Effect of photon irradiation on the thermoluminescence response of optical fibres

Studies on silica glass (SiO2) optical fibre as thermoluminescent materials for medical radiation dosimetry have been conducted by several research groups. This study focuses on the thermoluminescence (TL) response, linearity, sensitivity, dose response, fading, reproducibility and minimum detectabl...

Full description

Saved in:
Bibliographic Details
Main Author: Mohamad Sharif, Nurul Ain
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/47937/25/NurulAinMohamadMFS2013.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.47937
record_format uketd_dc
spelling my-utm-ep.479372017-06-20T08:38:52Z Effect of photon irradiation on the thermoluminescence response of optical fibres 2013-12 Mohamad Sharif, Nurul Ain QC Physics Studies on silica glass (SiO2) optical fibre as thermoluminescent materials for medical radiation dosimetry have been conducted by several research groups. This study focuses on the thermoluminescence (TL) response, linearity, sensitivity, dose response, fading, reproducibility and minimum detectable dose of 12 optical fibres sample namely Ge (A) Batch 1, 2 and 3, Ge (B), Multi Photonic Crystal Fibre (MPCF, 220 µm), Multi Photonic Crystal Fibre (MPCF, 2 mm), photonic crystal fibres (PCF), Dummy Flat Fibre (DFF), Flat fiber, Photosensitive Flat Fibre (PFF), Erbium (Er) and Aluminium/ Thulium (Al + Tm) doped optical fibre. A comparison was performed with TLD-100 (chips) to obtain the best TL response among the samples. Irradiation were performed with 6 and 10 MV photons covering the dose range of 1 Gy to 4 Gy by using linear accelerator machine Elekta SynergyTM at Pantai Hospital, Kuala Lumpur and Varian Model 2100C linear accelerator at University Malaya Medical Centre (UMMC). The comparisons of TL response with different model linear accelerators involved in this research were also performed. The results show that the highest sensitivity was obtained by using TLD-100, followed by PFF, Flat, Ge (A) Batch 1, MPCF (2 mm), Ge (A) Batch 3, Ge (A) Batch 2, DFF, Al+Tm, Ge (B), Er, MPCF (220 µm) and PCF. The fading of 5 optical fibres Ge (A) Batch 1, PFF, Er, Flat Fibre and PCF were determined and the loss of the TL signal for these TL materials were 10%, 29%, 30%, 30% and 43%, respectively. The dopant concentrations of Ge (A) Batch 1, Ge (B) and Er were found to be in the range of 0.03-0.72 mol % while the Zeff was in the range of 11.9-17.1. These TL materials have great potential to be introduced as new radiation dosimeters. 2013-12 Thesis http://eprints.utm.my/id/eprint/47937/ http://eprints.utm.my/id/eprint/47937/25/NurulAinMohamadMFS2013.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Science Faculty of Science
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic QC Physics
spellingShingle QC Physics
Mohamad Sharif, Nurul Ain
Effect of photon irradiation on the thermoluminescence response of optical fibres
description Studies on silica glass (SiO2) optical fibre as thermoluminescent materials for medical radiation dosimetry have been conducted by several research groups. This study focuses on the thermoluminescence (TL) response, linearity, sensitivity, dose response, fading, reproducibility and minimum detectable dose of 12 optical fibres sample namely Ge (A) Batch 1, 2 and 3, Ge (B), Multi Photonic Crystal Fibre (MPCF, 220 µm), Multi Photonic Crystal Fibre (MPCF, 2 mm), photonic crystal fibres (PCF), Dummy Flat Fibre (DFF), Flat fiber, Photosensitive Flat Fibre (PFF), Erbium (Er) and Aluminium/ Thulium (Al + Tm) doped optical fibre. A comparison was performed with TLD-100 (chips) to obtain the best TL response among the samples. Irradiation were performed with 6 and 10 MV photons covering the dose range of 1 Gy to 4 Gy by using linear accelerator machine Elekta SynergyTM at Pantai Hospital, Kuala Lumpur and Varian Model 2100C linear accelerator at University Malaya Medical Centre (UMMC). The comparisons of TL response with different model linear accelerators involved in this research were also performed. The results show that the highest sensitivity was obtained by using TLD-100, followed by PFF, Flat, Ge (A) Batch 1, MPCF (2 mm), Ge (A) Batch 3, Ge (A) Batch 2, DFF, Al+Tm, Ge (B), Er, MPCF (220 µm) and PCF. The fading of 5 optical fibres Ge (A) Batch 1, PFF, Er, Flat Fibre and PCF were determined and the loss of the TL signal for these TL materials were 10%, 29%, 30%, 30% and 43%, respectively. The dopant concentrations of Ge (A) Batch 1, Ge (B) and Er were found to be in the range of 0.03-0.72 mol % while the Zeff was in the range of 11.9-17.1. These TL materials have great potential to be introduced as new radiation dosimeters.
format Thesis
qualification_level Master's degree
author Mohamad Sharif, Nurul Ain
author_facet Mohamad Sharif, Nurul Ain
author_sort Mohamad Sharif, Nurul Ain
title Effect of photon irradiation on the thermoluminescence response of optical fibres
title_short Effect of photon irradiation on the thermoluminescence response of optical fibres
title_full Effect of photon irradiation on the thermoluminescence response of optical fibres
title_fullStr Effect of photon irradiation on the thermoluminescence response of optical fibres
title_full_unstemmed Effect of photon irradiation on the thermoluminescence response of optical fibres
title_sort effect of photon irradiation on the thermoluminescence response of optical fibres
granting_institution Universiti Teknologi Malaysia, Faculty of Science
granting_department Faculty of Science
publishDate 2013
url http://eprints.utm.my/id/eprint/47937/25/NurulAinMohamadMFS2013.pdf
_version_ 1747817267940294656