Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building

Energy efficiency is the most important for reducing the operating costs and manages the electricity efficiently and indirectly will contributes the green building indices. This mean that's the significant cost savings is achieved with energy efficiency improvements, and due to continually impr...

Full description

Saved in:
Bibliographic Details
Main Author: Arshad, Arshnah Irni Yusnita
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/43974/5/ArshnahIrniYusnitaArshadMFKE2014.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.43974
record_format uketd_dc
spelling my-utm-ep.439742017-09-07T01:37:23Z Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building 2014-01 Arshad, Arshnah Irni Yusnita TK Electrical engineering. Electronics Nuclear engineering Energy efficiency is the most important for reducing the operating costs and manages the electricity efficiently and indirectly will contributes the green building indices. This mean that's the significant cost savings is achieved with energy efficiency improvements, and due to continually improving equipment, lighting and air conditioning system usually provides the highest return on investment of major upgrade. Therefore, the methodology proposed are to analyses the potential of energy saving, life cycle cost and payback period of the retrofitted lighting system and mechanical ventilation system. The research done explores the effectiveness of the proposed idea through case study conducted for an existing commercial building located in Kota Bharu Kelantan. This building belongs to the federal government and functions as a Fire and Rescue Department district headquarters for the state of Kelantan. Currently, the building is using T8 Magnetic ballast type for the lighting system and normal exhaust fan for fresh air system of air conditioning and mechanical ventilation system due to budgetary cost constraint during design and construction stage. The new alternative proposed method was done by replacing the building lighting system to T8 electronic, TS and LED lamp and pre cooled of VRF System as fresh air supply to the air conditioned area. The software environment has been implemented by using Relux Suite and Diakin HKGSG as simulator in order to perform the design calculation for illumination level and cooling load. The final finding based on the output simulation results show that by implementing both the LED lighting and pre-cooled system can give the highest amount of energy saving and reasonable payback period even with the high cost of installation for the initial stage. 2014-01 Thesis http://eprints.utm.my/id/eprint/43974/ http://eprints.utm.my/id/eprint/43974/5/ArshnahIrniYusnitaArshadMFKE2014.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Arshad, Arshnah Irni Yusnita
Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building
description Energy efficiency is the most important for reducing the operating costs and manages the electricity efficiently and indirectly will contributes the green building indices. This mean that's the significant cost savings is achieved with energy efficiency improvements, and due to continually improving equipment, lighting and air conditioning system usually provides the highest return on investment of major upgrade. Therefore, the methodology proposed are to analyses the potential of energy saving, life cycle cost and payback period of the retrofitted lighting system and mechanical ventilation system. The research done explores the effectiveness of the proposed idea through case study conducted for an existing commercial building located in Kota Bharu Kelantan. This building belongs to the federal government and functions as a Fire and Rescue Department district headquarters for the state of Kelantan. Currently, the building is using T8 Magnetic ballast type for the lighting system and normal exhaust fan for fresh air system of air conditioning and mechanical ventilation system due to budgetary cost constraint during design and construction stage. The new alternative proposed method was done by replacing the building lighting system to T8 electronic, TS and LED lamp and pre cooled of VRF System as fresh air supply to the air conditioned area. The software environment has been implemented by using Relux Suite and Diakin HKGSG as simulator in order to perform the design calculation for illumination level and cooling load. The final finding based on the output simulation results show that by implementing both the LED lighting and pre-cooled system can give the highest amount of energy saving and reasonable payback period even with the high cost of installation for the initial stage.
format Thesis
qualification_level Master's degree
author Arshad, Arshnah Irni Yusnita
author_facet Arshad, Arshnah Irni Yusnita
author_sort Arshad, Arshnah Irni Yusnita
title Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building
title_short Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building
title_full Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building
title_fullStr Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building
title_full_unstemmed Optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building
title_sort optimization design of the lighting and variable refrigerant flow system for the improvement of energy efficiency in existing building
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2014
url http://eprints.utm.my/id/eprint/43974/5/ArshnahIrniYusnitaArshadMFKE2014.pdf
_version_ 1747817126613221376