Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system

The connection between beam and column affects directly the integrity of the building structure, In precast reinforced concrete Industrialised Building Systems (IBS), complexity often occurred in the implementation of a new type of beam-to-column connection. "This is due to the new IBS arrangem...

Full description

Saved in:
Bibliographic Details
Main Author: Moghadasi, Mostafa
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/39037/5/MostafaMoghadasiPFKA2013.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.39037
record_format uketd_dc
spelling my-utm-ep.390372017-07-06T01:51:40Z Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system 2013-07 Moghadasi, Mostafa TA Engineering (General). Civil engineering (General) The connection between beam and column affects directly the integrity of the building structure, In precast reinforced concrete Industrialised Building Systems (IBS), complexity often occurred in the implementation of a new type of beam-to-column connection. "This is due to the new IBS arrangement and the consequent new interaction between the jointed elements of beam and column, In this study, an innovative new type of semi-rigid beam-to-column connection, called SMART IBS consisting of beam to column steel connectors and reinforced concrete elements cast together were detailed out. Four full scale experimental tests were conducted to achieve the real behaviour of the connection in H-shape and Cruciform sub-frames. The tests were supplemented with conventional monolithic models representing the moment resisting connection for comparison of structural specifications. Moreover, for obtaining more comprehensive behaviour, nonlinear finite element analysis (NLFEA) using ABAQUS software was conducted. Furthermore, the whole behaviour of IBS using this new connection was researched through 3D linear analysis to include gravitational and seismic time-history loads using SAP 2000 software, The response of the connection was investigated through the study of the ultimate loading capacity, ductility ratio, load-displacement, moment-rotation, modes of failure and crack patterns. The results of this research confirmed that the new SMART IBS beam-to-column connection was a semi-rigid connection with extra beneficial ductility in comparison with conventional reinforced concrete connection. The ultimate strength of the SMART IBS beam-to-column connection was equal to the conventional model. Furthermore, the results of NLFEA were matched up to 90"/0 with experimental tests. In terms of seismic performance, a three dimensional building of SMART IBS seismic performance was better than the conventional reinforced concrete frames. 2013-07 Thesis http://eprints.utm.my/id/eprint/39037/ http://eprints.utm.my/id/eprint/39037/5/MostafaMoghadasiPFKA2013.pdf application/pdf en public phd doctoral Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Moghadasi, Mostafa
Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system
description The connection between beam and column affects directly the integrity of the building structure, In precast reinforced concrete Industrialised Building Systems (IBS), complexity often occurred in the implementation of a new type of beam-to-column connection. "This is due to the new IBS arrangement and the consequent new interaction between the jointed elements of beam and column, In this study, an innovative new type of semi-rigid beam-to-column connection, called SMART IBS consisting of beam to column steel connectors and reinforced concrete elements cast together were detailed out. Four full scale experimental tests were conducted to achieve the real behaviour of the connection in H-shape and Cruciform sub-frames. The tests were supplemented with conventional monolithic models representing the moment resisting connection for comparison of structural specifications. Moreover, for obtaining more comprehensive behaviour, nonlinear finite element analysis (NLFEA) using ABAQUS software was conducted. Furthermore, the whole behaviour of IBS using this new connection was researched through 3D linear analysis to include gravitational and seismic time-history loads using SAP 2000 software, The response of the connection was investigated through the study of the ultimate loading capacity, ductility ratio, load-displacement, moment-rotation, modes of failure and crack patterns. The results of this research confirmed that the new SMART IBS beam-to-column connection was a semi-rigid connection with extra beneficial ductility in comparison with conventional reinforced concrete connection. The ultimate strength of the SMART IBS beam-to-column connection was equal to the conventional model. Furthermore, the results of NLFEA were matched up to 90"/0 with experimental tests. In terms of seismic performance, a three dimensional building of SMART IBS seismic performance was better than the conventional reinforced concrete frames.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Moghadasi, Mostafa
author_facet Moghadasi, Mostafa
author_sort Moghadasi, Mostafa
title Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system
title_short Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system
title_full Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system
title_fullStr Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system
title_full_unstemmed Nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system
title_sort nonlinear behaviour of beam-to-column connection in reinforced concrete industrialised building system
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2013
url http://eprints.utm.my/id/eprint/39037/5/MostafaMoghadasiPFKA2013.pdf
_version_ 1747816540474966016