Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads

This project is containing of simulation on sectioned Bovine Trabecular Bone. The Bone was extracted from fresh bovine bone with interested section dimension for about 2 × 2 × 3.5 mm. After scanned process through µCT scanner, the bone was constructed via Mimics software. With preferred size of elem...

Full description

Saved in:
Bibliographic Details
Main Author: Arsat, Zainal Abidin
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/41920/1/ZainalAbidinArsatMFKM2013.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.41920
record_format uketd_dc
spelling my-utm-ep.419202017-09-12T06:31:27Z Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads 2013-01 Arsat, Zainal Abidin QP Physiology This project is containing of simulation on sectioned Bovine Trabecular Bone. The Bone was extracted from fresh bovine bone with interested section dimension for about 2 × 2 × 3.5 mm. After scanned process through µCT scanner, the bone was constructed via Mimics software. With preferred size of elements and consumed time per simulation, 774,996 elements were selected meshing number to use. Combination of 3 axes loads for both physiological movement specific to normal walking loads and downstairs loads, those presented one minute trends cycle completed both cycle as reliable applying loads in the consequent Trabecular Bone model. Simulation was conducted by fixed the model at the bottom and applying gait loads at the top, revealed most deflection of Trabecular Bone were occurred while down stairs activities. The most stress entire simulation also weighed to down stairs activities. From that, it composes young modulus for normal walking is 14.8Gpa. In the other hand, downstairs activities complies 14.9Gpa. Deviation on the experimental data of compressive test, could be translate on different of density model, besides, by doing only compressive stress could not represent on physiological loads on actual real situation. 2013-01 Thesis http://eprints.utm.my/id/eprint/41920/ http://eprints.utm.my/id/eprint/41920/1/ZainalAbidinArsatMFKM2013.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Mechanical Engineering Faculty of Mechanical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QP Physiology
spellingShingle QP Physiology
Arsat, Zainal Abidin
Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads
description This project is containing of simulation on sectioned Bovine Trabecular Bone. The Bone was extracted from fresh bovine bone with interested section dimension for about 2 × 2 × 3.5 mm. After scanned process through µCT scanner, the bone was constructed via Mimics software. With preferred size of elements and consumed time per simulation, 774,996 elements were selected meshing number to use. Combination of 3 axes loads for both physiological movement specific to normal walking loads and downstairs loads, those presented one minute trends cycle completed both cycle as reliable applying loads in the consequent Trabecular Bone model. Simulation was conducted by fixed the model at the bottom and applying gait loads at the top, revealed most deflection of Trabecular Bone were occurred while down stairs activities. The most stress entire simulation also weighed to down stairs activities. From that, it composes young modulus for normal walking is 14.8Gpa. In the other hand, downstairs activities complies 14.9Gpa. Deviation on the experimental data of compressive test, could be translate on different of density model, besides, by doing only compressive stress could not represent on physiological loads on actual real situation.
format Thesis
qualification_level Master's degree
author Arsat, Zainal Abidin
author_facet Arsat, Zainal Abidin
author_sort Arsat, Zainal Abidin
title Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads
title_short Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads
title_full Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads
title_fullStr Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads
title_full_unstemmed Numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads
title_sort numerical analysis of bovine trabecular bone by using physiological loads specific to normal walking loads and down stairs loads
granting_institution Universiti Teknologi Malaysia, Faculty of Mechanical Engineering
granting_department Faculty of Mechanical Engineering
publishDate 2013
url http://eprints.utm.my/id/eprint/41920/1/ZainalAbidinArsatMFKM2013.pdf
_version_ 1747816649185034240