 2005-03 Ponniran, Asmarashid TK Electrical engineering. Electronics Nuclear engineering By the rapid of urban growth, it is impossible to accommodate the number and size of feeder required for distribution using the overhead line system approach. As an alternative the underground cables becomes more increasingly necessary to replace some of the overhead line for power transmission and distribution. Because of that reason, underground XLPE cables are the most popular for the underground systems. Performance of underground cables in service is being critical because of ageing mechanisms influences. There are many suitable techniques can be used to evaluate performance of aged and unaged underground cables. One of the techniques is based on tan delta and capacitance parameters of underground cables. This study only focuses on underground XLPE cables, which are voltage rated at11kV and 22kV for 1-core and 3-cores types. By using Tettex Instruments – Schering Bridge Model 2816, tan delta and capacitance data of XLPE underground cables are obtained. Tan delta and capacitance measurements were performed at ambient temperature (26.6oC) and at power frequency (50 Hz). From these analyses, show that tan delta values will be increased proportional with aging time of cables in service. Aging mechanisms are contributes these deteriorations of cables in service and consequently values of tan delta are increased with aging time of cable. Meanwhile, form capacitance analysis, the values of capacitance will be increased when contaminants, protrusions and voids are affected cables insulation and when moisture enters inside underground cable systems 2005-03 Thesis http://eprints.utm.my/id/eprint/3567/ http://eprints.utm.my/id/eprint/3567/1/AsmarashidPonniranMFKE2005.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Ponniran, Asmarashid
Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters
description By the rapid of urban growth, it is impossible to accommodate the number and size of feeder required for distribution using the overhead line system approach. As an alternative the underground cables becomes more increasingly necessary to replace some of the overhead line for power transmission and distribution. Because of that reason, underground XLPE cables are the most popular for the underground systems. Performance of underground cables in service is being critical because of ageing mechanisms influences. There are many suitable techniques can be used to evaluate performance of aged and unaged underground cables. One of the techniques is based on tan delta and capacitance parameters of underground cables. This study only focuses on underground XLPE cables, which are voltage rated at11kV and 22kV for 1-core and 3-cores types. By using Tettex Instruments – Schering Bridge Model 2816, tan delta and capacitance data of XLPE underground cables are obtained. Tan delta and capacitance measurements were performed at ambient temperature (26.6oC) and at power frequency (50 Hz). From these analyses, show that tan delta values will be increased proportional with aging time of cables in service. Aging mechanisms are contributes these deteriorations of cables in service and consequently values of tan delta are increased with aging time of cable. Meanwhile, form capacitance analysis, the values of capacitance will be increased when contaminants, protrusions and voids are affected cables insulation and when moisture enters inside underground cable systems
format Thesis
qualification_level Master's degree
author Ponniran, Asmarashid
author_facet Ponniran, Asmarashid
author_sort Ponniran, Asmarashid
title Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters
title_short Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters
title_full Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters
title_fullStr Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters
title_full_unstemmed Study on the performance of underground XLPE cables in service based on tan delta and capacitance parameters
title_sort study on the performance of underground xlpe cables in service based on tan delta and capacitance parameters
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2005
url http://eprints.utm.my/id/eprint/3567/1/AsmarashidPonniranMFKE2005.pdf
_version_ 1747814454385442816