Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil

High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes...

Full description

Saved in:
Bibliographic Details
Main Author: Hameed, Ahmed Majid
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/48710/25/AhmedMajidHameedMFKE2014.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.48710
record_format uketd_dc
spelling my-utm-ep.487102020-06-18T00:55:02Z Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil 2014-06 Hameed, Ahmed Majid TK Electrical engineering. Electronics Nuclear engineering High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes gradual deterioration of the insulating materials, sometimes over a period of several years, leading perhaps to eventual failure. Detecting PD in power transformers is vital both in industries and utilities to avoid damage of high-voltage equipment. The objectives for this thesis are: To detect and analysis the PD activity using acoustic sensor (piezoelectric sensor) and capacitive sensor in natural palm-oil and to compare the sensitivity of the two sensors. The capacitive sensor and PZT sensors were immersed in palm oil tank fitted with two steel electrodes which were connected to range of high voltage (0-15KV) from high voltage source, the detecting signal that gained by the acoustic and electric sensors would pass through high pass filter to eliminate the noise range below 100-KHz then it is connected to the oscilloscope by wiring connections means. These data will evaluate in time and frequency domain by using analyzing software program (Origin-Pro). The conclusion that can acquire from this software and from the experimental lap results shown impressive characteristic for the PD detection and recommend the both sensors as a good tools for monitor and assessment the insulation condition when the discharge emission occur. 2014-06 Thesis http://eprints.utm.my/id/eprint/48710/ http://eprints.utm.my/id/eprint/48710/25/AhmedMajidHameedMFKE2014.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:87872 masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Hameed, Ahmed Majid
Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil
description High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes gradual deterioration of the insulating materials, sometimes over a period of several years, leading perhaps to eventual failure. Detecting PD in power transformers is vital both in industries and utilities to avoid damage of high-voltage equipment. The objectives for this thesis are: To detect and analysis the PD activity using acoustic sensor (piezoelectric sensor) and capacitive sensor in natural palm-oil and to compare the sensitivity of the two sensors. The capacitive sensor and PZT sensors were immersed in palm oil tank fitted with two steel electrodes which were connected to range of high voltage (0-15KV) from high voltage source, the detecting signal that gained by the acoustic and electric sensors would pass through high pass filter to eliminate the noise range below 100-KHz then it is connected to the oscilloscope by wiring connections means. These data will evaluate in time and frequency domain by using analyzing software program (Origin-Pro). The conclusion that can acquire from this software and from the experimental lap results shown impressive characteristic for the PD detection and recommend the both sensors as a good tools for monitor and assessment the insulation condition when the discharge emission occur.
format Thesis
qualification_level Master's degree
author Hameed, Ahmed Majid
author_facet Hameed, Ahmed Majid
author_sort Hameed, Ahmed Majid
title Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil
title_short Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil
title_full Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil
title_fullStr Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil
title_full_unstemmed Comparison between piezoelectric and capacitive sensors for PD detection and signal monitoring in palm oil
title_sort comparison between piezoelectric and capacitive sensors for pd detection and signal monitoring in palm oil
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2014
url http://eprints.utm.my/id/eprint/48710/25/AhmedMajidHameedMFKE2014.pdf
_version_ 1747817456869572608