Dynamic response prediction of steel frame structure considering semi-rigid connection by applying damper
In design stage, the conventional steel buildings are commonly using the methods of pinned design which means that the behavior of the connection is fully on the basis of pin and rigid design which means that the behavior of the connection is completely rigid. In contrast, the real behavior of joint...